微振动辅助双层螺旋微针快速提取真皮间质液用于葡萄糖的微创检测。

IF 7.3 1区 工程技术 Q1 INSTRUMENTS & INSTRUMENTATION Microsystems & Nanoengineering Pub Date : 2025-01-08 DOI:10.1038/s41378-024-00850-x
Khaled Mohammed Saifullah, Asim Mushtaq, Pouria Azarikhah, Philip D Prewett, Graham J Davies, Zahra Faraji Rad
{"title":"微振动辅助双层螺旋微针快速提取真皮间质液用于葡萄糖的微创检测。","authors":"Khaled Mohammed Saifullah, Asim Mushtaq, Pouria Azarikhah, Philip D Prewett, Graham J Davies, Zahra Faraji Rad","doi":"10.1038/s41378-024-00850-x","DOIUrl":null,"url":null,"abstract":"<p><p>Various hydrogels have been explored to create minimally invasive microneedles (MNs) to extract interstitial fluid (ISF). However, current methods are time-consuming and typically require 10-15 min to extract 3-5 mg of ISF. This study introduces two spiral-shaped swellable MN arrays: one made of gelatin methacryloyl (GelMA) and polyvinyl alcohol (PVA), and the other incorporating a combination of PVA, polyvinylpyrrolidone (PVP), and hyaluronic acid (HA) for fast ISF extraction. These MN arrays demonstrated a rapid swelling ratio of 560 ± 79.6% and 370 ± 34.1% in artificial ISF within 10 min, respectively. Additionally, this study proposes a novel method that combines MNs with a custom-designed Arduino-based applicator vibrating at frequency ranges (50-100 Hz) to improve skin penetration efficiency, thereby enhancing the uptake of ISF in ex vivo. This dynamic combination enables GelMA/PVA MNs to rapidly uptake 6.41 ± 1.01 mg of ISF in just 5 min, while PVA/PVP/HA MNs extract 5.38 ± 0.77 mg of ISF within the same timeframe. To validate the capability of the MNs to recover glucose as the target biomarker, a mild heating procedure is used, followed by determining glucose concentration using a D-glucose content assay kit. The efficient extraction of ISF and glucose detection capabilities of the spiral MNs suggest their potential for rapid and minimally invasive biomarker sensing.</p>","PeriodicalId":18560,"journal":{"name":"Microsystems & Nanoengineering","volume":"11 1","pages":"3"},"PeriodicalIF":7.3000,"publicationDate":"2025-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11706973/pdf/","citationCount":"0","resultStr":"{\"title\":\"Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose.\",\"authors\":\"Khaled Mohammed Saifullah, Asim Mushtaq, Pouria Azarikhah, Philip D Prewett, Graham J Davies, Zahra Faraji Rad\",\"doi\":\"10.1038/s41378-024-00850-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Various hydrogels have been explored to create minimally invasive microneedles (MNs) to extract interstitial fluid (ISF). However, current methods are time-consuming and typically require 10-15 min to extract 3-5 mg of ISF. This study introduces two spiral-shaped swellable MN arrays: one made of gelatin methacryloyl (GelMA) and polyvinyl alcohol (PVA), and the other incorporating a combination of PVA, polyvinylpyrrolidone (PVP), and hyaluronic acid (HA) for fast ISF extraction. These MN arrays demonstrated a rapid swelling ratio of 560 ± 79.6% and 370 ± 34.1% in artificial ISF within 10 min, respectively. Additionally, this study proposes a novel method that combines MNs with a custom-designed Arduino-based applicator vibrating at frequency ranges (50-100 Hz) to improve skin penetration efficiency, thereby enhancing the uptake of ISF in ex vivo. This dynamic combination enables GelMA/PVA MNs to rapidly uptake 6.41 ± 1.01 mg of ISF in just 5 min, while PVA/PVP/HA MNs extract 5.38 ± 0.77 mg of ISF within the same timeframe. To validate the capability of the MNs to recover glucose as the target biomarker, a mild heating procedure is used, followed by determining glucose concentration using a D-glucose content assay kit. The efficient extraction of ISF and glucose detection capabilities of the spiral MNs suggest their potential for rapid and minimally invasive biomarker sensing.</p>\",\"PeriodicalId\":18560,\"journal\":{\"name\":\"Microsystems & Nanoengineering\",\"volume\":\"11 1\",\"pages\":\"3\"},\"PeriodicalIF\":7.3000,\"publicationDate\":\"2025-01-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11706973/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microsystems & Nanoengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1038/s41378-024-00850-x\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microsystems & Nanoengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1038/s41378-024-00850-x","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

