PM 7/76 (6) 使用 EPPO 诊断标准

Q3 Agricultural and Biological Sciences EPPO Bulletin Pub Date : 2024-11-16 DOI:10.1111/epp.13046
{"title":"PM 7/76 (6) 使用 EPPO 诊断标准","authors":"","doi":"10.1111/epp.13046","DOIUrl":null,"url":null,"abstract":"<p>This Standard describes the purpose and use of EPPO Diagnostic Standards. Definitions used in these Standards are given in Appendix 1. This Standard is based on ISPM 27 (IPPC, <span>2006</span>).</p><p>Approved in 2006-09. Revised in 2010-09, 2014-09, 2016-11, 2018-09 and in 2024-09.</p><p>This Standard is designed to be used in conjunction with the EPPO Standards of series PM 7 on diagnostics.</p><p>Diagnostic tests have different performance characteristics (e.g. levels of analytical sensitivity and analytical specificity resulting in different risks of false-positive and false-negative results), speed and cost. These elements are taken into account by the customer and the laboratory when choosing a test or a combination of tests for the diagnosis of a pest in specific circumstances of use.</p><p>The reliability of a test depends on its performance characteristics, obtained from validation and verification studies. Information on how to perform validation and verification is provided in PM 7/98 <i>Specific requirements for laboratories preparing accreditation for a plant pest diagnostic activity</i> (EPPO, <span>2021</span>). Validation data is not available for all tests that are currently widely used in plant pest diagnostic laboratories. Lack of validation data is, in particular, often the case for routine tests such as ELISA or morphological analyses. However, there is often a long period of experience of use of such tests and it is usually possible for the laboratory to qualify the reliability of such tests (e.g. based on the number of years of experience, the number of samples tested, the use of controls and participation in proficiency tests). It is nevertheless recognized that performance characteristics allow a better understanding of the reliability of the tests. There are cases where a combination of tests is used to increase the overall accuracy and confidence in the diagnosis (e.g. see Section 4).</p><p>It should be noted that the result of a test or a combination of tests also depends on the proficiency of the laboratory.</p><p>Critical cases:</p><p>The circumstances of use described in the latter three bullet points (in bold) are considered in this Standard as critical cases where additional confidence in the outcome of the diagnosis will be required (see Section 2.1). The detection of a pest in a consignment declared to have been submitted to a phytosanitary treatment is also considered to be a critical case (see also Section 5.3.2).</p>","PeriodicalId":34952,"journal":{"name":"EPPO Bulletin","volume":"54 3","pages":"312-316"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/epp.13046","citationCount":"0","resultStr":"{\"title\":\"PM 7/76 (6) Use of EPPO Diagnostic Standards\",\"authors\":\"\",\"doi\":\"10.1111/epp.13046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This Standard describes the purpose and use of EPPO Diagnostic Standards. Definitions used in these Standards are given in Appendix 1. This Standard is based on ISPM 27 (IPPC, <span>2006</span>).</p><p>Approved in 2006-09. Revised in 2010-09, 2014-09, 2016-11, 2018-09 and in 2024-09.</p><p>This Standard is designed to be used in conjunction with the EPPO Standards of series PM 7 on diagnostics.</p><p>Diagnostic tests have different performance characteristics (e.g. levels of analytical sensitivity and analytical specificity resulting in different risks of false-positive and false-negative results), speed and cost. These elements are taken into account by the customer and the laboratory when choosing a test or a combination of tests for the diagnosis of a pest in specific circumstances of use.</p><p>The reliability of a test depends on its performance characteristics, obtained from validation and verification studies. Information on how to perform validation and verification is provided in PM 7/98 <i>Specific requirements for laboratories preparing accreditation for a plant pest diagnostic activity</i> (EPPO, <span>2021</span>). Validation data is not available for all tests that are currently widely used in plant pest diagnostic laboratories. Lack of validation data is, in particular, often the case for routine tests such as ELISA or morphological analyses. However, there is often a long period of experience of use of such tests and it is usually possible for the laboratory to qualify the reliability of such tests (e.g. based on the number of years of experience, the number of samples tested, the use of controls and participation in proficiency tests). It is nevertheless recognized that performance characteristics allow a better understanding of the reliability of the tests. There are cases where a combination of tests is used to increase the overall accuracy and confidence in the diagnosis (e.g. see Section 4).</p><p>It should be noted that the result of a test or a combination of tests also depends on the proficiency of the laboratory.</p><p>Critical cases:</p><p>The circumstances of use described in the latter three bullet points (in bold) are considered in this Standard as critical cases where additional confidence in the outcome of the diagnosis will be required (see Section 2.1). The detection of a pest in a consignment declared to have been submitted to a phytosanitary treatment is also considered to be a critical case (see also Section 5.3.2).</p>\",\"PeriodicalId\":34952,\"journal\":{\"name\":\"EPPO Bulletin\",\"volume\":\"54 3\",\"pages\":\"312-316\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/epp.13046\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EPPO Bulletin\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/epp.13046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Agricultural and Biological Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EPPO Bulletin","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/epp.13046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PM 7/76 (6) Use of EPPO Diagnostic Standards

This Standard describes the purpose and use of EPPO Diagnostic Standards. Definitions used in these Standards are given in Appendix 1. This Standard is based on ISPM 27 (IPPC, 2006).

Approved in 2006-09. Revised in 2010-09, 2014-09, 2016-11, 2018-09 and in 2024-09.

This Standard is designed to be used in conjunction with the EPPO Standards of series PM 7 on diagnostics.

Diagnostic tests have different performance characteristics (e.g. levels of analytical sensitivity and analytical specificity resulting in different risks of false-positive and false-negative results), speed and cost. These elements are taken into account by the customer and the laboratory when choosing a test or a combination of tests for the diagnosis of a pest in specific circumstances of use.

The reliability of a test depends on its performance characteristics, obtained from validation and verification studies. Information on how to perform validation and verification is provided in PM 7/98 Specific requirements for laboratories preparing accreditation for a plant pest diagnostic activity (EPPO, 2021). Validation data is not available for all tests that are currently widely used in plant pest diagnostic laboratories. Lack of validation data is, in particular, often the case for routine tests such as ELISA or morphological analyses. However, there is often a long period of experience of use of such tests and it is usually possible for the laboratory to qualify the reliability of such tests (e.g. based on the number of years of experience, the number of samples tested, the use of controls and participation in proficiency tests). It is nevertheless recognized that performance characteristics allow a better understanding of the reliability of the tests. There are cases where a combination of tests is used to increase the overall accuracy and confidence in the diagnosis (e.g. see Section 4).

It should be noted that the result of a test or a combination of tests also depends on the proficiency of the laboratory.

Critical cases:

The circumstances of use described in the latter three bullet points (in bold) are considered in this Standard as critical cases where additional confidence in the outcome of the diagnosis will be required (see Section 2.1). The detection of a pest in a consignment declared to have been submitted to a phytosanitary treatment is also considered to be a critical case (see also Section 5.3.2).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
EPPO Bulletin
EPPO Bulletin Agricultural and Biological Sciences-Horticulture
CiteScore
1.80
自引率
0.00%
发文量
70
期刊介绍: As the official publication of the European and Mediterranean Plant Protection Organization, the EPPO Bulletin publishes research findings on all aspects of plant protection, but particularly those of immediate concern to government plant protection services. Papers are published in English and French, with summaries also in Russian.
期刊最新文献
Issue Information Annual Report and Council Recommendations 2023 Introduction to PM 7 Standards on Diagnostics Introduction to PM 9 Standards on National regulatory control systems Introduction to PM 6 Standards on Safe use of biological control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1