Julie Oudkerk, Christelle Sanchez, Charlotte Grenade, Alain Vanheusden, Amélie Mainjot
{"title":"使用PICN CAD-CAM修复体对磨损牙列进行无创全口修复的一步无准备技术:一项长达9年的前瞻性和回顾性临床研究结果。","authors":"Julie Oudkerk, Christelle Sanchez, Charlotte Grenade, Alain Vanheusden, Amélie Mainjot","doi":"10.1016/j.dental.2024.12.016","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To report up to 9-year results of a prospective and retrospective study on non-invasive full-mouth rehabilitation of worn dentition with PICN CAD-CAM restorations using the One-Step No-Prep technique. The secondary objective is to evaluate the influence of restoration thickness on fracture of restorations.</p><p><strong>Methods: </strong>A total of 580 Vita Enamic restorations (218 anterior and 362 posterior; 260 monoblock (MO) and 320 multiColor (MC)) in 24 patients were clinically evaluated once a year (up 9 months to 9 years) according to FDI criteria. Patient data and prosthetic parameters were registered. The minimum thickness of restorations was measured in 15 patients.</p><p><strong>Results: </strong>The Kaplan-Meier survival rate of restorations at 9 years was 98.4 % (100 % for anterior and 96.7 % for posterior) and the success rate was 79.7 %, while the success rate excluding minor chipping requiring only polishing as failure was 86.7 %. Actually, minor chipping was the leading cause of failure and significantly more fractures were observed in the posterior region (9.2 times higher risk), particularly in the first and second molars or when the restoration thickness was less than 0.56 mm. Except for fracture, FDI evaluation showed clinically acceptable results for all restorations, mostly rated as excellent. Results remained consistent over time, including material luster and color, with no staining. MC showed superior esthetics compared to MO. Patient satisfaction was high.</p><p><strong>Significance: </strong>The One-Step No-Prep technique exhibits successful long-term outcomes, and PICN (hybrid ceramic) is an appropriate material for this non-invasive treatment of tooth wear. Nevertheless, the minimum thickness of posterior restorations should be 0.6 mm, particularly at occlusal contact points. MultiColor blocks are recommended for esthetics.</p>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":" ","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The One-step No-prep technique for non-invasive full-mouth rehabilitation of worn dentition using PICN CAD-CAM restorations: Up to 9-year results from a prospective and retrospective clinical study.\",\"authors\":\"Julie Oudkerk, Christelle Sanchez, Charlotte Grenade, Alain Vanheusden, Amélie Mainjot\",\"doi\":\"10.1016/j.dental.2024.12.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To report up to 9-year results of a prospective and retrospective study on non-invasive full-mouth rehabilitation of worn dentition with PICN CAD-CAM restorations using the One-Step No-Prep technique. The secondary objective is to evaluate the influence of restoration thickness on fracture of restorations.</p><p><strong>Methods: </strong>A total of 580 Vita Enamic restorations (218 anterior and 362 posterior; 260 monoblock (MO) and 320 multiColor (MC)) in 24 patients were clinically evaluated once a year (up 9 months to 9 years) according to FDI criteria. Patient data and prosthetic parameters were registered. The minimum thickness of restorations was measured in 15 patients.</p><p><strong>Results: </strong>The Kaplan-Meier survival rate of restorations at 9 years was 98.4 % (100 % for anterior and 96.7 % for posterior) and the success rate was 79.7 %, while the success rate excluding minor chipping requiring only polishing as failure was 86.7 %. Actually, minor chipping was the leading cause of failure and significantly more fractures were observed in the posterior region (9.2 times higher risk), particularly in the first and second molars or when the restoration thickness was less than 0.56 mm. Except for fracture, FDI evaluation showed clinically acceptable results for all restorations, mostly rated as excellent. Results remained consistent over time, including material luster and color, with no staining. MC showed superior esthetics compared to MO. Patient satisfaction was high.</p><p><strong>Significance: </strong>The One-Step No-Prep technique exhibits successful long-term outcomes, and PICN (hybrid ceramic) is an appropriate material for this non-invasive treatment of tooth wear. Nevertheless, the minimum thickness of posterior restorations should be 0.6 mm, particularly at occlusal contact points. MultiColor blocks are recommended for esthetics.</p>\",\"PeriodicalId\":298,\"journal\":{\"name\":\"Dental Materials\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1016/j.dental.2024.12.016\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.dental.2024.12.016","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
The One-step No-prep technique for non-invasive full-mouth rehabilitation of worn dentition using PICN CAD-CAM restorations: Up to 9-year results from a prospective and retrospective clinical study.
Objectives: To report up to 9-year results of a prospective and retrospective study on non-invasive full-mouth rehabilitation of worn dentition with PICN CAD-CAM restorations using the One-Step No-Prep technique. The secondary objective is to evaluate the influence of restoration thickness on fracture of restorations.
Methods: A total of 580 Vita Enamic restorations (218 anterior and 362 posterior; 260 monoblock (MO) and 320 multiColor (MC)) in 24 patients were clinically evaluated once a year (up 9 months to 9 years) according to FDI criteria. Patient data and prosthetic parameters were registered. The minimum thickness of restorations was measured in 15 patients.
Results: The Kaplan-Meier survival rate of restorations at 9 years was 98.4 % (100 % for anterior and 96.7 % for posterior) and the success rate was 79.7 %, while the success rate excluding minor chipping requiring only polishing as failure was 86.7 %. Actually, minor chipping was the leading cause of failure and significantly more fractures were observed in the posterior region (9.2 times higher risk), particularly in the first and second molars or when the restoration thickness was less than 0.56 mm. Except for fracture, FDI evaluation showed clinically acceptable results for all restorations, mostly rated as excellent. Results remained consistent over time, including material luster and color, with no staining. MC showed superior esthetics compared to MO. Patient satisfaction was high.
Significance: The One-Step No-Prep technique exhibits successful long-term outcomes, and PICN (hybrid ceramic) is an appropriate material for this non-invasive treatment of tooth wear. Nevertheless, the minimum thickness of posterior restorations should be 0.6 mm, particularly at occlusal contact points. MultiColor blocks are recommended for esthetics.
期刊介绍:
Dental Materials publishes original research, review articles, and short communications.
Academy of Dental Materials members click here to register for free access to Dental Materials online.
The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology.
Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.