随干涉图刷新率变化的自由运行双梳光谱的自校正

IF 2.4 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Photonics Journal Pub Date : 2025-01-27 DOI:10.1109/JPHOT.2025.3534022
Xiangze Ma;Wei Long;Jie Cheng;Yujia Ji;Teng Huang;Dijun Chen
{"title":"随干涉图刷新率变化的自由运行双梳光谱的自校正","authors":"Xiangze Ma;Wei Long;Jie Cheng;Yujia Ji;Teng Huang;Dijun Chen","doi":"10.1109/JPHOT.2025.3534022","DOIUrl":null,"url":null,"abstract":"The dual-comb spectrometer has emerged as a preferred instrument in multiheterodyne spectroscopy due to its high-resolution and fast-scanning capabilities. Conventional dual-comb spectroscopy (DCS) requires locking or reference systems, increasing both system complexity and cost, and limiting its commercial feasibility. Self-correction offers a promising alternative, though it demands a high refresh rate for interferograms (IGMs), corresponding to the repetition frequency difference, to counter system noise. This study examined the practical effects of self-correction at various refresh rates by measuring <inline-formula><tex-math>$\\rm H^{13}C^{14}N$</tex-math></inline-formula> absorption. The results indicate that higher repetition frequency differences improve self-correction performance, while lower repetition frequencies cause deviations in absorption line width and intensity. Practical applications must balance measurement bandwidth, which is constrained by the repetition frequency difference.","PeriodicalId":13204,"journal":{"name":"IEEE Photonics Journal","volume":"17 1","pages":"1-5"},"PeriodicalIF":2.4000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10854615","citationCount":"0","resultStr":"{\"title\":\"Self-Correction in Free-Running Dual-Comb Spectroscopy With Varying Interferogram Refresh Rates\",\"authors\":\"Xiangze Ma;Wei Long;Jie Cheng;Yujia Ji;Teng Huang;Dijun Chen\",\"doi\":\"10.1109/JPHOT.2025.3534022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dual-comb spectrometer has emerged as a preferred instrument in multiheterodyne spectroscopy due to its high-resolution and fast-scanning capabilities. Conventional dual-comb spectroscopy (DCS) requires locking or reference systems, increasing both system complexity and cost, and limiting its commercial feasibility. Self-correction offers a promising alternative, though it demands a high refresh rate for interferograms (IGMs), corresponding to the repetition frequency difference, to counter system noise. This study examined the practical effects of self-correction at various refresh rates by measuring <inline-formula><tex-math>$\\\\rm H^{13}C^{14}N$</tex-math></inline-formula> absorption. The results indicate that higher repetition frequency differences improve self-correction performance, while lower repetition frequencies cause deviations in absorption line width and intensity. Practical applications must balance measurement bandwidth, which is constrained by the repetition frequency difference.\",\"PeriodicalId\":13204,\"journal\":{\"name\":\"IEEE Photonics Journal\",\"volume\":\"17 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-01-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10854615\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Photonics Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10854615/\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Photonics Journal","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10854615/","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

由于其高分辨率和快速扫描能力,双梳光谱仪已成为多外差光谱的首选仪器。传统的双梳光谱(DCS)需要锁定或参考系统,增加了系统的复杂性和成本,限制了其商业可行性。自校正提供了一个很有前途的替代方案,尽管它需要干涉图(igm)的高刷新率,对应于重复频率差,以对抗系统噪声。本研究通过测量$\rm H^{13}C^{14}N$吸收率,考察了在不同刷新率下自校正的实际效果。结果表明,较高的重复频率差提高了自校正性能,而较低的重复频率差会导致吸收线宽度和强度的偏差。实际应用中必须平衡测量带宽,而测量带宽受重复频率差的限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Self-Correction in Free-Running Dual-Comb Spectroscopy With Varying Interferogram Refresh Rates
The dual-comb spectrometer has emerged as a preferred instrument in multiheterodyne spectroscopy due to its high-resolution and fast-scanning capabilities. Conventional dual-comb spectroscopy (DCS) requires locking or reference systems, increasing both system complexity and cost, and limiting its commercial feasibility. Self-correction offers a promising alternative, though it demands a high refresh rate for interferograms (IGMs), corresponding to the repetition frequency difference, to counter system noise. This study examined the practical effects of self-correction at various refresh rates by measuring $\rm H^{13}C^{14}N$ absorption. The results indicate that higher repetition frequency differences improve self-correction performance, while lower repetition frequencies cause deviations in absorption line width and intensity. Practical applications must balance measurement bandwidth, which is constrained by the repetition frequency difference.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Photonics Journal
IEEE Photonics Journal ENGINEERING, ELECTRICAL & ELECTRONIC-OPTICS
CiteScore
4.50
自引率
8.30%
发文量
489
审稿时长
1.4 months
期刊介绍: Breakthroughs in the generation of light and in its control and utilization have given rise to the field of Photonics, a rapidly expanding area of science and technology with major technological and economic impact. Photonics integrates quantum electronics and optics to accelerate progress in the generation of novel photon sources and in their utilization in emerging applications at the micro and nano scales spanning from the far-infrared/THz to the x-ray region of the electromagnetic spectrum. IEEE Photonics Journal is an online-only journal dedicated to the rapid disclosure of top-quality peer-reviewed research at the forefront of all areas of photonics. Contributions addressing issues ranging from fundamental understanding to emerging technologies and applications are within the scope of the Journal. The Journal includes topics in: Photon sources from far infrared to X-rays, Photonics materials and engineered photonic structures, Integrated optics and optoelectronic, Ultrafast, attosecond, high field and short wavelength photonics, Biophotonics, including DNA photonics, Nanophotonics, Magnetophotonics, Fundamentals of light propagation and interaction; nonlinear effects, Optical data storage, Fiber optics and optical communications devices, systems, and technologies, Micro Opto Electro Mechanical Systems (MOEMS), Microwave photonics, Optical Sensors.
期刊最新文献
Performance Analysis of Hybrid FSO/RF-THz Relay Communication System Bandwidth-Tunable Mode-Locked Fiber Laser Enabled by Hetero-Core Offset-Spliced GIMF Saturable Absorber Study of Random Lasing in High-Power Narrow-Band ASE Sources Quantitative Evaluation of Physical-Layer Security in Bidirectional Chaotic Optical Communication Systems Cross-Layer Q-Learning Routing for VLC-Enhanced Wireless Mesh Networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1