用液晶显示器补偿相衬显微镜中的半月板效应用于自适应聚光镜环移。

IF 2 3区 工程技术 Q2 ANATOMY & MORPHOLOGY Microscopy Research and Technique Pub Date : 2025-01-17 DOI:10.1002/jemt.24808
Florian Nienhaus, Finn Burkhardt, Niels König, Robert H Schmitt
{"title":"用液晶显示器补偿相衬显微镜中的半月板效应用于自适应聚光镜环移。","authors":"Florian Nienhaus, Finn Burkhardt, Niels König, Robert H Schmitt","doi":"10.1002/jemt.24808","DOIUrl":null,"url":null,"abstract":"<p><p>The meniscus effect in cell culture vessels limits the observable areas with phase contrast microscopy. For meniscus effect compensation in microtiter plates (MTPs), we present a method using an LCD to replace the fixed condenser annulus, which enables adaptive annulus shifting based on image analysis. This approach led to an increase in phase contrast area by a factor of 8.3. Utilizing a standard phase contrast microscope, we substituted the static condenser annulus with a transparent LCD that displays an adaptive annulus, which can be repositioned to counteract meniscus-induced refraction across an entire MTP-24 well. We developed image analysis using Bertrand lens images to determine the misalignment between annulus center and phase ring, enabling the calculation of the required annulus shift. Experiments demonstrate the effectiveness of this image analysis technique. The detected shift was translated into new LCD settings through a linear regression model to ensure proper alignment for the following image. We proved that an algorithm based on background brightness yields a reliable metric for assessing phase contrast conditions within well-plates. The proposed approach substantially increased the phase contrast area in 24-well MTPs at 10× magnification from 5.0% with conventional microscopy to 41.9%, thereby restoring phase contrast conditions throughout the well, except near the edges.</p>","PeriodicalId":18684,"journal":{"name":"Microscopy Research and Technique","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Compensating the Meniscus Effect in Phase Contrast Microscopy Using an LCD for Adaptive Condenser Annulus Shifting.\",\"authors\":\"Florian Nienhaus, Finn Burkhardt, Niels König, Robert H Schmitt\",\"doi\":\"10.1002/jemt.24808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The meniscus effect in cell culture vessels limits the observable areas with phase contrast microscopy. For meniscus effect compensation in microtiter plates (MTPs), we present a method using an LCD to replace the fixed condenser annulus, which enables adaptive annulus shifting based on image analysis. This approach led to an increase in phase contrast area by a factor of 8.3. Utilizing a standard phase contrast microscope, we substituted the static condenser annulus with a transparent LCD that displays an adaptive annulus, which can be repositioned to counteract meniscus-induced refraction across an entire MTP-24 well. We developed image analysis using Bertrand lens images to determine the misalignment between annulus center and phase ring, enabling the calculation of the required annulus shift. Experiments demonstrate the effectiveness of this image analysis technique. The detected shift was translated into new LCD settings through a linear regression model to ensure proper alignment for the following image. We proved that an algorithm based on background brightness yields a reliable metric for assessing phase contrast conditions within well-plates. The proposed approach substantially increased the phase contrast area in 24-well MTPs at 10× magnification from 5.0% with conventional microscopy to 41.9%, thereby restoring phase contrast conditions throughout the well, except near the edges.</p>\",\"PeriodicalId\":18684,\"journal\":{\"name\":\"Microscopy Research and Technique\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy Research and Technique\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/jemt.24808\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANATOMY & MORPHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy Research and Technique","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/jemt.24808","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

细胞培养管的半月板效应限制了相衬显微镜的观察范围。针对微滴法板(MTPs)的半月板效应补偿,我们提出了一种用LCD取代固定聚光环的方法,实现了基于图像分析的自适应环移动。这种方法使相衬面积增加了8.3倍。利用标准相衬显微镜,我们将静态聚光镜环空替换为显示自适应环空的透明LCD,该环空可以重新定位以抵消整个MTP-24井中半月板引起的折射。我们使用Bertrand透镜图像进行图像分析,以确定环空中心和相位环之间的不对准,从而计算所需的环空位移。实验证明了该图像分析技术的有效性。通过线性回归模型将检测到的移位转换为新的LCD设置,以确保以下图像的正确对齐。我们证明了一种基于背景亮度的算法可以为评估井板内的相衬条件提供可靠的度量。该方法在10倍放大率下,将24口MTPs的相衬面积从传统显微镜的5.0%大幅增加到41.9%,从而恢复了除边缘附近以外的整个井的相衬条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Compensating the Meniscus Effect in Phase Contrast Microscopy Using an LCD for Adaptive Condenser Annulus Shifting.

The meniscus effect in cell culture vessels limits the observable areas with phase contrast microscopy. For meniscus effect compensation in microtiter plates (MTPs), we present a method using an LCD to replace the fixed condenser annulus, which enables adaptive annulus shifting based on image analysis. This approach led to an increase in phase contrast area by a factor of 8.3. Utilizing a standard phase contrast microscope, we substituted the static condenser annulus with a transparent LCD that displays an adaptive annulus, which can be repositioned to counteract meniscus-induced refraction across an entire MTP-24 well. We developed image analysis using Bertrand lens images to determine the misalignment between annulus center and phase ring, enabling the calculation of the required annulus shift. Experiments demonstrate the effectiveness of this image analysis technique. The detected shift was translated into new LCD settings through a linear regression model to ensure proper alignment for the following image. We proved that an algorithm based on background brightness yields a reliable metric for assessing phase contrast conditions within well-plates. The proposed approach substantially increased the phase contrast area in 24-well MTPs at 10× magnification from 5.0% with conventional microscopy to 41.9%, thereby restoring phase contrast conditions throughout the well, except near the edges.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microscopy Research and Technique
Microscopy Research and Technique 医学-解剖学与形态学
CiteScore
5.30
自引率
20.00%
发文量
233
审稿时长
4.7 months
期刊介绍: Microscopy Research and Technique (MRT) publishes articles on all aspects of advanced microscopy original architecture and methodologies with applications in the biological, clinical, chemical, and materials sciences. Original basic and applied research as well as technical papers dealing with the various subsets of microscopy are encouraged. MRT is the right form for those developing new microscopy methods or using the microscope to answer key questions in basic and applied research.
期刊最新文献
Leveraging Mask Autoencoder and Crossover Binary Sand Cat Algorithm for Early Detection of Glaucoma. Protective Efficacy of Yogurt, Milk, and Fluoridated Tooth Creme Against Acidic Beverages on Human Teeth: Stereomicroscopic and Ultrastructural Analyses. Laser-Activated Irrigation via Photon-Induced Photoacoustic Streaming and Shock Wave Enhanced Emission on Smear Layer Removal Efficacy, Pushout Bond Strength, and Sealer Adaptation: A SEM Assessment. Phytochemical-Mediated Synthesis and Characterization of Silver Nanoparticles Using Mirabilis jalapa Leaf Extract and Their Antibacterial. Pichia kudriavzevii (JD2) Immobilized on Acid Activated Perlite as a Biosorbent for Solid Phase Extraction of Cr(III) Determination by AAS (Atomic Adsorption Spectroscopy).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1