基于全析因设计的液相色谱法评价干粉吸入中布地奈德和富马酸福莫特罗的杂质含量。

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS Biomedical Chromatography Pub Date : 2025-01-10 DOI:10.1002/bmc.6062
Lova Gani Raju Bandaru, Naresh Konduru, Leela Prasad Kowtharapu, Rambabu Gundla, Phani Raja Kanuparthy, Naresh Kumar Katari
{"title":"基于全析因设计的液相色谱法评价干粉吸入中布地奈德和富马酸福莫特罗的杂质含量。","authors":"Lova Gani Raju Bandaru,&nbsp;Naresh Konduru,&nbsp;Leela Prasad Kowtharapu,&nbsp;Rambabu Gundla,&nbsp;Phani Raja Kanuparthy,&nbsp;Naresh Kumar Katari","doi":"10.1002/bmc.6062","DOIUrl":null,"url":null,"abstract":"<p>A simple LC method has been developed and validated for estimating budesonide (epimer B + A) and formoterol fumarate dihydrate in dry powder inhalation. The development results of this study make it very significant. The degradation and process impurities in EP and ChP were identified in addition to budesonide and formoterol fumarate. As of yet, no one has reported all impurities using a single method. It is a unique research because it analyzes APSD (Aerodynamic Particle Size Distribution), DDU (Delivered Dose Uniformity), BU (Blend Uniformity), Assay, and cleaning test samples. It enhances the quality of medicine and separates all organic impurities and isomers through a suitable stationary phase (YMC-Pack Pro C18, 150 × 4.6 mm × 3 μm). We optimized the chromatographic conditions: Injection volume was 20 μL, and flow rate was 1.0 mL/min. The wavelength was optimized at 220 nm. After experimental and validation results. An example is A, which contains sodium dihydrogen orthophosphate monohydrate, sodium 1-decane sulfonate, adjusted pH 3.0, and acetonitrile at a ratio of 80:20 (v/v), and B, which contains pH 3.0 buffer and acetonitrile at a ratio of 20:80 (v/v) respectively. In addition to being optimized, the test method was validated according to ICH Q2(R2).</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 2","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11718425/pdf/","citationCount":"0","resultStr":"{\"title\":\"Unique Research for Developing a Full Factorial Design Evaluated Liquid Chromatography Technique for Estimating Budesonide and Formoterol Fumarate Dihydrate in the Presence of Specified and Degradation Impurities in Dry Powder Inhalation\",\"authors\":\"Lova Gani Raju Bandaru,&nbsp;Naresh Konduru,&nbsp;Leela Prasad Kowtharapu,&nbsp;Rambabu Gundla,&nbsp;Phani Raja Kanuparthy,&nbsp;Naresh Kumar Katari\",\"doi\":\"10.1002/bmc.6062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A simple LC method has been developed and validated for estimating budesonide (epimer B + A) and formoterol fumarate dihydrate in dry powder inhalation. The development results of this study make it very significant. The degradation and process impurities in EP and ChP were identified in addition to budesonide and formoterol fumarate. As of yet, no one has reported all impurities using a single method. It is a unique research because it analyzes APSD (Aerodynamic Particle Size Distribution), DDU (Delivered Dose Uniformity), BU (Blend Uniformity), Assay, and cleaning test samples. It enhances the quality of medicine and separates all organic impurities and isomers through a suitable stationary phase (YMC-Pack Pro C18, 150 × 4.6 mm × 3 μm). We optimized the chromatographic conditions: Injection volume was 20 μL, and flow rate was 1.0 mL/min. The wavelength was optimized at 220 nm. After experimental and validation results. An example is A, which contains sodium dihydrogen orthophosphate monohydrate, sodium 1-decane sulfonate, adjusted pH 3.0, and acetonitrile at a ratio of 80:20 (v/v), and B, which contains pH 3.0 buffer and acetonitrile at a ratio of 20:80 (v/v) respectively. In addition to being optimized, the test method was validated according to ICH Q2(R2).</p>\",\"PeriodicalId\":8861,\"journal\":{\"name\":\"Biomedical Chromatography\",\"volume\":\"39 2\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11718425/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Chromatography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bmc.6062\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.6062","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

建立了一种简便的液相色谱法,用于测定干粉吸入中布地奈德(B + A)和富马酸福莫特罗的含量。本研究的发展成果具有重要意义。除布地奈德和富马酸福莫特罗外,还对EP和ChP中的降解和工艺杂质进行了鉴定。到目前为止,还没有人用一种方法报告所有杂质。这是一项独特的研究,因为它分析了APSD(空气动力学粒径分布)、DDU(输送剂量均匀性)、BU(混合均匀性)、分析和清洁测试样品。它通过合适的固定相(YMC-Pack Pro C18, 150 × 4.6 mm × 3 μm)分离所有有机杂质和异构体,提高了药物质量。优化色谱条件:进样量为20 μL,流速为1.0 mL/min。优化波长为220 nm。经过实验和验证结果。例如,A中含有一水合物正磷酸二氢钠、调整pH为3.0的1-癸烷磺酸钠和乙腈的比例为80:20 (v/v); B中含有pH为3.0的缓冲液和乙腈的比例为20:80 (v/v)。除进行优化外,还按照ICH Q2(R2)对试验方法进行验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Unique Research for Developing a Full Factorial Design Evaluated Liquid Chromatography Technique for Estimating Budesonide and Formoterol Fumarate Dihydrate in the Presence of Specified and Degradation Impurities in Dry Powder Inhalation

A simple LC method has been developed and validated for estimating budesonide (epimer B + A) and formoterol fumarate dihydrate in dry powder inhalation. The development results of this study make it very significant. The degradation and process impurities in EP and ChP were identified in addition to budesonide and formoterol fumarate. As of yet, no one has reported all impurities using a single method. It is a unique research because it analyzes APSD (Aerodynamic Particle Size Distribution), DDU (Delivered Dose Uniformity), BU (Blend Uniformity), Assay, and cleaning test samples. It enhances the quality of medicine and separates all organic impurities and isomers through a suitable stationary phase (YMC-Pack Pro C18, 150 × 4.6 mm × 3 μm). We optimized the chromatographic conditions: Injection volume was 20 μL, and flow rate was 1.0 mL/min. The wavelength was optimized at 220 nm. After experimental and validation results. An example is A, which contains sodium dihydrogen orthophosphate monohydrate, sodium 1-decane sulfonate, adjusted pH 3.0, and acetonitrile at a ratio of 80:20 (v/v), and B, which contains pH 3.0 buffer and acetonitrile at a ratio of 20:80 (v/v) respectively. In addition to being optimized, the test method was validated according to ICH Q2(R2).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
期刊最新文献
Issue Information Quantification of Pectolinarin in Rat Plasma Using UPLC-MS/MS and Its Pharmacokinetic Analysis A Sensitive and Selective LC–MS/MS-ESI Method for the Quantitation of Metabolites M9, M12, and M20 of Bexicaserin in Human Plasma and Urine Matrices Study on Quality Evaluation of Er Miao San Based on HPLC Fingerprinting Combined With Multi-Indicator Content Determination Metabolomic Study of the Analgesic Effect of Dalbergia hancei Benth (D. hancei) on Nociceptive Pain
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1