时间、抗凝剂和检测通道对乙二胺四乙酸(EDTA)依赖性假性血小板减少症患者血小板计数的影响。

IF 2.4 3区 生物学 Q2 MULTIDISCIPLINARY SCIENCES PeerJ Pub Date : 2025-03-04 eCollection Date: 2025-01-01 DOI:10.7717/peerj.19103
Yu Zhang, Bei Chen, Jiaoying Feng, Wen Yu, Wei Liang, Meifen Li, Guanghua Zhai, Meina Yan
{"title":"时间、抗凝剂和检测通道对乙二胺四乙酸(EDTA)依赖性假性血小板减少症患者血小板计数的影响。","authors":"Yu Zhang, Bei Chen, Jiaoying Feng, Wen Yu, Wei Liang, Meifen Li, Guanghua Zhai, Meina Yan","doi":"10.7717/peerj.19103","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>EDTA-dependent pseudothrombocytopenia (EDTA-PTCP) is an <i>in vitro</i> phenomenon that may lead to expensive, time-consuming, and invasive diagnostic procedures as well as unnecessary patient treatment. The purpose of this study was to explore the effects of time, anticoagulant and detection channel on the platelet (PLT) count of EDTA-PTCP samples, and to suggest a better method for correcting spurious low PLT counts.</p><p><strong>Methods: </strong>In this study, 43 identified EDTA-PTCP samples were collected. The Sysmex XN-9100, Mindray BC-6900 and Mindray BC-5390 haematology analysers were used to test these EDTA-PTCP samples on the following detection channels at different time points: PLT count by impedance method (PLT-I), PLT count by optical method (PLT-O) and PLT count by fluorescent staining (PLT-F).</p><p><strong>Results: </strong>EDTA-PTCP was time-dependent and small PLT agglutination occurred in most of the corresponding citrate-treated samples. Our results further demonstrated that the detection channel significantly affected the PLT count of the EDTA-PTCP samples. The XN-9100 PLT-F channel exhibited a greater dissociative effect than the XN-9100 PLT-I and PLT-O channels. Moreover, blood samples processed in the PLT-O channel of the Mindray hematology analyzer showed the highest PLT count in EDTA-K2 tubes compared to the other detection channels.</p><p><strong>Conclusion: </strong>Our data showed that time, anticoagulant and detection channel significantly affected the PLT count in the EDTA-PTCP samples. For the EDTA-PTCP samples, the simplest retest method was to use the PLT-O channel of the Mindray automatic blood analyser within 30 min. In addition, changing the sodium citrate anticoagulant and using the XN-9100 PLT-F channel within 15 min were also suitable for correcting the spurious low PLT of the EDTA-PTCP samples.</p>","PeriodicalId":19799,"journal":{"name":"PeerJ","volume":"13 ","pages":"e19103"},"PeriodicalIF":2.4000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11887562/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of time, anticoagulant and detection channel on platelet count in ethylenediaminetetraacetic acid (EDTA)-dependent pseudothrombocytopenia.\",\"authors\":\"Yu Zhang, Bei Chen, Jiaoying Feng, Wen Yu, Wei Liang, Meifen Li, Guanghua Zhai, Meina Yan\",\"doi\":\"10.7717/peerj.19103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>EDTA-dependent pseudothrombocytopenia (EDTA-PTCP) is an <i>in vitro</i> phenomenon that may lead to expensive, time-consuming, and invasive diagnostic procedures as well as unnecessary patient treatment. The purpose of this study was to explore the effects of time, anticoagulant and detection channel on the platelet (PLT) count of EDTA-PTCP samples, and to suggest a better method for correcting spurious low PLT counts.</p><p><strong>Methods: </strong>In this study, 43 identified EDTA-PTCP samples were collected. The Sysmex XN-9100, Mindray BC-6900 and Mindray BC-5390 haematology analysers were used to test these EDTA-PTCP samples on the following detection channels at different time points: PLT count by impedance method (PLT-I), PLT count by optical method (PLT-O) and PLT count by fluorescent staining (PLT-F).</p><p><strong>Results: </strong>EDTA-PTCP was time-dependent and small PLT agglutination occurred in most of the corresponding citrate-treated samples. Our results further demonstrated that the detection channel significantly affected the PLT count of the EDTA-PTCP samples. The XN-9100 PLT-F channel exhibited a greater dissociative effect than the XN-9100 PLT-I and PLT-O channels. Moreover, blood samples processed in the PLT-O channel of the Mindray hematology analyzer showed the highest PLT count in EDTA-K2 tubes compared to the other detection channels.</p><p><strong>Conclusion: </strong>Our data showed that time, anticoagulant and detection channel significantly affected the PLT count in the EDTA-PTCP samples. For the EDTA-PTCP samples, the simplest retest method was to use the PLT-O channel of the Mindray automatic blood analyser within 30 min. In addition, changing the sodium citrate anticoagulant and using the XN-9100 PLT-F channel within 15 min were also suitable for correcting the spurious low PLT of the EDTA-PTCP samples.</p>\",\"PeriodicalId\":19799,\"journal\":{\"name\":\"PeerJ\",\"volume\":\"13 \",\"pages\":\"e19103\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11887562/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PeerJ\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.7717/peerj.19103\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PeerJ","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.7717/peerj.19103","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:edta依赖性假性血小板减少症(EDTA-PTCP)是一种体外现象,可能导致昂贵、耗时和侵入性的诊断程序以及不必要的患者治疗。本研究旨在探讨时间、抗凝剂和检测通道对EDTA-PTCP样品血小板(PLT)计数的影响,并提出一种更好的校正假低PLT计数的方法。方法:本研究收集了43份经鉴定的EDTA-PTCP样品。采用Sysmex XN-9100、迈瑞BC-6900和迈瑞BC-5390血液学分析仪分别在阻抗法(PLT- i)、光学法(PLT- o)和荧光染色法(PLT- f)检测通道上对EDTA-PTCP样品进行检测。结果:EDTA-PTCP具有时间依赖性,在大多数柠檬酸盐处理的样品中发生少量PLT凝集。我们的结果进一步表明,检测通道显著影响EDTA-PTCP样品的PLT计数。XN-9100 PLT-F通道比XN-9100 PLT-I和PLT-O通道表现出更大的解离效应。此外,在迈瑞血液学分析仪的PLT- o通道中处理的血液样本显示,与其他检测通道相比,EDTA-K2管中的PLT计数最高。结论:我们的数据显示,时间、抗凝剂和检测通道对EDTA-PTCP样本PLT计数有显著影响。对于EDTA-PTCP样品,最简单的复测方法是在30分钟内使用Mindray全自动血液分析仪的PLT- o通道。此外,在15分钟内更换柠檬酸钠抗凝剂和使用XN-9100 PLT- f通道也适用于纠正EDTA-PTCP样品PLT假低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of time, anticoagulant and detection channel on platelet count in ethylenediaminetetraacetic acid (EDTA)-dependent pseudothrombocytopenia.

