使用磁性生物偶联物的横向流动试验增强CYFRA 21-1检测的分析性能:磁性和光学配准的整合和比较。

IF 4.9 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL Biosensors-Basel Pub Date : 2024-12-11 DOI:10.3390/bios14120607
Artemiy M Skirda, Alexey V Orlov, Juri A Malkerov, Sergey L Znoyko, Alexandra S Rakitina, Petr I Nikitin
{"title":"使用磁性生物偶联物的横向流动试验增强CYFRA 21-1检测的分析性能:磁性和光学配准的整合和比较。","authors":"Artemiy M Skirda, Alexey V Orlov, Juri A Malkerov, Sergey L Znoyko, Alexandra S Rakitina, Petr I Nikitin","doi":"10.3390/bios14120607","DOIUrl":null,"url":null,"abstract":"<p><p>A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"14 12","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11674727/pdf/","citationCount":"0","resultStr":"{\"title\":\"Enhanced Analytical Performance in CYFRA 21-1 Detection Using Lateral Flow Assay with Magnetic Bioconjugates: Integration and Comparison of Magnetic and Optical Registration.\",\"authors\":\"Artemiy M Skirda, Alexey V Orlov, Juri A Malkerov, Sergey L Znoyko, Alexandra S Rakitina, Petr I Nikitin\",\"doi\":\"10.3390/bios14120607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.</p>\",\"PeriodicalId\":48608,\"journal\":{\"name\":\"Biosensors-Basel\",\"volume\":\"14 12\",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11674727/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors-Basel\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bios14120607\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios14120607","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种开发检测CYFRA 21-1(细胞角蛋白19片段,上皮源性癌症的分子生物标志物)的侧流分析(LFAs)的新方法。采用磁性生物偶联物(MBCs)结合先进的光学和磁性工具优化检测条件。该方法集成了诸如无标记光谱相位干涉测量、比色检测和使用磁颗粒定量(MPQ)技术的超灵敏磁强计等技术。在LFA应用中,首次对基于mpq的检测方法和基于比色法的检测方法进行了比较,并证明了其优越的分析性能。MPQ法检测限为0.9 pg/mL,光学法检测限为2.9 pg/mL。这项研究表明,MPQ可以消除信号饱和,提高灵敏度(校准曲线的斜率),并将检测信号的动态范围扩大19倍。光学和磁检测结果可与最好的实验室检测相媲美,并具有20分钟分析持续时间和LFA格式便利的附加优点。该方法在人血清和人工唾液中均有效,回收率高。所提出的方法提供了快速可靠的分子生物标志物检测,并具有重大的即时诊断潜力,特别是在资源有限的环境中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Enhanced Analytical Performance in CYFRA 21-1 Detection Using Lateral Flow Assay with Magnetic Bioconjugates: Integration and Comparison of Magnetic and Optical Registration.

A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
期刊最新文献
A Novel Aggregation-Induced Emission-Based Electrochemiluminescence Aptamer Sensor Utilizing Red-Emissive Sulfur Quantum Dots for Rapid and Sensitive Malathion Detection. Is Breath Best? A Systematic Review on the Accuracy and Utility of Nanotechnology Based Breath Analysis of Ketones in Type 1 Diabetes. Sensitive Detection of Biomarker in Gingival Crevicular Fluid Based on Enhanced Electrochemiluminescence by Nanochannel-Confined Co3O4 Nanocatalyst. Potential of Zinc Oxide Nanostructures in Biosensor Application. Application of PS2M Aptamer as Receptor Layer for Electrochemical Detection of Lead Ions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1