各种水凝胶已被探索用于制造微创微针(MNs)来提取间质液(ISF)。然而,目前的方法是耗时的,通常需要10-15分钟提取3-5毫克的ISF。本研究介绍了两种螺旋形可膨胀MN阵列:一种是由明胶甲基丙烯酰(GelMA)和聚乙烯醇(PVA)组成的,另一种是由PVA、聚乙烯吡罗烷酮(PVP)和透明质酸(HA)组成的,用于快速提取ISF。这些MN阵列在人工ISF中10 min内的快速膨胀率分别为560±79.6%和370±34.1%。此外,本研究提出了一种新颖的方法,将MNs与定制设计的基于arduino的涂抹器结合在一起,在频率范围(50-100 Hz)振动,以提高皮肤渗透效率,从而增强体外对ISF的吸收。这种动态组合使GelMA/PVA MNs在5分钟内快速吸收6.41±1.01 mg ISF,而PVA/PVP/HA MNs在相同的时间内提取5.38±0.77 mg ISF。为了验证MNs回收葡萄糖作为目标生物标志物的能力,使用温和的加热程序,然后使用d -葡萄糖含量测定试剂盒测定葡萄糖浓度。螺旋MNs的高效提取ISF和葡萄糖检测能力表明它们具有快速和微创生物标志物传感的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose.

Various hydrogels have been explored to create minimally invasive microneedles (MNs) to extract interstitial fluid (ISF). However, current methods are time-consuming and typically require 10-15 min to extract 3-5 mg of ISF. This study introduces two spiral-shaped swellable MN arrays: one made of gelatin methacryloyl (GelMA) and polyvinyl alcohol (PVA), and the other incorporating a combination of PVA, polyvinylpyrrolidone (PVP), and hyaluronic acid (HA) for fast ISF extraction. These MN arrays demonstrated a rapid swelling ratio of 560 ± 79.6% and 370 ± 34.1% in artificial ISF within 10 min, respectively. Additionally, this study proposes a novel method that combines MNs with a custom-designed Arduino-based applicator vibrating at frequency ranges (50-100 Hz) to improve skin penetration efficiency, thereby enhancing the uptake of ISF in ex vivo. This dynamic combination enables GelMA/PVA MNs to rapidly uptake 6.41 ± 1.01 mg of ISF in just 5 min, while PVA/PVP/HA MNs extract 5.38 ± 0.77 mg of ISF within the same timeframe. To validate the capability of the MNs to recover glucose as the target biomarker, a mild heating procedure is used, followed by determining glucose concentration using a D-glucose content assay kit. The efficient extraction of ISF and glucose detection capabilities of the spiral MNs suggest their potential for rapid and minimally invasive biomarker sensing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microsystems & Nanoengineering
Microsystems & Nanoengineering Materials Science-Materials Science (miscellaneous)
CiteScore
12.00
自引率
3.80%
发文量
123
审稿时长
20 weeks
期刊介绍: Microsystems & Nanoengineering is a comprehensive online journal that focuses on the field of Micro and Nano Electro Mechanical Systems (MEMS and NEMS). It provides a platform for researchers to share their original research findings and review articles in this area. The journal covers a wide range of topics, from fundamental research to practical applications. Published by Springer Nature, in collaboration with the Aerospace Information Research Institute, Chinese Academy of Sciences, and with the support of the State Key Laboratory of Transducer Technology, it is an esteemed publication in the field. As an open access journal, it offers free access to its content, allowing readers from around the world to benefit from the latest developments in MEMS and NEMS.
期刊最新文献
A low-cost printed circuit board-based centrifugal microfluidic platform for dielectrophoresis. Fully automated in vivo screening system for multi-organ imaging and pharmaceutical evaluation. Controllable tip exposure of ultramicroelectrodes coated by diamond-like carbon via direct microplasma jet for enhanced stability and fidelity in single-cell recording. Theoretical and experimental investigations of the CMOS compatible Pirani gauges with a temperature compensation model. An intelligent humidity sensing system for human behavior recognition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1