一种用于pt级痕量气体检测的腔增强mems光声传感器

IF 3.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL Sensors and Actuators B: Chemical Pub Date : 2025-05-01 Epub Date: 2025-01-28 DOI:10.1016/j.snb.2025.137313
Jacopo Pelini , Stefano Dello Russo , Zhen Wang , Iacopo Galli , Pablo Cancio Pastor , Inaki Lopez Garcia , Maria Concetta Canino , Alberto Roncaglia , Naota Akikusa , Wei Ren , Paolo De Natale , Mario Siciliani de Cumis , Simone Borri
{"title":"一种用于pt级痕量气体检测的腔增强mems光声传感器","authors":"Jacopo Pelini ,&nbsp;Stefano Dello Russo ,&nbsp;Zhen Wang ,&nbsp;Iacopo Galli ,&nbsp;Pablo Cancio Pastor ,&nbsp;Inaki Lopez Garcia ,&nbsp;Maria Concetta Canino ,&nbsp;Alberto Roncaglia ,&nbsp;Naota Akikusa ,&nbsp;Wei Ren ,&nbsp;Paolo De Natale ,&nbsp;Mario Siciliani de Cumis ,&nbsp;Simone Borri","doi":"10.1016/j.snb.2025.137313","DOIUrl":null,"url":null,"abstract":"<div><div>Part-per-trillion level trace-molecule detection is becoming increasingly crucial for a variety of fields in our modern society, from climate change monitoring and mitigation to health studies, from industrial processes control to safety and security. The race towards more performing sensors is witnessing a rapid evolution of photoacoustic systems, whose high degree of flexibility allows them to merge their robustness and compactness to cavity-enhanced configurations, boosting their ultimate sensitivity. This work proposes an advanced configuration of a cavity-enhanced cantilever-based photo-acoustic sensor. The developed setup exploits the advantages of mid-IR detection and introduces significant novelties in the key components, namely a non-conventional silicon “racket-shaped” cantilever, a combination of a dual-tube acoustic resonator and optical cavity to enhance the photoacoustic signal, and an improved optical readout system consisting in a stabilized balanced Michelson interferometer. With a final detection sensitivity of dry N<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span>O down to 17 parts-per-trillion for 20 s of integration time, corresponding to a Normalized Noise Equivalent Absorption coefficient equal to 5.98 <span><math><mrow><mo>×</mo><mspace></mspace><mn>10</mn></mrow></math></span><sup>-11</sup>cm <sup>-1</sup> WHz<sup>-1/2</sup>, the achieved performance is in line with the best results obtained with PAS-based sensing addressing the same target molecule. This demonstrates the wide range of yet unexplored configurations of photoacoustic systems that can be exploited towards real-time sub-ppt sensors for practical detection of trace chemicals in the air.</div></div>","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"430 ","pages":"Article 137313"},"PeriodicalIF":3.7000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A cavity-enhanced MEMS-based photoacoustic sensor for ppt-level trace-gas detection\",\"authors\":\"Jacopo Pelini ,&nbsp;Stefano Dello Russo ,&nbsp;Zhen Wang ,&nbsp;Iacopo Galli ,&nbsp;Pablo Cancio Pastor ,&nbsp;Inaki Lopez Garcia ,&nbsp;Maria Concetta Canino ,&nbsp;Alberto Roncaglia ,&nbsp;Naota Akikusa ,&nbsp;Wei Ren ,&nbsp;Paolo De Natale ,&nbsp;Mario Siciliani de Cumis ,&nbsp;Simone Borri\",\"doi\":\"10.1016/j.snb.2025.137313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Part-per-trillion level trace-molecule detection is becoming increasingly crucial for a variety of fields in our modern society, from climate change monitoring and mitigation to health studies, from industrial processes control to safety and security. The race towards more performing sensors is witnessing a rapid evolution of photoacoustic systems, whose high degree of flexibility allows them to merge their robustness and compactness to cavity-enhanced configurations, boosting their ultimate sensitivity. This work proposes an advanced configuration of a cavity-enhanced cantilever-based photo-acoustic sensor. The developed setup exploits the advantages of mid-IR detection and introduces significant novelties in the key components, namely a non-conventional silicon “racket-shaped” cantilever, a combination of a dual-tube acoustic