基于eg修饰PEDOT:PSS有机电化学晶体管的唾液多离子原位测定芯片

IF 4.7 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2025-01-29 DOI:10.1021/acsaelm.4c01806
Yamujin Jang, June-Heang Choi, Soo-Hyun Lee and Yi-Jae Lee*, 
{"title":"基于eg修饰PEDOT:PSS有机电化学晶体管的唾液多离子原位测定芯片","authors":"Yamujin Jang,&nbsp;June-Heang Choi,&nbsp;Soo-Hyun Lee and Yi-Jae Lee*,&nbsp;","doi":"10.1021/acsaelm.4c01806","DOIUrl":null,"url":null,"abstract":"<p >In this study, the multi-ion detection chip (MIDC) with an ethylene glycol-modified PEDOT:PSS (EGPP)-based organic electrochemical transistor (OECT) was designed, fabricated, and characterized for in situ salivary ion determination applications. As the channel material for the OECT, EGPP was selectively coated onto the patterned drain and source electrodes. The fabrication sequence was performed using a semiconductor batch process. With wafer-scale processing, the fabricated unit MIDC (10 × 10 mm<sup>2</sup>) with EGPP-based OECT coated with ion selective membrane (ISM) as sensing layers measures the concentration of K<sup>+</sup>, Na<sup>+</sup>, Ca<sup>2+</sup>, and Cl<sup>–</sup> concentration range lower than 10<sup>–5</sup> M to a resolution of ∼2 × 10<sup>–3</sup> log concentration range. These ions were selected because of their prominence in body metabolism. We used the 4-different channel for selective multi-ion determination, and an additional 1-channel array was used for salivary glucose determination. Because all of the sensing layers simultaneously measured the same analyte solution, we investigated its resistance to interference among the analytes. Additionally, we evaluated its practical feasibility from the response of multi-ions in an artificial saliva sample. The performance of this chip platform is suitable for applications such as personalized in situ healthcare and water quality monitoring.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"7 3","pages":"1039–1048 1039–1048"},"PeriodicalIF":4.7000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Situ Salivary Multi-Ion Determination Chip Based on an Organic Electrochemical Transistor with EG-Modified PEDOT:PSS\",\"authors\":\"Yamujin Jang,&nbsp;June-Heang Choi,&nbsp;Soo-Hyun Lee and Yi-Jae Lee*,&nbsp;\",\"doi\":\"10.1021/acsaelm.4c01806\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >In this study, the multi-ion detection chip (MIDC) with an ethylene glycol-modified PEDOT:PSS (EGPP)-based organic electrochemical transistor (OECT) was designed, fabricated, and characterized for in situ salivary ion determination applications. As the channel material for the OECT, EGPP was selectively coated onto the patterned drain and source electrodes. The fabrication sequence was performed using a semiconductor batch process. With wafer-scale processing, the fabricated unit MIDC (10 × 10 mm<sup>2</sup>) with EGPP-based OECT coated with ion selective membrane (ISM) as sensing layers measures the concentration of K<sup>+</sup>, Na<sup>+</sup>, Ca<sup>2+</sup>, and Cl<sup>–</sup> concentration range lower than 10<sup>–5</sup> M to a resolution of ∼2 × 10<sup>–3</sup> log concentration range. These ions were selected because of their prominence in body metabolism. We used the 4-different channel for selective multi-ion determination, and an additional 1-channel array was used for salivary glucose determination. Because all of the sensing layers simultaneously measured the same analyte solution, we investigated its resistance to interference among the analytes. Additionally, we evaluated its practical feasibility from the response of multi-ions in an artificial saliva sample. The performance of this chip platform is suitable for applications such as personalized in situ healthcare and water quality monitoring.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":\"7 3\",\"pages\":\"1039–1048 1039–1048\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-01-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acsaelm.4c01806\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"88","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsaelm.4c01806","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本研究设计、制作了乙二醇修饰的PEDOT:PSS (EGPP)基有机电化学晶体管(OECT)多离子检测芯片(MIDC),并对其进行了表征,用于唾液离子的原位检测。作为OECT的通道材料,EGPP被选择性地涂覆在有图案的漏极和源极上。制造顺序是使用半导体批工艺进行的。通过晶圆级加工,制备的单元MIDC (10 × 10 mm2)与涂有离子选择膜(ISM)的egpp基OECT作为传感层,测量K+, Na+, Ca2+和Cl -浓度范围低于10 - 5 M的浓度,分辨率为~ 2 × 10 - 3 log浓度范围。选择这些离子是因为它们在机体代谢中的重要作用。我们使用4个不同的通道进行选择性多离子测定,并使用一个额外的1通道阵列进行唾液葡萄糖测定。由于所有的传感层同时测量相同的分析物溶液,我们研究了其对分析物之间干扰的抵抗。此外,我们还从人工唾液样品中多离子的响应来评估其实际可行性。该芯片平台的性能适用于个性化现场医疗保健和水质监测等应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In Situ Salivary Multi-Ion Determination Chip Based on an Organic Electrochemical Transistor with EG-Modified PEDOT:PSS

In this study, the multi-ion detection chip (MIDC) with an ethylene glycol-modified PEDOT:PSS (EGPP)-based organic electrochemical transistor (OECT) was designed, fabricated, and characterized for in situ salivary ion determination applications. As the channel material for the OECT, EGPP was selectively coated onto the patterned drain and source electrodes. The fabrication sequence was performed using a semiconductor batch process. With wafer-scale processing, the fabricated unit MIDC (10 × 10 mm2) with EGPP-based OECT coated with ion selective membrane (ISM) as sensing layers measures the concentration of K+, Na+, Ca2+, and Cl concentration range lower than 10–5 M to a resolution of ∼2 × 10–3 log concentration range. These ions were selected because of their prominence in body metabolism. We used the 4-different channel for selective multi-ion determination, and an additional 1-channel array was used for salivary glucose determination. Because all of the sensing layers simultaneously measured the same analyte solution, we investigated its resistance to interference among the analytes. Additionally, we evaluated its practical feasibility from the response of multi-ions in an artificial saliva sample. The performance of this chip platform is suitable for applications such as personalized in situ healthcare and water quality monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊介绍: ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric. Indexed/​Abstracted: Web of Science SCIE Scopus CAS INSPEC Portico
期刊最新文献
Issue Publication Information Issue Editorial Masthead High-Precision Multigas Detection Based on Pd–Au Bimetallic Decorated ZnO Gas Sensors and PSO Feature Optimization Field-Induced Enhancement of Ferroelectric Switching in Hf0.5Zr0.5O2 Capacitors under Cryogenic Conditions Interface-Driven Bipolar Resistive Switching with Intrinsic Self-Rectifying Behavior in a p-LaCrO3/n-Si Heterostructure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1