Kenny Do, Kurtis Young, Eric Kawana, Jo-Lawrence Bigcas
{"title":"联合超声和双极剪切器与其他能量型耳鼻喉科设备的比较:系统综述和荟萃分析。","authors":"Kenny Do, Kurtis Young, Eric Kawana, Jo-Lawrence Bigcas","doi":"10.1177/15533506241313171","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The Thunderbeat (TB) is a new surgical device that combines ultrasonic and bipolar energy. The objective of this study is to examine how the combined ultrasonic and bipolar shears affect surgical outcomes when compared to other methods.</p><p><strong>Data sources and review methods: </strong>Using the PRISMA guidelines, the researchers used broad search terms in PubMed, Embase, and Web of Science, which produced a total of 2823 initial results, with years ranging from 1955 to June 2024. After applying inclusion and exclusion criteria, 8 final studies were included in this systematic review and meta-analysis.</p><p><strong>Results: </strong>This meta-analysis analyzes energy-based devices used on patients into 2 major groups: (1) thyroidectomy group and (2) neck dissection group. The researchers found that the use of the TB in thyroidectomies reduces operative time when compared to the Harmonic scalpel (HS) and Ligasure (LS). The pooled mean difference in thyroidectomy operation time for the TB vs HS was -5.77 min (95% CI: -11.07 to -.48, <i>P</i>-value: .03) and for the TB vs LS was -4.41 min (95% CI: -8.86 to .04, <i>P</i>-value: .05). We also found reduced operative time with the use of the TB vs standard electrocautery for neck dissection, where the mean difference was -39.76 min (95% CI: -63.00 to -16.51, <i>P</i>-value: .00). No significant differences were seen in blood loss or postoperative complications when comparing TB to other methods.</p><p><strong>Conclusion: </strong>This meta-analysis demonstrated that TB can be equivalent to other energy-based devices and shows potential advantages over traditional electrocautery.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":" ","pages":"15533506241313171"},"PeriodicalIF":1.2000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Comparison Between Combined Ultrasonic and Bipolar Shears to Other Energy-Based Devices in Otolaryngology: A Systematic Review and Meta-Analysis.\",\"authors\":\"Kenny Do, Kurtis Young, Eric Kawana, Jo-Lawrence Bigcas\",\"doi\":\"10.1177/15533506241313171\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The Thunderbeat (TB) is a new surgical device that combines ultrasonic and bipolar energy. The objective of this study is to examine how the combined ultrasonic and bipolar shears affect surgical outcomes when compared to other methods.</p><p><strong>Data sources and review methods: </strong>Using the PRISMA guidelines, the researchers used broad search terms in PubMed, Embase, and Web of Science, which produced a total of 2823 initial results, with years ranging from 1955 to June 2024. After applying inclusion and exclusion criteria, 8 final studies were included in this systematic review and meta-analysis.</p><p><strong>Results: </strong>This meta-analysis analyzes energy-based devices used on patients into 2 major groups: (1) thyroidectomy group and (2) neck dissection group. The researchers found that the use of the TB in thyroidectomies reduces operative time when compared to the Harmonic scalpel (HS) and Ligasure (LS). The pooled mean difference in thyroidectomy operation time for the TB vs HS was -5.77 min (95% CI: -11.07 to -.48, <i>P</i>-value: .03) and for the TB vs LS was -4.41 min (95% CI: -8.86 to .04, <i>P</i>-value: .05). We also found reduced operative time with the use of the TB vs standard electrocautery for neck dissection, where the mean difference was -39.76 min (95% CI: -63.00 to -16.51, <i>P</i>-value: .00). No significant differences were seen in blood loss or postoperative complications when comparing TB to other methods.</p><p><strong>Conclusion: </strong>This meta-analysis demonstrated that TB can be equivalent to other energy-based devices and shows potential advantages over traditional electrocautery.</p>\",\"PeriodicalId\":22095,\"journal\":{\"name\":\"Surgical Innovation\",\"volume\":\" \",\"pages\":\"15533506241313171\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-01-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Innovation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15533506241313171\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506241313171","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
A Comparison Between Combined Ultrasonic and Bipolar Shears to Other Energy-Based Devices in Otolaryngology: A Systematic Review and Meta-Analysis.
Objective: The Thunderbeat (TB) is a new surgical device that combines ultrasonic and bipolar energy. The objective of this study is to examine how the combined ultrasonic and bipolar shears affect surgical outcomes when compared to other methods.
Data sources and review methods: Using the PRISMA guidelines, the researchers used broad search terms in PubMed, Embase, and Web of Science, which produced a total of 2823 initial results, with years ranging from 1955 to June 2024. After applying inclusion and exclusion criteria, 8 final studies were included in this systematic review and meta-analysis.
Results: This meta-analysis analyzes energy-based devices used on patients into 2 major groups: (1) thyroidectomy group and (2) neck dissection group. The researchers found that the use of the TB in thyroidectomies reduces operative time when compared to the Harmonic scalpel (HS) and Ligasure (LS). The pooled mean difference in thyroidectomy operation time for the TB vs HS was -5.77 min (95% CI: -11.07 to -.48, P-value: .03) and for the TB vs LS was -4.41 min (95% CI: -8.86 to .04, P-value: .05). We also found reduced operative time with the use of the TB vs standard electrocautery for neck dissection, where the mean difference was -39.76 min (95% CI: -63.00 to -16.51, P-value: .00). No significant differences were seen in blood loss or postoperative complications when comparing TB to other methods.
Conclusion: This meta-analysis demonstrated that TB can be equivalent to other energy-based devices and shows potential advantages over traditional electrocautery.
期刊介绍:
Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).