Hang Zhou , Kexin Sun , Zhenna Lu , Hao Li , Xiaocong Ai , Jin Zhang , Xingtao Huang , Jianbei Liu
{"title":"STCF 探测器中基于 Hough 变换的全局轨迹搜索","authors":"Hang Zhou , Kexin Sun , Zhenna Lu , Hao Li , Xiaocong Ai , Jin Zhang , Xingtao Huang , Jianbei Liu","doi":"10.1016/j.nima.2025.170357","DOIUrl":null,"url":null,"abstract":"<div><div>The proposed Super Tau-Charm Facility (STCF) is an electron-positron collider designed to operate in a center-of-mass energy range from 2 to 7 GeV. It provides a unique platform for physics research in the tau-charm energy region. To fulfill the physics goals of STCF, high tracking efficiency and good momentum resolution is required for charged particles with momenta from 50 MeV/c to 3.5 GeV/c. A global track finding algorithm based on Hough transform has been developed and implemented in the STCF software framework to meet this requirement. The design of the algorithm and its performance with simulation are presented in this paper.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1075 ","pages":"Article 170357"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Global track finding based on the Hough transform in the STCF detector\",\"authors\":\"Hang Zhou , Kexin Sun , Zhenna Lu , Hao Li , Xiaocong Ai , Jin Zhang , Xingtao Huang , Jianbei Liu\",\"doi\":\"10.1016/j.nima.2025.170357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The proposed Super Tau-Charm Facility (STCF) is an electron-positron collider designed to operate in a center-of-mass energy range from 2 to 7 GeV. It provides a unique platform for physics research in the tau-charm energy region. To fulfill the physics goals of STCF, high tracking efficiency and good momentum resolution is required for charged particles with momenta from 50 MeV/c to 3.5 GeV/c. A global track finding algorithm based on Hough transform has been developed and implemented in the STCF software framework to meet this requirement. The design of the algorithm and its performance with simulation are presented in this paper.</div></div>\",\"PeriodicalId\":19359,\"journal\":{\"name\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"volume\":\"1075 \",\"pages\":\"Article 170357\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0168900225001585\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900225001585","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Global track finding based on the Hough transform in the STCF detector
The proposed Super Tau-Charm Facility (STCF) is an electron-positron collider designed to operate in a center-of-mass energy range from 2 to 7 GeV. It provides a unique platform for physics research in the tau-charm energy region. To fulfill the physics goals of STCF, high tracking efficiency and good momentum resolution is required for charged particles with momenta from 50 MeV/c to 3.5 GeV/c. A global track finding algorithm based on Hough transform has been developed and implemented in the STCF software framework to meet this requirement. The design of the algorithm and its performance with simulation are presented in this paper.
期刊介绍:
Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section.
Theoretical as well as experimental papers are accepted.