比较使用心理物理阈值和全景电诱发复合动作电位(PECAPs)估计的耳蜗内神经健康的患者特异性差异。

IF 2.9 3区 医学 Q3 NEUROSCIENCES Jaro-Journal of the Association for Research in Otolaryngology Pub Date : 2025-02-01 Epub Date: 2025-01-08 DOI:10.1007/s10162-024-00972-z
Tommy Peng, Charlotte Garcia, Mica Haneman, Maureen J Shader, Robert P Carlyon, Colette M McKay
{"title":"比较使用心理物理阈值和全景电诱发复合动作电位(PECAPs)估计的耳蜗内神经健康的患者特异性差异。","authors":"Tommy Peng, Charlotte Garcia, Mica Haneman, Maureen J Shader, Robert P Carlyon, Colette M McKay","doi":"10.1007/s10162-024-00972-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences.</p><p><strong>Methods: </strong>Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study. We estimated the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the panoramic electrically evoked compound action potential method (PECAP). We hypothesised that: neural health estimated using both methods at single electrodes will be correlated at the participant level and the group level; and participants with larger variations in neural health along the electrode array will have poorer speech outcomes.</p><p><strong>Results: </strong>At the individual level, the two neural measures correlated significantly across electrodes (p < 0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant across-electrode correlation (R<sup>2</sup> = 0.111, p < 0.001). While a larger variation in neural measures estimated from psychophysical thresholds was associated with lower phoneme speech scores (R<sup>2</sup> = 0.499, p < 0.01), no significant association was found between variations in PECAP's neural health estimates and phoneme speech scores (R<sup>2</sup> = 0.082, p = 0.366).</p><p><strong>Conclusion: </strong>Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or the influence of factors arising more centrally than the auditory nerve.</p>","PeriodicalId":56283,"journal":{"name":"Jaro-Journal of the Association for Research in Otolaryngology","volume":" ","pages":"77-91"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11861486/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparing Patient-Specific Variations in Intra-Cochlear Neural Health Estimated Using Psychophysical Thresholds and Panoramic Electrically Evoked Compound Action Potentials (PECAPs).\",\"authors\":\"Tommy Peng, Charlotte Garcia, Mica Haneman, Maureen J Shader, Robert P Carlyon, Colette M McKay\",\"doi\":\"10.1007/s10162-024-00972-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences.</p><p><strong>Methods: </strong>Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study. We estimated the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the panoramic electrically evoked compound action potential method (PECAP). We hypothesised that: neural health estimated using both methods at single electrodes will be correlated at the participant level and the group level; and participants with larger variations in neural health along the electrode array will have poorer speech outcomes.</p><p><strong>Results: </strong>At the individual level, the two neural measures correlated significantly across electrodes (p < 0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant across-electrode correlation (R<sup>2</sup> = 0.111, p < 0.001). While a larger variation in neural measures estimated from psychophysical thresholds was associated with lower phoneme speech scores (R<sup>2</sup> = 0.499, p < 0.01), no significant association was found between variations in PECAP's neural health estimates and phoneme speech scores (R<sup>2</sup> = 0.082, p = 0.366).</p><p><strong>Conclusion: </strong>Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or the influence of factors arising more centrally than the auditory nerve.</p>\",\"PeriodicalId\":56283,\"journal\":{\"name\":\"Jaro-Journal of the Association for Research in Otolaryngology\",\"volume\":\" \",\"pages\":\"77-91\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11861486/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jaro-Journal of the Association for Research in Otolaryngology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10162-024-00972-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jaro-Journal of the Association for Research in Otolaryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10162-024-00972-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的:沿人工耳蜗电极阵列的神经存活变化导致听者的听力偏离位置,从而导致接受者的言语理解效果较差。因此,重要的是开发和比较临床可行的测试,以确定这些患者特异性的耳蜗内神经差异。方法:19例有人工耳蜗植入经验的患者(男9例,女10例)参加本研究。我们利用两种方法估计了一组有经验的成人植入物受者沿电极阵列的神经健康状况:双极与单极模式的心理物理检测阈值和全景电诱发复合动作电位方法(PECAP)之间的差异。我们假设:使用两种方法在单电极上估计的神经健康将在参与者水平和群体水平上相关;在电极阵列上,神经健康状况变化较大的参与者的语言表现也会较差。结果:在个体水平上,两种神经测量在电极上显著相关(p = 0.111, p = 0.499, p = 0.082, p = 0.366)。结论:我们的证据表明,这两种方法可能量化了一个共同的潜在神经基础,假设是沿人工耳蜗阵列的神经健康。这两种测量方法之间的差异可归因于用于引起反应的刺激率或响度的差异和/或比听觉神经更集中的因素的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparing Patient-Specific Variations in Intra-Cochlear Neural Health Estimated Using Psychophysical Thresholds and Panoramic Electrically Evoked Compound Action Potentials (PECAPs).

Purpose: Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlear neural differences.

Methods: Nineteen experienced cochlear implant recipients (9 males and 10 females) were recruited for this study. We estimated the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the panoramic electrically evoked compound action potential method (PECAP). We hypothesised that: neural health estimated using both methods at single electrodes will be correlated at the participant level and the group level; and participants with larger variations in neural health along the electrode array will have poorer speech outcomes.

Results: At the individual level, the two neural measures correlated significantly across electrodes (p < 0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant across-electrode correlation (R2 = 0.111, p < 0.001). While a larger variation in neural measures estimated from psychophysical thresholds was associated with lower phoneme speech scores (R2 = 0.499, p < 0.01), no significant association was found between variations in PECAP's neural health estimates and phoneme speech scores (R2 = 0.082, p = 0.366).

Conclusion: Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or the influence of factors arising more centrally than the auditory nerve.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
12.50%
发文量
57
审稿时长
6-12 weeks
期刊介绍: JARO is a peer-reviewed journal that publishes research findings from disciplines related to otolaryngology and communications sciences, including hearing, balance, speech and voice. JARO welcomes submissions describing experimental research that investigates the mechanisms underlying problems of basic and/or clinical significance. Authors are encouraged to familiarize themselves with the kinds of papers carried by JARO by looking at past issues. Clinical case studies and pharmaceutical screens are not likely to be considered unless they reveal underlying mechanisms. Methods papers are not encouraged unless they include significant new findings as well. Reviews will be published at the discretion of the editorial board; consult the editor-in-chief before submitting.
期刊最新文献
A Structural Equation Approach to Characterizing Growth and Nonlinearity Underlying Distortion Product Otoacoustic Emissions. Age-dependent Shifts in Spiral Ganglion Neuron Subtypes Are Associated with Interphase Gap-dependent Modulation of Electrically Evoked Compound Action Potentials in Mice. Bayesian Uncertainty Quantification for A Fractional-Order Model of the Human Ear. Development of the Surgical Implantation and Fixation of an Implanted Middle Ear Microphone, the "UmboMic," in Cadaveric Sheep. Spontaneous Calcium Signalling in the Developing Mammalian Cochlea.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1