人工耳蜗植入过程中实时记录的振幅和相位变化及其与术前和术后听力的关系。

IF 1.9 3区 医学 Q3 CLINICAL NEUROLOGY Otology & Neurotology Pub Date : 2025-01-30 DOI:10.1097/MAO.0000000000004420
Adrian Dalbert, Christofer Bester, Aaron Collins, Tayla Razmovski, Jean-Marc Gerard, Stephen O'Leary
{"title":"人工耳蜗植入过程中实时记录的振幅和相位变化及其与术前和术后听力的关系。","authors":"Adrian Dalbert, Christofer Bester, Aaron Collins, Tayla Razmovski, Jean-Marc Gerard, Stephen O'Leary","doi":"10.1097/MAO.0000000000004420","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing.</p><p><strong>Methods: </strong>Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were prospectively included. Real-time ECochG recordings were conducted via the cochlear implant. The difference curve (DIF) signal of the ECochG recordings was analyzed regarding alteration of the waveform, amplitude changes, and relative phase shifts during insertion.</p><p><strong>Results: </strong>Five subjects (56%) with FA and 13 (62%) with SA exhibited DIF signal drops in the early phase of the insertion. In subjects with FA, alterations of the DIF signal waveform in the early phase of the insertion occurred in 8 subjects (90%), whereas such changes were detectable in only 2 out of 21 subjects (10%) with SA ( p < 0.001). DIF signal drops with relative phase shifts of >0.7 radians but without alterations of the waveform occurred in 5 subjects (56%) with FA and 11 (52%) with SA. Such drops were associated with larger postoperative hearing losses than DIF signal drops without phase changes in both groups (FA: 43 versus 20 dB, p = 0.045; SA: 30 versus 14 dB, p = 0.001).</p><p><strong>Conclusion: </strong>Residual cochlear function in basal regions leads to alteration of the DIF signal waveform during insertion, probably not associated with cochlear injury. A decrease of the DIF signal amplitude with a simultaneous relative phase shift but no alteration of the waveform is associated with greater loss of residual hearing independent from the preoperative hearing.</p>","PeriodicalId":19732,"journal":{"name":"Otology & Neurotology","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Amplitude and Phase Changes in Electrocochleographic Real-Time Recordings During Cochlear Implantation and Its Relation to Pre- and Postoperative Hearing.\",\"authors\":\"Adrian Dalbert, Christofer Bester, Aaron Collins, Tayla Razmovski, Jean-Marc Gerard, Stephen O'Leary\",\"doi\":\"10.1097/MAO.0000000000004420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing.</p><p><strong>Methods: </strong>Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were prospectively included. Real-time ECochG recordings were conducted via the cochlear implant. The difference curve (DIF) signal of the ECochG recordings was analyzed regarding alteration of the waveform, amplitude changes, and relative phase shifts during insertion.</p><p><strong>Results: </strong>Five subjects (56%) with FA and 13 (62%) with SA exhibited DIF signal drops in the early phase of the insertion. In subjects with FA, alterations of the DIF signal waveform in the early phase of the insertion occurred in 8 subjects (90%), whereas such changes were detectable in only 2 out of 21 subjects (10%) with SA ( p < 0.001). DIF signal drops with relative phase shifts of >0.7 radians but without alterations of the waveform occurred in 5 subjects (56%) with FA and 11 (52%) with SA. Such drops were associated with larger postoperative hearing losses than DIF signal drops without phase changes in both groups (FA: 43 versus 20 dB, p = 0.045; SA: 30 versus 14 dB, p = 0.001).</p><p><strong>Conclusion: </strong>Residual cochlear function in basal regions leads to alteration of the DIF signal waveform during insertion, probably not associated with cochlear injury. A decrease of the DIF signal amplitude with a simultaneous relative phase shift but no alteration of the waveform is associated with greater loss of residual hearing independent from the preoperative hearing.</p>\",\"PeriodicalId\":19732,\"journal\":{\"name\":\"Otology & Neurotology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Otology & Neurotology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MAO.0000000000004420\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Otology & Neurotology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MAO.0000000000004420","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究的目的是将人工耳蜗植入过程中耳蜗电图(ECochG)记录的反应模式与术前和术后听力联系起来。方法:前瞻性纳入30例耳蜗植入前扁平(FA, n = 9)或倾斜(SA, n = 21)听音图的受试者。通过人工耳蜗进行实时ECochG记录。分析ECochG记录的差分曲线(DIF)信号在插入期间的波形变化、幅度变化和相对相移。结果:FA组5例(56%),SA组13例(62%)在插入早期出现DIF信号下降。在FA患者中,8名受试者(90%)在插入早期出现了DIF信号波形的改变,而在21名SA患者中只有2名(10%)检测到这种变化(p < 0.001)。FA组有5例(56%),SA组有11例(52%),DIF信号随相对相移而下降,但波形没有改变。在两组中,与无相位变化的DIF信号下降相比,这种下降与更大的术后听力损失相关(FA: 43对20 dB, p = 0.045;SA: 30 vs 14 dB, p = 0.001)。结论:基底区耳蜗功能的残留导致了植入时DIF信号波形的改变,可能与耳蜗损伤无关。DIF信号幅度下降,同时出现相对相移,但波形没有改变,与术前听力无关的残余听力损失更大有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Amplitude and Phase Changes in Electrocochleographic Real-Time Recordings During Cochlear Implantation and Its Relation to Pre- and Postoperative Hearing.