Background: EDTA-dependent pseudothrombocytopenia (EDTA-PTCP) is an in vitro phenomenon that may lead to expensive, time-consuming, and invasive diagnostic procedures as well as unnecessary patient treatment. The purpose of this study was to explore the effects of time, anticoagulant and detection channel on the platelet (PLT) count of EDTA-PTCP samples, and to suggest a better method for correcting spurious low PLT counts.

Methods: In this study, 43 identified EDTA-PTCP samples were collected. The Sysmex XN-9100, Mindray BC-6900 and Mindray BC-5390 haematology analysers were used to test these EDTA-PTCP samples on the following detection channels at different time points: PLT count by impedance method (PLT-I), PLT count by optical method (PLT-O) and PLT count by fluorescent staining (PLT-F).

Results: EDTA-PTCP was time-dependent and small PLT agglutination occurred in most of the corresponding citrate-treated samples. Our results further demonstrated that the detection channel significantly affected the PLT count of the EDTA-PTCP samples. The XN-9100 PLT-F channel exhibited a greater dissociative effect than the XN-9100 PLT-I and PLT-O channels. Moreover, blood samples processed in the PLT-O channel of the Mindray hematology analyzer showed the highest PLT count in EDTA-K2 tubes compared to the other detection channels.

Conclusion: Our data showed that time, anticoagulant and detection channel significantly affected the PLT count in the EDTA-PTCP samples. For the EDTA-PTCP samples, the simplest retest method was to use the PLT-O channel of the Mindray automatic blood analyser within 30 min. In addition, changing the sodium citrate anticoagulant and using the XN-9100 PLT-F channel within 15 min were also suitable for correcting the spurious low PLT of the EDTA-PTCP samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
PeerJ
PeerJ MULTIDISCIPLINARY SCIENCES-
CiteScore
4.70
自引率
3.70%
发文量
1665
审稿时长
10 weeks
期刊介绍: PeerJ is an open access peer-reviewed scientific journal covering research in the biological and medical sciences. At PeerJ, authors take out a lifetime publication plan (for as little as $99) which allows them to publish articles in the journal for free, forever. PeerJ has 5 Nobel Prize Winners on the Board; they have won several industry and media awards; and they are widely recognized as being one of the most interesting recent developments in academic publishing.
期刊最新文献
Multi-scale analysis on eco-environmental quality patterns and associated driving factors: implications for the Henan section of the Yellow River Basin, China. Persistent loss of animal diversity on a rocky shore over nine decades and across multiple investigators. The influence of virtual reality technology on upper limb motor function in subacute stroke: a systematic review and meta-analysis. Effect of sodium-glucose cotransporter-2 inhibitors on fracture risk in patients with type 1 diabetes receiving insulin-based therapy: a meta-analysis. A new perspective on Icriomastax (Diptera: Tipulidae): phylogeny and description of five new species.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1