基于介电弹性体致动器的泵送:设计与表征

IF 3.6 3区 材料科学 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY Advanced Engineering Materials Pub Date : 2025-01-21 DOI:10.1002/adem.202570005
Amine Benouhiba, Armando Walter, Silje Ekroll Jahren, Francesco Clavica, Dominik Obrist, Yoan Civet, Yves Perriard
{"title":"基于介电弹性体致动器的泵送:设计与表征","authors":"Amine Benouhiba,&nbsp;Armando Walter,&nbsp;Silje Ekroll Jahren,&nbsp;Francesco Clavica,&nbsp;Dominik Obrist,&nbsp;Yoan Civet,&nbsp;Yves Perriard","doi":"10.1002/adem.202570005","DOIUrl":null,"url":null,"abstract":"<p><b>Dielectric Elastomer Actuators</b>\n </p><p>In article number 2401306, Amine Benouhiba and co-workers present a high-performance tubular dielectric elastomer pump optimized for heart assist applications. Operating at pressures of 15, 70, and 120 mmHg, it achieves a flow rate of 6.5 L min<sup>–1</sup> and a pressure head of 27.5 mmHg, underscoring its potential to enhance fluid circulation and support cardiovascular function in medical applications.\n <figure>\n <div><picture>\n <source></source></picture><p></p>\n </div>\n </figure></p>","PeriodicalId":7275,"journal":{"name":"Advanced Engineering Materials","volume":"27 2","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adem.202570005","citationCount":"0","resultStr":"{\"title\":\"Breaking the Cardiovascular Flow Barrier for Dielectric Elastomer Actuator-Based Pumping: Design and Characterization\",\"authors\":\"Amine Benouhiba,&nbsp;Armando Walter,&nbsp;Silje Ekroll Jahren,&nbsp;Francesco Clavica,&nbsp;Dominik Obrist,&nbsp;Yoan Civet,&nbsp;Yves Perriard\",\"doi\":\"10.1002/adem.202570005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><b>Dielectric Elastomer Actuators</b>\\n </p><p>In article number 2401306, Amine Benouhiba and co-workers present a high-performance tubular dielectric elastomer pump optimized for heart assist applications. Operating at pressures of 15, 70, and 120 mmHg, it achieves a flow rate of 6.5 L min<sup>–1</sup> and a pressure head of 27.5 mmHg, underscoring its potential to enhance fluid circulation and support cardiovascular function in medical applications.\\n <figure>\\n <div><picture>\\n <source></source></picture><p></p>\\n </div>\\n </figure></p>\",\"PeriodicalId\":7275,\"journal\":{\"name\":\"Advanced Engineering Materials\",\"volume\":\"27 2\",\"pages\":\"\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2025-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adem.202570005\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Engineering Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://advanced.onlinelibrary.wiley.com/doi/10.1002/adem.202570005\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Engineering Materials","FirstCategoryId":"88","ListUrlMain":"https://advanced.onlinelibrary.wiley.com/doi/10.1002/adem.202570005","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在2401306号文章中,Amine Benouhiba及其同事介绍了一种针对心脏辅助应用进行优化的高性能管状介电弹性体泵。在15、70和120 mmHg的压力下工作,它的流速为6.5 L min-1,压头为27.5 mmHg,强调了其在医疗应用中增强液体循环和支持心血管功能的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Breaking the Cardiovascular Flow Barrier for Dielectric Elastomer Actuator-Based Pumping: Design and Characterization

Dielectric Elastomer Actuators

In article number 2401306, Amine Benouhiba and co-workers present a high-performance tubular dielectric elastomer pump optimized for heart assist applications. Operating at pressures of 15, 70, and 120 mmHg, it achieves a flow rate of 6.5 L min–1 and a pressure head of 27.5 mmHg, underscoring its potential to enhance fluid circulation and support cardiovascular function in medical applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advanced Engineering Materials
Advanced Engineering Materials 工程技术-材料科学:综合
CiteScore
5.70
自引率
5.60%
发文量
544
审稿时长
1.7 months
期刊介绍: Advanced Engineering Materials is the membership journal of three leading European Materials Societies - German Materials Society/DGM, - French Materials Society/SF2M, - Swiss Materials Federation/SVMT.
期刊最新文献
Issue Information Incorporation of Selenium into Sol–Gel-Derived Bioactive Glass: Influence on Glass Structure, Bioactivity, and its Selective Cytotoxicity Functional Bioinks for Dental Tissue Engineering: Design Principles, Mechanisms, and Applications Tuning Aluminum Content to Enhance Stress Rupture Properties of High-Tungsten Superalloy From Polymer-Continuous to Particle-Continuous: Coupled Acoustic–Dielectric Behavior of Al2O3/Epoxy Composites for Gas Insulated Switchgear Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1