用光泵磁强计绘制受刺激的指外展肌的磁场图。

IF 2 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Biomedical Physics & Engineering Express Pub Date : 2025-02-06 DOI:10.1088/2057-1976/adaec5
Marlen Kruse, Simon Nordenström, Stefan Hartwig, Justus Marquetand, Victor Lebedev, Thomas Middelmann, Philip J Broser
{"title":"用光泵磁强计绘制受刺激的指外展肌的磁场图。","authors":"Marlen Kruse, Simon Nordenström, Stefan Hartwig, Justus Marquetand, Victor Lebedev, Thomas Middelmann, Philip J Broser","doi":"10.1088/2057-1976/adaec5","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG).<i>Approach.</i>Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact. Then, the electromagnetic muscle activity was electrically evoked utilizing stepwise increasing currents at the cubital tunnel at the ulnar nerve. Evoked myomagnetic activity was recorded with 18 channels, three per sensor. As the measurements were performed in PTB's magnetically shielded room (BMSR-2) no averaging and only moderate filtering was applied.<i>Main results.</i>The myomagnetic vector field could be successfully mapped. The obtained spatial structure with a radial symmetry corresponds to the expectations from the ADM's parallel muscle architecture. The temporal evolution exhibits an up to four-phasic shape. Implications for future experiments are derived and needs for sensor performance improvements are identified<i>. Significance.</i>The use of an OPM array with small (∼3 mm edge length) sensing voxels enabled the mapping of the magnetic vector field of the ADM. This allowed visualization of the spatiotemporal evolution of the muscle's evoked magnetic field and gives implications for future experiments. In the future, high density OPM grids may enable high-accuracy determination of muscle parameters such as innervation zone position, pennation angle, and propagation velocities.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetic vector field mapping of the stimulated abductor digiti minimi muscle with optically pumped magnetometers.\",\"authors\":\"Marlen Kruse, Simon Nordenström, Stefan Hartwig, Justus Marquetand, Victor Lebedev, Thomas Middelmann, Philip J Broser\",\"doi\":\"10.1088/2057-1976/adaec5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective.</i>Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG).<i>Approach.</i>Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact. Then, the electromagnetic muscle activity was electrically evoked utilizing stepwise increasing currents at the cubital tunnel at the ulnar nerve. Evoked myomagnetic activity was recorded with 18 channels, three per sensor. As the measurements were performed in PTB's magnetically shielded room (BMSR-2) no averaging and only moderate filtering was applied.<i>Main results.</i>The myomagnetic vector field could be successfully mapped. The obtained spatial structure with a radial symmetry corresponds to the expectations from the ADM's parallel muscle architecture. The temporal evolution exhibits an up to four-phasic shape. Implications for future experiments are derived and needs for sensor performance improvements are identified<i>. Significance.</i>The use of an OPM array with small (∼3 mm edge length) sensing voxels enabled the mapping of the magnetic vector field of the ADM. This allowed visualization of the spatiotemporal evolution of the muscle's evoked magnetic field and gives implications for future experiments. In the future, high density OPM grids may enable high-accuracy determination of muscle parameters such as innervation zone position, pennation angle, and propagation velocities.</p>\",\"PeriodicalId\":8896,\"journal\":{\"name\":\"Biomedical Physics & Engineering Express\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-02-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Physics & Engineering Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2057-1976/adaec5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/adaec5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用三轴光泵磁强计(OPMs)绘制电刺激后直肌的肌磁场,以评估磁强图(MMG)的潜在益处。入路:将6个三轴opm按两排排列,每个opm沿外展小指肌(ADM)放置3个传感器。上排传感器相对于下排倾斜45°,所有传感器与皮肤表面紧密对齐,不直接接触。然后,利用尺神经肘管处逐步增加的电流电诱发电磁肌肉活动。诱发的肌磁活动用18个通道记录,每个传感器三个通道。由于测量是在PTB的磁屏蔽室(BMSR-2)中进行的,所以没有进行平均,只进行了适度的滤波。主要结果:肌磁场可以成功地映射。获得的空间结构具有径向对称,符合ADM平行肌肉结构的期望。时间演化呈现出多达四相的形状。意义:使用具有小(~ 3mm边缘长度)传感体素的OPM阵列,可以映射adm的磁场矢量。这使得肌肉诱发磁场的时空演变可视化,并为未来的实验提供了启示。在未来,高密度OPM网格可以高精度地确定肌肉参数,如神经支配区位置、笔触角度和传播速度。& # xD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Magnetic vector field mapping of the stimulated abductor digiti minimi muscle with optically pumped magnetometers.

Objective.Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG).Approach.Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact. Then, the electromagnetic muscle activity was electrically evoked utilizing stepwise increasing currents at the cubital tunnel at the ulnar nerve. Evoked myomagnetic activity was recorded with 18 channels, three per sensor. As the measurements were performed in PTB's magnetically shielded room (BMSR-2) no averaging and only moderate filtering was applied.Main results.The myomagnetic vector field could be successfully mapped. The obtained spatial structure with a radial symmetry corresponds to the expectations from the ADM's parallel muscle architecture. The temporal evolution exhibits an up to four-phasic shape. Implications for future experiments are derived and needs for sensor performance improvements are identified. Significance.The use of an OPM array with small (∼3 mm edge length) sensing voxels enabled the mapping of the magnetic vector field of the ADM. This allowed visualization of the spatiotemporal evolution of the muscle's evoked magnetic field and gives implications for future experiments. In the future, high density OPM grids may enable high-accuracy determination of muscle parameters such as innervation zone position, pennation angle, and propagation velocities.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
期刊最新文献
Parametric regression model approach for CT-based prediction of stopping power ratio for a Hounsfield look-up table. Challenges and Strategies in Fusion of Probes and Imaging Equipment for Neural Imaging. Numerical and Experimental Assessment of Implant-Induced Thermal Risks During Electrosurgical Procedures. Prediction of an fMRI-based schizophrenia biomarker from EEG using dynamic functional connectivity: a simultaneous EEG-fMRI study. MATGAN: a generative adversarial network with multi-scale attention and Huber loss for brain MRI registration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1