Changliang Luo, Huidong Wu, Wei Liu, Yuyan Luo, Yi Jie, Christina Zong-Hao Ma, Mansang Wong
{"title":"青少年特发性脊柱侧凸脊柱矫形器的生物力学:控制力的系统综述。","authors":"Changliang Luo, Huidong Wu, Wei Liu, Yuyan Luo, Yi Jie, Christina Zong-Hao Ma, Mansang Wong","doi":"10.3390/bioengineering11121242","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Orthotic treatment is a well-acknowledged conservative treatment for moderate adolescent idiopathic scoliosis (AIS). The efficacy of this treatment is significantly determined by the forces applied to the bodies of patients. However, there is uncertainty regarding the optimal force levels that should be applied to the patient's torso by spinal orthosis. This study aims to identify reference values for the controlling forces in AIS management.</p><p><strong>Methods: </strong>A comprehensive literature search was performed in five databases (PubMed, Scopus, Cochrane Library, CINAHL, and Web of Science). Only studies written in English and covering the force/pressure measurements of spinal orthosis for the treatment of AIS were included, without publication date restrictions. The methodological index for non-randomized studies (MINORS) was employed for the methodological quality assessment, and force measurements were standardized to pressure in kilopascals (kPa) for comparison.</p><p><strong>Results: </strong>From the initial 10,452 records, 10 studies were admitted for the final analysis. All the included studies reported the interface pressure between the thoracic (T) pad and patient's trunk, and seven studies evaluated the pressure from the thoracolumbar/lumbar (TL/L) pad. These studies used different pressure sensors or transducers with the range from 5.6 to 82.5 kPa for the T pads, and 4.8 to 85.1 kPa for the TL/L pads. Four studies reported strap tensions of 26.8 to 60.4 N. Higher strap tension was correlated with increased interface pressure (r = 0.84).</p><p><strong>Conclusion: </strong>The mean strap tension was 42.5 N, the median interface pressure of the T pads was 8.75 kPa, and the median pressure of TL/L regions was 7.11 kPa without the outliers. The findings provide a baseline value for designing adjustable straps and strategically distributing pressure in orthoses.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"11 12","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11673803/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Biomechanics of Spinal Orthoses for Adolescent Idiopathic Scoliosis: A Systematic Review of the Controlling Forces.\",\"authors\":\"Changliang Luo, Huidong Wu, Wei Liu, Yuyan Luo, Yi Jie, Christina Zong-Hao Ma, Mansang Wong\",\"doi\":\"10.3390/bioengineering11121242\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Orthotic treatment is a well-acknowledged conservative treatment for moderate adolescent idiopathic scoliosis (AIS). The efficacy of this treatment is significantly determined by the forces applied to the bodies of patients. However, there is uncertainty regarding the optimal force levels that should be applied to the patient's torso by spinal orthosis. This study aims to identify reference values for the controlling forces in AIS management.</p><p><strong>Methods: </strong>A comprehensive literature search was performed in five databases (PubMed, Scopus, Cochrane Library, CINAHL, and Web of Science). Only studies written in English and covering the force/pressure measurements of spinal orthosis for the treatment of AIS were included, without publication date restrictions. The methodological index for non-randomized studies (MINORS) was employed for the methodological quality assessment, and force measurements were standardized to pressure in kilopascals (kPa) for comparison.</p><p><strong>Results: </strong>From the initial 10,452 records, 10 studies were admitted for the final analysis. All the included studies reported the interface pressure between the thoracic (T) pad and patient's trunk, and seven studies evaluated the pressure from the thoracolumbar/lumbar (TL/L) pad. These studies used different pressure sensors or transducers with the range from 5.6 to 82.5 kPa for the T pads, and 4.8 to 85.1 kPa for the TL/L pads. Four studies reported strap tensions of 26.8 to 60.4 N. Higher strap tension was correlated with increased interface pressure (r = 0.84).</p><p><strong>Conclusion: </strong>The mean strap tension was 42.5 N, the median interface pressure of the T pads was 8.75 kPa, and the median pressure of TL/L regions was 7.11 kPa without the outliers. The findings provide a baseline value for designing adjustable straps and strategically distributing pressure in orthoses.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":\"11 12\",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11673803/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering11121242\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11121242","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
The Biomechanics of Spinal Orthoses for Adolescent Idiopathic Scoliosis: A Systematic Review of the Controlling Forces.
Background: Orthotic treatment is a well-acknowledged conservative treatment for moderate adolescent idiopathic scoliosis (AIS). The efficacy of this treatment is significantly determined by the forces applied to the bodies of patients. However, there is uncertainty regarding the optimal force levels that should be applied to the patient's torso by spinal orthosis. This study aims to identify reference values for the controlling forces in AIS management.
Methods: A comprehensive literature search was performed in five databases (PubMed, Scopus, Cochrane Library, CINAHL, and Web of Science). Only studies written in English and covering the force/pressure measurements of spinal orthosis for the treatment of AIS were included, without publication date restrictions. The methodological index for non-randomized studies (MINORS) was employed for the methodological quality assessment, and force measurements were standardized to pressure in kilopascals (kPa) for comparison.
Results: From the initial 10,452 records, 10 studies were admitted for the final analysis. All the included studies reported the interface pressure between the thoracic (T) pad and patient's trunk, and seven studies evaluated the pressure from the thoracolumbar/lumbar (TL/L) pad. These studies used different pressure sensors or transducers with the range from 5.6 to 82.5 kPa for the T pads, and 4.8 to 85.1 kPa for the TL/L pads. Four studies reported strap tensions of 26.8 to 60.4 N. Higher strap tension was correlated with increased interface pressure (r = 0.84).
Conclusion: The mean strap tension was 42.5 N, the median interface pressure of the T pads was 8.75 kPa, and the median pressure of TL/L regions was 7.11 kPa without the outliers. The findings provide a baseline value for designing adjustable straps and strategically distributing pressure in orthoses.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering