糖尿病和非糖尿病患者超声乳化术后瞳孔动态变化。

IF 1.5 4区 医学 Q3 OPHTHALMOLOGY Clinical and Experimental Optometry Pub Date : 2025-11-01 Epub Date: 2025-01-26 DOI:10.1080/08164622.2025.2452269
Levent Doğan, İbrahim Edhem Yılmaz, Mustafa Berhuni, Gizem Gürbostan Soysal, Zeynep Özer Özcan
{"title":"糖尿病和非糖尿病患者超声乳化术后瞳孔动态变化。","authors":"Levent Doğan, İbrahim Edhem Yılmaz, Mustafa Berhuni, Gizem Gürbostan Soysal, Zeynep Özer Özcan","doi":"10.1080/08164622.2025.2452269","DOIUrl":null,"url":null,"abstract":"<p><strong>Clinical relevance: </strong>Although laser refractive surgeries and multifocal intraocular lens implantation are generally avoided in patients with diabetic retinopathy, a substantial proportion of well-glycaemic-controlled type 2 diabetes mellitus patients are considered for these procedures. Pupil dynamics play a significant role in determining postoperative satisfaction in these patients.</p><p><strong>Background: </strong>To evaluate pupillary dynamics in patients with and without diabetes following uneventful phacoemulsification surgery.</p><p><strong>Method: </strong>This retrospective study involved 86 patients with type-2 diabetes and 41 non-diabetic patients undergoing phacoemulsification. Pupillary measurements were performed using the Sirius Topographer (CSO, Firenze, Italy) preoperatively and at the 1-month and 3-month postoperatively. Diabetic patients were categorised into non-diabetic retinopathy (without diabetic retinopathy), non-proliferative diabetic retinopathy (NPDR), and proliferative diabetic retinopathy (PDR) subgroups based on the presence and severity of diabetic retinopathy. Baseline and postoperative pupillometric values were then evaluated for all groups.</p><p><strong>Results: </strong>Preoperatively, baseline scotopic, mesopic, and photopic pupil diameters, and pupil redilation velocity were smaller in the NPDR and PDR subgroups compared to the control group (<i>p</i> < 0.05, for all). At 1-month postoperatively, pupil diameters in all lighting conditions significantly decreased in both the control and non-diabetic retinopathy groups (<i>p</i> < 0.05, for all), while pupil dilation rate increased (<i>p</i> = 0.011 and <i>p</i> = 0.002, respectively). In the PDR group, a significant increase in photopic pupil diameter was observed at 1 and 3 months postoperatively (<i>p</i> = 0.018 and <i>p</i> = 0.030, respectively). The PDR and NPDR groups showed a significant decrease in postoperative first- and third-month scotopic pupil diameter (<i>p</i> < 0.05, for all).</p><p><strong>Conclusion: </strong>Pupil diameter was smaller in diabetic patients compared to controls pre-and postoperatively. Patients with non- diabetic retinopathy and NPDR, who already exhibited smaller pupil diameters in all lighting conditions than the controls (in mesopic condition, 3.54 cf. 3.66, and 3.11 cf. 3.66 mm, respectively), experienced a further reduction in pupil size following phacoemulsification.</p>","PeriodicalId":10214,"journal":{"name":"Clinical and Experimental Optometry","volume":" ","pages":"998-1004"},"PeriodicalIF":1.5000,"publicationDate":"2025-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pupillary dynamics in diabetic and nondiabetic patients following uneventful phacoemulsification.\",\"authors\":\"Levent Doğan, İbrahim Edhem Yılmaz, Mustafa Berhuni, Gizem Gürbostan Soysal, Zeynep Özer Özcan\",\"doi\":\"10.1080/08164622.2025.2452269\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Clinical relevance: </strong>Although laser refractive surgeries and multifocal intraocular lens implantation are generally avoided in patients with diabetic retinopathy, a substantial proportion of well-glycaemic-controlled type 2 diabetes mellitus patients are considered for these procedures. Pupil dynamics play a significant role in determining postoperative satisfaction in these patients.</p><p><strong>Background: </strong>To evaluate pupillary dynamics in patients with and without diabetes following uneventful phacoemulsification surgery.</p><p><strong>Method: </strong>This retrospective study involved 86 patients with type-2 diabetes and 41 non-diabetic patients undergoing phacoemulsification. Pupillary measurements were performed using the Sirius Topographer (CSO, Firenze, Italy) preoperatively and at the 1-month and 3-month postoperatively. Diabetic patients were categorised into non-diabetic retinopathy (without diabetic retinopathy), non-proliferative diabetic retinopathy (NPDR), and proliferative diabetic retinopathy (PDR) subgroups based on the presence and severity of diabetic retinopathy. Baseline and postoperative pupillometric values were then evaluated for all groups.</p><p><strong>Results: </strong>Preoperatively, baseline scotopic, mesopic, and photopic pupil diameters, and pupil redilation velocity were smaller in the NPDR and PDR subgroups compared to the control group (<i>p</i> < 0.05, for all). At 1-month postoperatively, pupil diameters in all lighting conditions significantly decreased in both the control and non-diabetic retinopathy groups (<i>p</i> < 0.05, for all), while pupil dilation rate increased (<i>p</i> = 0.011 and <i>p</i> = 0.002, respectively). In the PDR group, a significant increase in photopic pupil diameter was observed at 1 and 3 months postoperatively (<i>p</i> = 0.018 and <i>p</i> = 0.030, respectively). The PDR and NPDR groups showed a significant decrease in postoperative first- and third-month scotopic pupil diameter (<i>p</i> < 0.05, for all).</p><p><strong>Conclusion: </strong>Pupil diameter was smaller in diabetic patients compared to controls pre-and postoperatively. Patients with non- diabetic retinopathy and NPDR, who already exhibited smaller pupil diameters in all lighting conditions than the controls (in mesopic condition, 3.54 cf. 3.66, and 3.11 cf. 3.66 mm, respectively), experienced a further reduction in pupil size following phacoemulsification.</p>\",\"PeriodicalId\":10214,\"journal\":{\"name\":\"Clinical and Experimental Optometry\",\"volume\":\" \",\"pages\":\"998-1004\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Experimental Optometry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08164622.2025.2452269\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Optometry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08164622.2025.2452269","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

临床意义:虽然糖尿病视网膜病变患者通常避免激光屈光手术和多焦点人工晶状体植入术,但相当一部分血糖控制良好的2型糖尿病患者被考虑进行这些手术。在这些患者中,瞳孔动态在决定术后满意度方面起着重要作用。背景:评估有无糖尿病患者超声乳化术后瞳孔动态。方法:回顾性研究86例2型糖尿病患者和41例非糖尿病患者行超声乳化术。术前、术后1个月和3个月分别使用Sirius Topographer (CSO, florence, Italy)进行瞳孔测量。根据糖尿病视网膜病变的存在和严重程度,将糖尿病患者分为非糖尿病视网膜病变(无糖尿病视网膜病变)、非增殖性糖尿病视网膜病变(NPDR)和增殖性糖尿病视网膜病变(PDR)亚组。然后对所有组的基线和术后瞳孔测量值进行评估。结果:术前,NPDR和PDR亚组的基线暗位、中位、光位瞳孔直径和瞳孔再扩张速度均小于对照组(p = 0.011和p = 0.002)。PDR组术后1个月和3个月光瞳直径明显增加(p = 0.018和p = 0.030)。PDR组和NPDR组术后第1个月和第3个月暗瞳直径显著降低(p)。结论:糖尿病患者的瞳孔直径比对照组术前和术后更小。非糖尿病性视网膜病变和NPDR患者在所有光照条件下的瞳孔直径都比对照组小(中视条件下分别为3.54 cf. 3.66 mm和3.11 cf. 3.66 mm),超声乳化术后瞳孔尺寸进一步缩小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Pupillary dynamics in diabetic and nondiabetic patients following uneventful phacoemulsification.

Clinical relevance: Although laser refractive surgeries and multifocal intraocular lens implantation are generally avoided in patients with diabetic retinopathy, a substantial proportion of well-glycaemic-controlled type 2 diabetes mellitus patients are considered for these procedures. Pupil dynamics play a significant role in determining postoperative satisfaction in these patients.

Background: To evaluate pupillary dynamics in patients with and without diabetes following uneventful phacoemulsification surgery.

Method: This retrospective study involved 86 patients with type-2 diabetes and 41 non-diabetic patients undergoing phacoemulsification. Pupillary measurements were performed using the Sirius Topographer (CSO, Firenze, Italy) preoperatively and at the 1-month and 3-month postoperatively. Diabetic patients were categorised into non-diabetic retinopathy (without diabetic retinopathy), non-proliferative diabetic retinopathy (NPDR), and proliferative diabetic retinopathy (PDR) subgroups based on the presence and severity of diabetic retinopathy. Baseline and postoperative pupillometric values were then evaluated for all groups.

Results: Preoperatively, baseline scotopic, mesopic, and photopic pupil diameters, and pupil redilation velocity were smaller in the NPDR and PDR subgroups compared to the control group (p < 0.05, for all). At 1-month postoperatively, pupil diameters in all lighting conditions significantly decreased in both the control and non-diabetic retinopathy groups (p < 0.05, for all), while pupil dilation rate increased (p = 0.011 and p = 0.002, respectively). In the PDR group, a significant increase in photopic pupil diameter was observed at 1 and 3 months postoperatively (p = 0.018 and p = 0.030, respectively). The PDR and NPDR groups showed a significant decrease in postoperative first- and third-month scotopic pupil diameter (p < 0.05, for all).

Conclusion: Pupil diameter was smaller in diabetic patients compared to controls pre-and postoperatively. Patients with non- diabetic retinopathy and NPDR, who already exhibited smaller pupil diameters in all lighting conditions than the controls (in mesopic condition, 3.54 cf. 3.66, and 3.11 cf. 3.66 mm, respectively), experienced a further reduction in pupil size following phacoemulsification.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
5.30%
发文量
132
审稿时长
6-12 weeks
期刊介绍: Clinical and Experimental Optometry is a peer reviewed journal listed by ISI and abstracted by PubMed, Web of Science, Scopus, Science Citation Index and Current Contents. It publishes original research papers and reviews in clinical optometry and vision science. Debate and discussion of controversial scientific and clinical issues is encouraged and letters to the Editor and short communications expressing points of view on matters within the Journal''s areas of interest are welcome. The Journal is published six times annually.
期刊最新文献
Effectiveness of spectacle lenses with highly aspherical lenslets in slowing axial elongation among non-myopic children. Coloured filters and lenses for reading discomfort and difficulty: an Australian and New Zealand perspective. Impact of myopia management university-based learning on self-reported clinical practice. Modelling systematic evaluation of technology enhanced learning in optometric education in Australia and New Zealand. Prevalence and risk factors of premyopia in preschoolers: a kindergarten-based cluster sampling study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1