H.-J. Tu , Q.-Q. Chen , X. Chen , J.-C. Tu , J.-T. Cao , F. Zhu , C.-H. Hu
{"title":"使用低剂量计算机断层扫描(CT)肠造影灌注成像定量评估克罗恩病的跨壁缓解:基于肠道微循环的单中心研究","authors":"H.-J. Tu , Q.-Q. Chen , X. Chen , J.-C. Tu , J.-T. Cao , F. Zhu , C.-H. Hu","doi":"10.1016/j.crad.2024.106786","DOIUrl":null,"url":null,"abstract":"<div><h3>AIM</h3><div>To assess transmural remission in patients with Crohn's disease using low-dose small bowel computed tomography (CT) perfusion scans.</div></div><div><h3>MATERIALS AND METHODS</h3><div>Forty six patients were divided into active and remission phases based on Crohn's Disease Activity Index (CDAI) and C-reactive protein (CRP). Dual-source CT enterography with low-dose perfusion scans was conducted to generate perfusion parameter maps, including blood flow (BF), blood volume (BV), time to peak (TTP), mean transit time (MTT), and permeability of surface (PS). We compared differences in perfusion parameter values of intestinal walls, mesenteric fat, and lymph nodes between two groups. Receiver operating characteristic (ROC) curves were plotted, and area under the curve (AUC), sensitivity, specificity, and cutoff values were calculated.</div></div><div><h3>RESULTS</h3><div>The BF, BV, TTP, MTT, and PS values of the intestinal wall were significantly higher in the active phase (P0.05). Additionally, lymph node BF and TTP displayed significant differences (P<0.01).</div></div><div><h3>CONCLUSION</h3><div>Dual-source CT enterography with low-dose perfusion scans enables quantitative assessment of Crohn's disease microcirculation in intestinal walls, mesenteric fat, and lymph nodes. These quantitative indicators provide strong diagnostic efficacy and offer insights into whether the disease is in transmural remission.</div></div>","PeriodicalId":10695,"journal":{"name":"Clinical radiology","volume":"81 ","pages":"Article 106786"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative assessment of transmural remission in Crohn's disease using low dose computed tomography (CT) enterography perfusion imaging: a single-centre study based on intestinal microcirculation\",\"authors\":\"H.-J. Tu , Q.-Q. Chen , X. Chen , J.-C. Tu , J.-T. Cao , F. Zhu , C.-H. Hu\",\"doi\":\"10.1016/j.crad.2024.106786\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>AIM</h3><div>To assess transmural remission in patients with Crohn's disease using low-dose small bowel computed tomography (CT) perfusion scans.</div></div><div><h3>MATERIALS AND METHODS</h3><div>Forty six patients were divided into active and remission phases based on Crohn's Disease Activity Index (CDAI) and C-reactive protein (CRP). Dual-source CT enterography with low-dose perfusion scans was conducted to generate perfusion parameter maps, including blood flow (BF), blood volume (BV), time to peak (TTP), mean transit time (MTT), and permeability of surface (PS). We compared differences in perfusion parameter values of intestinal walls, mesenteric fat, and lymph nodes between two groups. Receiver operating characteristic (ROC) curves were plotted, and area under the curve (AUC), sensitivity, specificity, and cutoff values were calculated.</div></div><div><h3>RESULTS</h3><div>The BF, BV, TTP, MTT, and PS values of the intestinal wall were significantly higher in the active phase (P0.05). Additionally, lymph node BF and TTP displayed significant differences (P<0.01).</div></div><div><h3>CONCLUSION</h3><div>Dual-source CT enterography with low-dose perfusion scans enables quantitative assessment of Crohn's disease microcirculation in intestinal walls, mesenteric fat, and lymph nodes. These quantitative indicators provide strong diagnostic efficacy and offer insights into whether the disease is in transmural remission.</div></div>\",\"PeriodicalId\":10695,\"journal\":{\"name\":\"Clinical radiology\",\"volume\":\"81 \",\"pages\":\"Article 106786\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0009926024006731\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0009926024006731","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Quantitative assessment of transmural remission in Crohn's disease using low dose computed tomography (CT) enterography perfusion imaging: a single-centre study based on intestinal microcirculation
AIM
To assess transmural remission in patients with Crohn's disease using low-dose small bowel computed tomography (CT) perfusion scans.
MATERIALS AND METHODS
Forty six patients were divided into active and remission phases based on Crohn's Disease Activity Index (CDAI) and C-reactive protein (CRP). Dual-source CT enterography with low-dose perfusion scans was conducted to generate perfusion parameter maps, including blood flow (BF), blood volume (BV), time to peak (TTP), mean transit time (MTT), and permeability of surface (PS). We compared differences in perfusion parameter values of intestinal walls, mesenteric fat, and lymph nodes between two groups. Receiver operating characteristic (ROC) curves were plotted, and area under the curve (AUC), sensitivity, specificity, and cutoff values were calculated.
RESULTS
The BF, BV, TTP, MTT, and PS values of the intestinal wall were significantly higher in the active phase (P0.05). Additionally, lymph node BF and TTP displayed significant differences (P<0.01).
CONCLUSION
Dual-source CT enterography with low-dose perfusion scans enables quantitative assessment of Crohn's disease microcirculation in intestinal walls, mesenteric fat, and lymph nodes. These quantitative indicators provide strong diagnostic efficacy and offer insights into whether the disease is in transmural remission.
期刊介绍:
Clinical Radiology is published by Elsevier on behalf of The Royal College of Radiologists. Clinical Radiology is an International Journal bringing you original research, editorials and review articles on all aspects of diagnostic imaging, including:
• Computed tomography
• Magnetic resonance imaging
• Ultrasonography
• Digital radiology
• Interventional radiology
• Radiography
• Nuclear medicine
Papers on radiological protection, quality assurance, audit in radiology and matters relating to radiological training and education are also included. In addition, each issue contains correspondence, book reviews and notices of forthcoming events.