Background: The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing.

Methods: Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were prospectively included. Real-time ECochG recordings were conducted via the cochlear implant. The difference curve (DIF) signal of the ECochG recordings was analyzed regarding alteration of the waveform, amplitude changes, and relative phase shifts during insertion.

Results: Five subjects (56%) with FA and 13 (62%) with SA exhibited DIF signal drops in the early phase of the insertion. In subjects with FA, alterations of the DIF signal waveform in the early phase of the insertion occurred in 8 subjects (90%), whereas such changes were detectable in only 2 out of 21 subjects (10%) with SA ( p < 0.001). DIF signal drops with relative phase shifts of >0.7 radians but without alterations of the waveform occurred in 5 subjects (56%) with FA and 11 (52%) with SA. Such drops were associated with larger postoperative hearing losses than DIF signal drops without phase changes in both groups (FA: 43 versus 20 dB, p = 0.045; SA: 30 versus 14 dB, p = 0.001).

Conclusion: Residual cochlear function in basal regions leads to alteration of the DIF signal waveform during insertion, probably not associated with cochlear injury. A decrease of the DIF signal amplitude with a simultaneous relative phase shift but no alteration of the waveform is associated with greater loss of residual hearing independent from the preoperative hearing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Otology & Neurotology
Otology & Neurotology 医学-耳鼻喉科学
CiteScore
3.80
自引率
14.30%
发文量
509
审稿时长
3-6 weeks
期刊介绍: ​​​​​Otology & Neurotology publishes original articles relating to both clinical and basic science aspects of otology, neurotology, and cranial base surgery. As the foremost journal in its field, it has become the favored place for publishing the best of new science relating to the human ear and its diseases. The broadly international character of its contributing authors, editorial board, and readership provides the Journal its decidedly global perspective.
期刊最新文献
Impact of Perioperative Anticoagulation and Antiplatelet Therapy on Hearing Preservation Outcomes. Angiotensin-Receptor Blockers Prevent Vestibular Schwannoma-Associated Hearing Loss. Detection of Extracochlear Electrodes Using Electrical Field Imaging (EFI). Preclinical Study of a Minimally Invasive Cochlear Implant Device Based on 3D Printing of a Custom Guide. Long-Term Clinical Outcomes for Bone-Anchored Hearing Implants: 3-Year Comparison Between Minimally Invasive Ponto Surgery and the Linear Incision Technique With Tissue Preservation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.