resonator and optical cavity to enhance the photoacoustic signal, and an improved optical readout system consisting in a stabilized balanced Michelson interferometer. With a final detection sensitivity of dry N<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span>O down to 17 parts-per-trillion for 20 s of integration time, corresponding to a Normalized Noise Equivalent Absorption coefficient equal to 5.98 <span><math><mrow><mo>×</mo><mspace></mspace><mn>10</mn></mrow></math></span><sup>-11</sup>cm <sup>-1</sup> WHz<sup>-1/2</sup>, the achieved performance is in line with the best results obtained with PAS-based sensing addressing the same target molecule. This demonstrates the wide range of yet unexplored configurations of photoacoustic systems that can be exploited towards real-time sub-ppt sensors for practical detection of trace chemicals in the air.</div></div>\",\"PeriodicalId\":425,\"journal\":{\"name\":\"Sensors and Actuators B: Chemical\",\"volume\":\"430 \",\"pages\":\"Article 137313\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators B: Chemical\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0925400525000887\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0925400525000887","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

从气候变化监测和减缓到健康研究,从工业过程控制到安全保障,在现代社会的各个领域,万亿分之一级别的痕量分子检测正变得越来越重要。对性能更高的传感器的竞争见证了光声系统的快速发展,其高度的灵活性使它们能够将其稳健性和紧凑性与腔增强配置相结合,从而提高其最终灵敏度。这项工作提出了一种腔增强悬臂式光声传感器的先进配置。开发的装置利用了中红外探测的优势,并在关键部件上引入了显著的创新,即非传统的硅“球拍形”悬臂,双管声学谐振器和光学腔的组合以增强光声信号,以及由稳定平衡迈克尔逊干涉仪组成的改进的光学读出系统。在20秒的积分时间内,干燥N22O的最终检测灵敏度降至17万亿分之一,对应于归一化噪声等效吸收系数等于5.98 ×10×10-11cm -1 WHz-1/2,所获得的性能与基于pass的传感处理相同目标分子的最佳结果一致。这展示了广泛的尚未开发的光声系统配置,可以用于实时亚ppt传感器,用于实际检测空气中的痕量化学物质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A cavity-enhanced MEMS-based photoacoustic sensor for ppt-level trace-gas detection
Part-per-trillion level trace-molecule detection is becoming increasingly crucial for a variety of fields in our modern society, from climate change monitoring and mitigation to health studies, from industrial processes control to safety and security. The race towards more performing sensors is witnessing a rapid evolution of photoacoustic systems, whose high degree of flexibility allows them to merge their robustness and compactness to cavity-enhanced configurations, boosting their ultimate sensitivity. This work proposes an advanced configuration of a cavity-enhanced cantilever-based photo-acoustic sensor. The developed setup exploits the advantages of mid-IR detection and introduces significant novelties in the key components, namely a non-conventional silicon “racket-shaped” cantilever, a combination of a dual-tube acoustic resonator and optical cavity to enhance the photoacoustic signal, and an improved optical readout system consisting in a stabilized balanced Michelson interferometer. With a final detection sensitivity of dry N2O down to 17 parts-per-trillion for 20 s of integration time, corresponding to a Normalized Noise Equivalent Absorption coefficient equal to 5.98 ×10-11cm -1 WHz-1/2, the achieved performance is in line with the best results obtained with PAS-based sensing addressing the same target molecule. This demonstrates the wide range of yet unexplored configurations of photoacoustic systems that can be exploited towards real-time sub-ppt sensors for practical detection of trace chemicals in the air.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
期刊最新文献
Sensitive and miniaturized methane sensor operated at heating-mode of DFB laser Spherical nucleic acid-confined split DNAzyme enables rapid and sensitive electrochemiluminescence detection of myocardial microRNA Harnessing smart biointerfaces: From precision tumor cell capture to clinical applications Colorimetric sensor array based on one-dimensional PtFe nanowires with peroxidase-like activities for recognition of unsaturated fatty acids in edible oils Flexible organic transistor sensors with quercetin-embedded micro-channels for pico-level detection of reactive oxygen species
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1