MCL-PRO-CAT 的开发和初步验证:计算机化自适应测试,旨在从患者的角度测量多焦点隐形眼镜的性能。

IF 4.1 3区 医学 Q1 OPHTHALMOLOGY Contact Lens & Anterior Eye Pub Date : 2025-01-31 DOI:10.1016/j.clae.2025.102378
Elsa Albero-Ros, Amalia Lorente-Velázquez, David Madrid-Costa, Mariano González-Pérez
{"title":"MCL-PRO-CAT 的开发和初步验证:计算机化自适应测试,旨在从患者的角度测量多焦点隐形眼镜的性能。","authors":"Elsa Albero-Ros, Amalia Lorente-Velázquez, David Madrid-Costa, Mariano González-Pérez","doi":"10.1016/j.clae.2025.102378","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To create a valid and reliable computer-adaptive testing (CAT) tool for assessing Multifocal Contact Lens (MCL) performance in presbyopic individuals, ensuring high precision. The self-administered tool will initially be accessible online in Spanish.</p><p><strong>Methods: </strong>Five steps were followed for the correct development of the instruments: item bank development, item refinement phase, item response theory calibration of the refined item bank, CAT simulations and design, and an initial validation study. A total of 1163 presbyopic patients were involved in the over-all study. Convergent validity was assessed by comparing results to the CLDQ-8 questionnaire, and repeatability assessment was performed two weeks after the initial completion.</p><p><strong>Results: </strong>The final item bank consisted of 108 items assessing various relevant domains for MCL performance evaluation. The calibration study showed a person separation index of 4.69 and a reliability of 0.96 along with a measurement precision of 0.27. The final CAT distinguished between 16 levels of MCL performance by presenting an average of 10.61  ± 1.00 items per patient, with an average completion time of 3:04 ± 1:24 min. Signs of convergent validity showed a correlation of 0.73 and repeatability was assessed showing an intraclass Correlation Coefficient of 0.881 with a 95% Confidence Interval 0,815-0,924, and Limits of Agreement of  ± 1.07.</p><p><strong>Conclusion: </strong>The MCL-PRO-CAT is a groundbreaking tool for evaluating MCL performance in presbyopic individuals. With automated scoring and fewer items, it was feasible, valid, and precise, enhancing clinical practicality.</p>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":" ","pages":"102378"},"PeriodicalIF":4.1000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Initial Validation of the MCL-PRO-CAT: A computerized adaptive test designed to measure multifocal contact lens performance from the patient's perspective.\",\"authors\":\"Elsa Albero-Ros, Amalia Lorente-Velázquez, David Madrid-Costa, Mariano González-Pérez\",\"doi\":\"10.1016/j.clae.2025.102378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To create a valid and reliable computer-adaptive testing (CAT) tool for assessing Multifocal Contact Lens (MCL) performance in presbyopic individuals, ensuring high precision. The self-administered tool will initially be accessible online in Spanish.</p><p><strong>Methods: </strong>Five steps were followed for the correct development of the instruments: item bank development, item refinement phase, item response theory calibration of the refined item bank, CAT simulations and design, and an initial validation study. A total of 1163 presbyopic patients were involved in the over-all study. Convergent validity was assessed by comparing results to the CLDQ-8 questionnaire, and repeatability assessment was performed two weeks after the initial completion.</p><p><strong>Results: </strong>The final item bank consisted of 108 items assessing various relevant domains for MCL performance evaluation. The calibration study showed a person separation index of 4.69 and a reliability of 0.96 along with a measurement precision of 0.27. The final CAT distinguished between 16 levels of MCL performance by presenting an average of 10.61  ± 1.00 items per patient, with an average completion time of 3:04 ± 1:24 min. Signs of convergent validity showed a correlation of 0.73 and repeatability was assessed showing an intraclass Correlation Coefficient of 0.881 with a 95% Confidence Interval 0,815-0,924, and Limits of Agreement of  ± 1.07.</p><p><strong>Conclusion: </strong>The MCL-PRO-CAT is a groundbreaking tool for evaluating MCL performance in presbyopic individuals. With automated scoring and fewer items, it was feasible, valid, and precise, enhancing clinical practicality.</p>\",\"PeriodicalId\":49087,\"journal\":{\"name\":\"Contact Lens & Anterior Eye\",\"volume\":\" \",\"pages\":\"102378\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2025-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contact Lens & Anterior Eye\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.clae.2025.102378\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clae.2025.102378","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development and Initial Validation of the MCL-PRO-CAT: A computerized adaptive test designed to measure multifocal contact lens performance from the patient's perspective.

Purpose: To create a valid and reliable computer-adaptive testing (CAT) tool for assessing Multifocal Contact Lens (MCL) performance in presbyopic individuals, ensuring high precision. The self-administered tool will initially be accessible online in Spanish.

Methods: Five steps were followed for the correct development of the instruments: item bank development, item refinement phase, item response theory calibration of the refined item bank, CAT simulations and design, and an initial validation study. A total of 1163 presbyopic patients were involved in the over-all study. Convergent validity was assessed by comparing results to the CLDQ-8 questionnaire, and repeatability assessment was performed two weeks after the initial completion.

Results: The final item bank consisted of 108 items assessing various relevant domains for MCL performance evaluation. The calibration study showed a person separation index of 4.69 and a reliability of 0.96 along with a measurement precision of 0.27. The final CAT distinguished between 16 levels of MCL performance by presenting an average of 10.61  ± 1.00 items per patient, with an average completion time of 3:04 ± 1:24 min. Signs of convergent validity showed a correlation of 0.73 and repeatability was assessed showing an intraclass Correlation Coefficient of 0.881 with a 95% Confidence Interval 0,815-0,924, and Limits of Agreement of  ± 1.07.

Conclusion: The MCL-PRO-CAT is a groundbreaking tool for evaluating MCL performance in presbyopic individuals. With automated scoring and fewer items, it was feasible, valid, and precise, enhancing clinical practicality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
期刊最新文献
Rodent models for dry eye syndrome (DES). Ethnicity optimized indices enhance the diagnostic efficiency of early Keratoconus: A multicenter validation study. Evaluation of large language models for providing educational information in orthokeratology care. Assessing scleral toricity induced lens flexure and contact disparity using anterior segment optical coherence tomography. Designing a contact lens with atropine base using a microemulsion technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1