利用d -青霉胺碳点结合谷胱甘肽s -转移酶-金纳米团簇对叶酸进行比率荧光定量分析

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchimica Acta Pub Date : 2025-03-13 DOI:10.1007/s00604-025-07062-8
Mengyan Zhou, Zhihui Zhang, Qi Zheng, Mingdi Yu, Mengxu Si, Sirui Wu, Yanan Zhang, Shushu Ding, Ding-Yi Fu
{"title":"利用d -青霉胺碳点结合谷胱甘肽s -转移酶-金纳米团簇对叶酸进行比率荧光定量分析","authors":"Mengyan Zhou,&nbsp;Zhihui Zhang,&nbsp;Qi Zheng,&nbsp;Mingdi Yu,&nbsp;Mengxu Si,&nbsp;Sirui Wu,&nbsp;Yanan Zhang,&nbsp;Shushu Ding,&nbsp;Ding-Yi Fu","doi":"10.1007/s00604-025-07062-8","DOIUrl":null,"url":null,"abstract":"<div><p>A novel ratiometric fluorescent nanohybrid probe was constructed for sensitive and selective determination of folic acid (FA) based on blue D-penicillamine-based carbon dots (CDs) and red glutathione S-transferase-Au nanoclusters (GST-AuNCs). Upon the excitation of 380 nm, the obtained CDs-NCs possessed two distinct emission peaks at 465 and 665 nm. The fluorescence intensity at 465 nm was incrementally enhanced with the addition of FA attributed to the hydrogen bonds formation, while the fluorescence intensity at 665 nm was quenched caused by the electronic interaction and the inner filter effects. The fluorescence intensity ratio (<i>I</i><sub>465</sub><i>/I</i><sub>665</sub>) exhibited good linear correlation with FA concentrations in the range 10∼90 μM, and the limit of detection (LOD) was 0.63 μM. Notably, the corresponding fluorescent color changed from red to blue, which could be distinguished by naked eyes. On account of the excellent biocompatibility, the CDs-NCs were further successfully used for bioimaging and intracellular FA detection. Furthermore, the real sample analyses confirmed that the proposed nanoprobe could be expanded as a versatile platform for FA detection in practical applications.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 4","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ratiometric fluorescence quantification of folic acid utilizing D-penicillamine-based carbon dots in conjunction with glutathione S-transferase-Au nanoclusters\",\"authors\":\"Mengyan Zhou,&nbsp;Zhihui Zhang,&nbsp;Qi Zheng,&nbsp;Mingdi Yu,&nbsp;Mengxu Si,&nbsp;Sirui Wu,&nbsp;Yanan Zhang,&nbsp;Shushu Ding,&nbsp;Ding-Yi Fu\",\"doi\":\"10.1007/s00604-025-07062-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A novel ratiometric fluorescent nanohybrid probe was constructed for sensitive and selective determination of folic acid (FA) based on blue D-penicillamine-based carbon dots (CDs) and red glutathione S-transferase-Au nanoclusters (GST-AuNCs). Upon the excitation of 380 nm, the obtained CDs-NCs possessed two distinct emission peaks at 465 and 665 nm. The fluorescence intensity at 465 nm was incrementally enhanced with the addition of FA attributed to the hydrogen bonds formation, while the fluorescence intensity at 665 nm was quenched caused by the electronic interaction and the inner filter effects. The fluorescence intensity ratio (<i>I</i><sub>465</sub><i>/I</i><sub>665</sub>) exhibited good linear correlation with FA concentrations in the range 10∼90 μM, and the limit of detection (LOD) was 0.63 μM. Notably, the corresponding fluorescent color changed from red to blue, which could be distinguished by naked eyes. On account of the excellent biocompatibility, the CDs-NCs were further successfully used for bioimaging and intracellular FA detection. Furthermore, the real sample analyses confirmed that the proposed nanoprobe could be expanded as a versatile platform for FA detection in practical applications.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"192 4\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2025-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-025-07062-8\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-025-07062-8","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

基于蓝色d -青霉胺碳点(cd)和红色谷胱甘肽s -转移酶-金纳米簇(GST-AuNCs)构建了一种新型比例荧光纳米杂化探针,用于叶酸(FA)的灵敏和选择性检测。在380 nm激发下,得到的cds - nc在465和665 nm处有两个明显的发射峰。在465 nm处,由于氢键的形成,FA的加入使荧光强度逐渐增强,而在665 nm处,由于电子相互作用和内部过滤效应,荧光强度被淬灭。荧光强度比(I465/I665)与FA浓度在10 ~ 90 μM范围内呈良好的线性相关,检出限(LOD)为0.63 μM。值得注意的是,相应的荧光颜色由红色变为蓝色,可以用肉眼分辨。由于具有良好的生物相容性,cd - ncs进一步成功地用于生物成像和细胞内FA检测。此外,实际样品分析证实了所提出的纳米探针可以在实际应用中扩展为FA检测的多功能平台。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ratiometric fluorescence quantification of folic acid utilizing D-penicillamine-based carbon dots in conjunction with glutathione S-transferase-Au nanoclusters

A novel ratiometric fluorescent nanohybrid probe was constructed for sensitive and selective determination of folic acid (FA) based on blue D-penicillamine-based carbon dots (CDs) and red glutathione S-transferase-Au nanoclusters (GST-AuNCs). Upon the excitation of 380 nm, the obtained CDs-NCs possessed two distinct emission peaks at 465 and 665 nm. The fluorescence intensity at 465 nm was incrementally enhanced with the addition of FA attributed to the hydrogen bonds formation, while the fluorescence intensity at 665 nm was quenched caused by the electronic interaction and the inner filter effects. The fluorescence intensity ratio (I465/I665) exhibited good linear correlation with FA concentrations in the range 10∼90 μM, and the limit of detection (LOD) was 0.63 μM. Notably, the corresponding fluorescent color changed from red to blue, which could be distinguished by naked eyes. On account of the excellent biocompatibility, the CDs-NCs were further successfully used for bioimaging and intracellular FA detection. Furthermore, the real sample analyses confirmed that the proposed nanoprobe could be expanded as a versatile platform for FA detection in practical applications.

Graphical abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
Correction: A dual-color fluorescent probe based on CDs-loaded UiO-66-NH2 for simultaneous and highly selective detection of phosphate and superoxide anion radicals. A homogeneous fluorescence-electrochemiluminescence sensing platform based on EDTA-RuCOFs: ultrasensitive detection of Cu²⁺ via a chelation-quenching mechanism. A label-free dual-mode aptasensor for detecting zearalenone based on exonuclease I cascaded PtNWs/MXene nanozyme. High-performance amphoteric polymer coated lead-free halide perovskite composites: synthesis and application. A sensitive and cost-effective “turn-on” aptasensor for carcinoembryonic antigen using Ce-UiO-66 as an ultraefficient nanoquencher
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1