{"title":"利用非破坏性故障参数监测油浸式电力变压器绕组纸绝缘健康状况的新型模糊方法","authors":"Md. Manzar Nezami,&nbsp;Hythem Hashem,&nbsp;Md. Danish Equbal,&nbsp;Shakeb A. Khan,&nbsp;Hasmat Malik,&nbsp;Fausto Pedro García Márquez,&nbsp;Asyraf Afthanorhan,&nbsp;Mohammad Asef Hossaini","doi":"10.1049/elp2.12533","DOIUrl":null,"url":null,"abstract":"<p>Power transformers, a significant and critical component of power system, require regular condition monitoring by the utilities for uninterrupted power supply. The kraft paper made of cellulose is used as the solid insulation of the transformer which undergoes thermal, electrical and environmental stresses causing its progressive ageing. It thereby reduces the physical strength of the paper and ultimately affects the transformer's remaining useful life (RUL). The current state (physical) of the cellulosic (solid) insulating paper is predicted in this article using the fuzzy inference system (FIS) based RUL assessment technique. Three non-destructive parameters, that is, 2-Furfuraldehyde (2-FAL), Carbon Monoxide (CO) and Carbon dioxide (CO<sub>2</sub>) are used to determine the value of the Degree of Polymerisation (i.e. DP) which directly reflects the current physical state of the insulating material. Four states (Healthy, Poor, Very Poor, and Worst) of the insulating paper are identified based on the values of DP. Five FIS models have been developed separately with different membership functions and a number of fuzzy if-then rules are formulated to estimate the value of DP. Every model is tested with 30 test samples to validate the system accuracy. The physical condition of the insulation estimated using FIS built with trapezoidal membership function has been found to be considerably precise with an average absolute deviation of 0.33%. Hence, a comprehensive assessment of transformer's health is carried out with the prominent non-destructive parameters.</p>","PeriodicalId":13352,"journal":{"name":"Iet Electric Power Applications","volume":"19 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12533","citationCount":"0","resultStr":"{\"title\":\"A novel fuzzy approach for winding paper insulation health monitoring of oil-immersed power transformer using non-destructive failure parameters\",\"authors\":\"Md. Manzar Nezami,&nbsp;Hythem Hashem,&nbsp;Md. Danish Equbal,&nbsp;Shakeb A. Khan,&nbsp;Hasmat Malik,&nbsp;Fausto Pedro García Márquez,&nbsp;Asyraf Afthanorhan,&nbsp;Mohammad Asef Hossaini\",\"doi\":\"10.1049/elp2.12533\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Power transformers, a significant and critical component of power system, require regular condition monitoring by the utilities for uninterrupted power supply. The kraft paper made of cellulose is used as the solid insulation of the transformer which undergoes thermal, electrical and environmental stresses causing its progressive ageing. It thereby reduces the physical strength of the paper and ultimately affects the transformer's remaining useful life (RUL). The current state (physical) of the cellulosic (solid) insulating paper is predicted in this article using the fuzzy inference system (FIS) based RUL assessment technique. Three non-destructive parameters, that is, 2-Furfuraldehyde (2-FAL), Carbon Monoxide (CO) and Carbon dioxide (CO<sub>2</sub>) are used to determine the value of the Degree of Polymerisation (i.e. DP) which directly reflects the current physical state of the insulating material. Four states (Healthy, Poor, Very Poor, and Worst) of the insulating paper are identified based on the values of DP. Five FIS models have been developed separately with different membership functions and a number of fuzzy if-then rules are formulated to estimate the value of DP. Every model is tested with 30 test samples to validate the system accuracy. The physical condition of the insulation estimated using FIS built with trapezoidal membership function has been found to be considerably precise with an average absolute deviation of 0.33%. Hence, a comprehensive assessment of transformer's health is carried out with the prominent non-destructive parameters.</p>\",\"PeriodicalId\":13352,\"journal\":{\"name\":\"Iet Electric Power Applications\",\"volume\":\"19 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12533\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Electric Power Applications\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12533\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Electric Power Applications","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12533","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel fuzzy approach for winding paper insulation health monitoring of oil-immersed power transformer using non-destructive failure parameters

Power transformers, a significant and critical component of power system, require regular condition monitoring by the utilities for uninterrupted power supply. The kraft paper made of cellulose is used as the solid insulation of the transformer which undergoes thermal, electrical and environmental stresses causing its progressive ageing. It thereby reduces the physical strength of the paper and ultimately affects the transformer's remaining useful life (RUL). The current state (physical) of the cellulosic (solid) insulating paper is predicted in this article using the fuzzy inference system (FIS) based RUL assessment technique. Three non-destructive parameters, that is, 2-Furfuraldehyde (2-FAL), Carbon Monoxide (CO) and Carbon dioxide (CO2) are used to determine the value of the Degree of Polymerisation (i.e. DP) which directly reflects the current physical state of the insulating material. Four states (Healthy, Poor, Very Poor, and Worst) of the insulating paper are identified based on the values of DP. Five FIS models have been developed separately with different membership functions and a number of fuzzy if-then rules are formulated to estimate the value of DP. Every model is tested with 30 test samples to validate the system accuracy. The physical condition of the insulation estimated using FIS built with trapezoidal membership function has been found to be considerably precise with an average absolute deviation of 0.33%. Hence, a comprehensive assessment of transformer's health is carried out with the prominent non-destructive parameters.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iet Electric Power Applications
Iet Electric Power Applications 工程技术-工程:电子与电气
CiteScore
4.80
自引率
5.90%
发文量
104
审稿时长
3 months
期刊介绍: IET Electric Power Applications publishes papers of a high technical standard with a suitable balance of practice and theory. The scope covers a wide range of applications and apparatus in the power field. In addition to papers focussing on the design and development of electrical equipment, papers relying on analysis are also sought, provided that the arguments are conveyed succinctly and the conclusions are clear. The scope of the journal includes the following: The design and analysis of motors and generators of all sizes Rotating electrical machines Linear machines Actuators Power transformers Railway traction machines and drives Variable speed drives Machines and drives for electrically powered vehicles Industrial and non-industrial applications and processes Current Special Issue. Call for papers: Progress in Electric Machines, Power Converters and their Control for Wave Energy Generation - https://digital-library.theiet.org/files/IET_EPA_CFP_PEMPCCWEG.pdf
期刊最新文献
Thermal Analysis of Outer Rotor PMSM Based on Flat Heat Pipe Cooling Method Predictive AI Maintenance of Distribution Oil-Immersed Transformer via Multimodal Data Fusion: A New Dynamic Multiscale Attention CNN-LSTM Anomaly Detection Model for Industrial Energy Management Direct model predictive torque control for permanent magnet synchronous motor with voltage vector parallel optimisation algorithm DeepServo: Deep learning-enhanced state feedback for robust servo system control Analytical model for ring winding axial flux permanent magnet motor using Schwarz–Christoffel conformal mapping
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1