Di Chen , Wubi Li , Shan Yang , Hang Song , Yu Di , Weixing Zhong , Miao Zhang , Qin Long , Ying Li , Chan Zhao
{"title":"一种新的基于Schirmer条带的泪液基质金属蛋白酶测定方法在干眼症评价中的应用。","authors":"Di Chen , Wubi Li , Shan Yang , Hang Song , Yu Di , Weixing Zhong , Miao Zhang , Qin Long , Ying Li , Chan Zhao","doi":"10.1016/j.jtos.2025.01.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>The diagnosis and evaluation of dry eye require easy-to-use, precise, and consistent tools in clinical setting. Matrix metalloproteinase 9 (MMP-9) has been proven to be a reliable indicator of dry eye inflammation. The aim of this study is to establish an Eu-time resolved fluorescence immunochromatography (Eu-TRFICO) method for quantitative detection of MMP-9 in human tear based upon widely used Schirmer strips.</div></div><div><h3>Methods</h3><div>The Eu-TRFICO method for Schirmer strip-based tear MMP-9 measurements were optimized and assembled. The sensitivity, repeatability and homogeneity were evaluated using MMP-9 standard dilutions. The diagnostic and treatment monitoring performance were evaluated in both dry eye patients and normal subjects.</div></div><div><h3>Results</h3><div>The standard curve equation was y = 0.0037 + 8.0692/[1+ (x/188.322)<sup>−0.8972</sup>] (R2 = 0.99998), and the sensitivity was 0.25 ng/mL. The Schirmer strip-based MMP-9 measurements showed acceptable repeatability and homogeneity with different saturation length in both low and high standard solutions. A total of 162 participants (162 eyes) were enrolled in this study, including 41 normal and 121 dry eye subjects. This method exhibited a sensitivity of 74.17 % and specificity of 77.5 % for dry eye diagnosis, with an AUC value of 0.8275, and cutoff value of 150.67 ng/mL, using normal subjects as negative control. The tear MMP-9 concentrations monitored with this method correlated well with the therapeutic response in dry eye patients.</div></div><div><h3>Conclusions</h3><div>This study developed Eu-TRFICO Schirmer strips with high sensitivity, specificity, precision, and satisfactory clinical testing performance, which provides a convenient and quantitative option for clinical testing of tear MMP-9 in dry eye patients.</div></div>","PeriodicalId":54691,"journal":{"name":"Ocular Surface","volume":"36 ","pages":"Pages 119-125"},"PeriodicalIF":5.9000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel Schirmer strip-based tear matrix metalloproteinase measurement in dry eye evaluation\",\"authors\":\"Di Chen , Wubi Li , Shan Yang , Hang Song , Yu Di , Weixing Zhong , Miao Zhang , Qin Long , Ying Li , Chan Zhao\",\"doi\":\"10.1016/j.jtos.2025.01.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><div>The diagnosis and evaluation of dry eye require easy-to-use, precise, and consistent tools in clinical setting. Matrix metalloproteinase 9 (MMP-9) has been proven to be a reliable indicator of dry eye inflammation. The aim of this study is to establish an Eu-time resolved fluorescence immunochromatography (Eu-TRFICO) method for quantitative detection of MMP-9 in human tear based upon widely used Schirmer strips.</div></div><div><h3>Methods</h3><div>The Eu-TRFICO method for Schirmer strip-based tear MMP-9 measurements were optimized and assembled. The sensitivity, repeatability and homogeneity were evaluated using MMP-9 standard dilutions. The diagnostic and treatment monitoring performance were evaluated in both dry eye patients and normal subjects.</div></div><div><h3>Results</h3><div>The standard curve equation was y = 0.0037 + 8.0692/[1+ (x/188.322)<sup>−0.8972</sup>] (R2 = 0.99998), and the sensitivity was 0.25 ng/mL. The Schirmer strip-based MMP-9 measurements showed acceptable repeatability and homogeneity with different saturation length in both low and high standard solutions. A total of 162 participants (162 eyes) were enrolled in this study, including 41 normal and 121 dry eye subjects. This method exhibited a sensitivity of 74.17 % and specificity of 77.5 % for dry eye diagnosis, with an AUC value of 0.8275, and cutoff value of 150.67 ng/mL, using normal subjects as negative control. The tear MMP-9 concentrations monitored with this method correlated well with the therapeutic response in dry eye patients.</div></div><div><h3>Conclusions</h3><div>This study developed Eu-TRFICO Schirmer strips with high sensitivity, specificity, precision, and satisfactory clinical testing performance, which provides a convenient and quantitative option for clinical testing of tear MMP-9 in dry eye patients.</div></div>\",\"PeriodicalId\":54691,\"journal\":{\"name\":\"Ocular Surface\",\"volume\":\"36 \",\"pages\":\"Pages 119-125\"},\"PeriodicalIF\":5.9000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ocular Surface\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1542012425000126\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ocular Surface","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1542012425000126","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
A novel Schirmer strip-based tear matrix metalloproteinase measurement in dry eye evaluation
Purpose
The diagnosis and evaluation of dry eye require easy-to-use, precise, and consistent tools in clinical setting. Matrix metalloproteinase 9 (MMP-9) has been proven to be a reliable indicator of dry eye inflammation. The aim of this study is to establish an Eu-time resolved fluorescence immunochromatography (Eu-TRFICO) method for quantitative detection of MMP-9 in human tear based upon widely used Schirmer strips.
Methods
The Eu-TRFICO method for Schirmer strip-based tear MMP-9 measurements were optimized and assembled. The sensitivity, repeatability and homogeneity were evaluated using MMP-9 standard dilutions. The diagnostic and treatment monitoring performance were evaluated in both dry eye patients and normal subjects.
Results
The standard curve equation was y = 0.0037 + 8.0692/[1+ (x/188.322)−0.8972] (R2 = 0.99998), and the sensitivity was 0.25 ng/mL. The Schirmer strip-based MMP-9 measurements showed acceptable repeatability and homogeneity with different saturation length in both low and high standard solutions. A total of 162 participants (162 eyes) were enrolled in this study, including 41 normal and 121 dry eye subjects. This method exhibited a sensitivity of 74.17 % and specificity of 77.5 % for dry eye diagnosis, with an AUC value of 0.8275, and cutoff value of 150.67 ng/mL, using normal subjects as negative control. The tear MMP-9 concentrations monitored with this method correlated well with the therapeutic response in dry eye patients.
Conclusions
This study developed Eu-TRFICO Schirmer strips with high sensitivity, specificity, precision, and satisfactory clinical testing performance, which provides a convenient and quantitative option for clinical testing of tear MMP-9 in dry eye patients.
期刊介绍:
The Ocular Surface, a quarterly, a peer-reviewed journal, is an authoritative resource that integrates and interprets major findings in diverse fields related to the ocular surface, including ophthalmology, optometry, genetics, molecular biology, pharmacology, immunology, infectious disease, and epidemiology. Its critical review articles cover the most current knowledge on medical and surgical management of ocular surface pathology, new understandings of ocular surface physiology, the meaning of recent discoveries on how the ocular surface responds to injury and disease, and updates on drug and device development. The journal also publishes select original research reports and articles describing cutting-edge techniques and technology in the field.
Benefits to authors
We also provide many author benefits, such as free PDFs, a liberal copyright policy, special discounts on Elsevier publications and much more. Please click here for more information on our author services.
Please see our Guide for Authors for information on article submission. If you require any further information or help, please visit our Support Center