羧化石墨烯:一种增强IgA-SARS-CoV-2电化学生物传感的创新方法。

IF 5.6 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL Biosensors-Basel Pub Date : 2025-01-09 DOI:10.3390/bios15010034
Luciana de Souza Freire, Ariamna María Dip Gandarilla, Yonny Romaguera Barcelay, Camila Macena Ruzo, Barbara Batista Salgado, Ana P M Tavares, Francisco Xavier Nobre, Julio Nino de Souza Neto, Spartaco Astolfi-Filho, Ștefan Țălu, Pritesh Lalwani, Niranjan Patra, Walter Ricardo Brito
{"title":"羧化石墨烯:一种增强IgA-SARS-CoV-2电化学生物传感的创新方法。","authors":"Luciana de Souza Freire, Ariamna María Dip Gandarilla, Yonny Romaguera Barcelay, Camila Macena Ruzo, Barbara Batista Salgado, Ana P M Tavares, Francisco Xavier Nobre, Julio Nino de Souza Neto, Spartaco Astolfi-Filho, Ștefan Țălu, Pritesh Lalwani, Niranjan Patra, Walter Ricardo Brito","doi":"10.3390/bios15010034","DOIUrl":null,"url":null,"abstract":"<p><p>Biosensors harness biological materials as receptors linked to transducers, enabling the capture and transformation of primary biorecognition signals into measurable outputs. This study presents a novel carboxylation method for synthesizing carboxylated graphene (CG) under acidic conditions, enhancing biosensing capabilities. The characterization of the CG was performed using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Raman spectroscopy, thermogravimetric analysis (TGA), and X-ray diffraction (XRD). We modified screen-printed carbon electrodes (SPCEs) with CG to immobilize the SARS-CoV-2 N-protein, facilitating targeted detection of IgA antibodies (IgA-SARS-CoV-2). The analytical performance was assessed via electrochemical techniques such as cyclic voltammetry and electrochemical impedance spectroscopy, confirming CG synthesis effectiveness and biosensor functionality. The developed biosensor efficiently detects IgA-SARS-CoV-2 across a dilution range of 1:1000 to 1:200 <i>v</i>/<i>v</i> in a phosphate-buffered saline (PBS) solution, with a limit of detection calculated at 1:1601 <i>v</i>/<i>v</i>. This device shows considerable potential because of its fast response time, miniaturized design facilitated by SPCEs, reduced sample volume requirements, high sensitivity and specificity, low detection limits, and signal enhancement achieved through nanomaterial integration.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"15 1","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11764328/pdf/","citationCount":"0","resultStr":"{\"title\":\"Carboxylated Graphene: An Innovative Approach to Enhanced IgA-SARS-CoV-2 Electrochemical Biosensing.\",\"authors\":\"Luciana de Souza Freire, Ariamna María Dip Gandarilla, Yonny Romaguera Barcelay, Camila Macena Ruzo, Barbara Batista Salgado, Ana P M Tavares, Francisco Xavier Nobre, Julio Nino de Souza Neto, Spartaco Astolfi-Filho, Ștefan Țălu, Pritesh Lalwani, Niranjan Patra, Walter Ricardo Brito\",\"doi\":\"10.3390/bios15010034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Biosensors harness biological materials as receptors linked to transducers, enabling the capture and transformation of primary biorecognition signals into measurable outputs. This study presents a novel carboxylation method for synthesizing carboxylated graphene (CG) under acidic conditions, enhancing biosensing capabilities. The characterization of the CG was performed using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Raman spectroscopy, thermogravimetric analysis (TGA), and X-ray diffraction (XRD). We modified screen-printed carbon electrodes (SPCEs) with CG to immobilize the SARS-CoV-2 N-protein, facilitating targeted detection of IgA antibodies (IgA-SARS-CoV-2). The analytical performance was assessed via electrochemical techniques such as cyclic voltammetry and electrochemical impedance spectroscopy, confirming CG synthesis effectiveness and biosensor functionality. The developed biosensor efficiently detects IgA-SARS-CoV-2 across a dilution range of 1:1000 to 1:200 <i>v</i>/<i>v</i> in a phosphate-buffered saline (PBS) solution, with a limit of detection calculated at 1:1601 <i>v</i>/<i>v</i>. This device shows considerable potential because of its fast response time, miniaturized design facilitated by SPCEs, reduced sample volume requirements, high sensitivity and specificity, low detection limits, and signal enhancement achieved through nanomaterial integration.</p>\",\"PeriodicalId\":48608,\"journal\":{\"name\":\"Biosensors-Basel\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-01-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11764328/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors-Basel\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bios15010034\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios15010034","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

生物传感器利用生物材料作为与换能器相连的受体,能够捕获初级生物识别信号并将其转化为可测量的输出。本研究提出了一种在酸性条件下合成羧基化石墨烯(CG)的新方法,增强了生物传感能力。利用扫描电子显微镜(SEM)、能量色散x射线能谱(EDS)、拉曼光谱(Raman spectroscopy)、热重分析(TGA)和x射线衍射(XRD)对CG进行了表征。我们用CG修饰了丝网印刷碳电极(SPCEs)来固定SARS-CoV-2 n蛋白,从而促进了IgA抗体(IgA-SARS-CoV-2)的靶向检测。通过循环伏安法和电化学阻抗谱等电化学技术评估了分析性能,确认了CG合成的有效性和生物传感器的功能。开发的生物传感器在磷酸盐缓冲盐水(PBS)溶液中,在1:1000至1:20 00 v/v的稀释范围内有效检测IgA-SARS-CoV-2,检测限为1:1601 v/v。该装置具有快速响应时间、spce促进的小型化设计、减少样品体积要求、高灵敏度和特异性、低检测限以及通过纳米材料集成实现的信号增强等优点,具有相当大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Carboxylated Graphene: An Innovative Approach to Enhanced IgA-SARS-CoV-2 Electrochemical Biosensing.

Biosensors harness biological materials as receptors linked to transducers, enabling the capture and transformation of primary biorecognition signals into measurable outputs. This study presents a novel carboxylation method for synthesizing carboxylated graphene (CG) under acidic conditions, enhancing biosensing capabilities. The characterization of the CG was performed using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Raman spectroscopy, thermogravimetric analysis (TGA), and X-ray diffraction (XRD). We modified screen-printed carbon electrodes (SPCEs) with CG to immobilize the SARS-CoV-2 N-protein, facilitating targeted detection of IgA antibodies (IgA-SARS-CoV-2). The analytical performance was assessed via electrochemical techniques such as cyclic voltammetry and electrochemical impedance spectroscopy, confirming CG synthesis effectiveness and biosensor functionality. The developed biosensor efficiently detects IgA-SARS-CoV-2 across a dilution range of 1:1000 to 1:200 v/v in a phosphate-buffered saline (PBS) solution, with a limit of detection calculated at 1:1601 v/v. This device shows considerable potential because of its fast response time, miniaturized design facilitated by SPCEs, reduced sample volume requirements, high sensitivity and specificity, low detection limits, and signal enhancement achieved through nanomaterial integration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
期刊最新文献
A Multimodal Time Point Labeling Approach for Analyzing Mastication and Swallowing Dynamics. Smart Bandage Based on Batteryless NFC for Wireless Pressure and Wound State Monitoring. Catalytic Reduction of H2O2 by Polyvinylpyrrolidone Nickel Oxide Nanozymatic Activity and Colorimetric Sensing of Ascorbic Acid. Rapid Eukaryotic Impedimetric Biosensing of Naproxen and Isoniazid: A Proof-of-Concept for Acute Toxicity Monitoring. An LSPR-Active AuNP-Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1