一种新型柔性两级制冷热泵调峰潜力的研究

IF 9.1 1区 工程技术 Q1 ENERGY & FUELS Renewable Energy Pub Date : 2025-06-15 Epub Date: 2025-03-15 DOI:10.1016/j.renene.2025.122882
Narges H. Mokarram , Zhichao Zhang , Zhibin Yu , Yiji Lu
{"title":"一种新型柔性两级制冷热泵调峰潜力的研究","authors":"Narges H. Mokarram ,&nbsp;Zhichao Zhang ,&nbsp;Zhibin Yu ,&nbsp;Yiji Lu","doi":"10.1016/j.renene.2025.122882","DOIUrl":null,"url":null,"abstract":"<div><div>This work introduces a new configuration of a flexible two-stage heat pump system (Co. 1) for cooling applications and compared it with the second configuration common in literature (Co. 2). This new system is investigated in comparison with other four systems under identical operating conditions: a baseline two-stage heat pump a baseline single-stage heat pump, and a flexible single-stage heat pump and a second configuration of the flexible two-stage heat pump. A control strategy is developed to regulate four operational modes — normal operation, charging, discharging, and standby, —depending on the cooling load, hour of the day, and status of the storage tanks. The weather data of London, UK, and Rome, Italy have been used to acquire the variable hourly cooling loads of a typical 4-story residential block via IESVE software. The results show that the flexible two-stage system and flexible single-stage systems achieve seasonal coefficients of performance (SCOP) 2.33 % and 2.55 % higher than the two baseline systems of two-stage and single-stage heat pumps, respectively. Furthermore, the heat pump demonstrates enhanced results in milder weather in London than in Rome. The newly proposed system in this study shows an overall higher SCOP than the other four compared heat pump systems.</div></div>","PeriodicalId":419,"journal":{"name":"Renewable Energy","volume":"246 ","pages":"Article 122882"},"PeriodicalIF":9.1000,"publicationDate":"2025-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation on the peak shaving potential of a new flexible two-stage heat pump for cooling\",\"authors\":\"Narges H. Mokarram ,&nbsp;Zhichao Zhang ,&nbsp;Zhibin Yu ,&nbsp;Yiji Lu\",\"doi\":\"10.1016/j.renene.2025.122882\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This work introduces a new configuration of a flexible two-stage heat pump system (Co. 1) for cooling applications and compared it with the second configuration common in literature (Co. 2). This new system is investigated in comparison with other four systems under identical operating conditions: a baseline two-stage heat pump a baseline single-stage heat pump, and a flexible single-stage heat pump and a second configuration of the flexible two-stage heat pump. A control strategy is developed to regulate four operational modes — normal operation, charging, discharging, and standby, —depending on the cooling load, hour of the day, and status of the storage tanks. The weather data of London, UK, and Rome, Italy have been used to acquire the variable hourly cooling loads of a typical 4-story residential block via IESVE software. The results show that the flexible two-stage system and flexible single-stage systems achieve seasonal coefficients of performance (SCOP) 2.33 % and 2.55 % higher than the two baseline systems of two-stage and single-stage heat pumps, respectively. Furthermore, the heat pump demonstrates enhanced results in milder weather in London than in Rome. The newly proposed system in this study shows an overall higher SCOP than the other four compared heat pump systems.</div></div>\",\"PeriodicalId\":419,\"journal\":{\"name\":\"Renewable Energy\",\"volume\":\"246 \",\"pages\":\"Article 122882\"},\"PeriodicalIF\":9.1000,\"publicationDate\":\"2025-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Renewable Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0960148125005440\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Renewable Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0960148125005440","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

本工作介绍了一种用于冷却应用的柔性两级热泵系统(Co. 1)的新配置,并将其与文献中常见的第二种配置(Co. 2)进行了比较。在相同的操作条件下,该新系统与其他四种系统进行了比较:基线两级热泵、基线单级热泵、柔性单级热泵和柔性两级热泵的第二种配置。根据冷负荷、一天中的小时数和储罐的状态,开发了一种控制策略来调节四种运行模式——正常运行、充电、放电和备用。利用英国伦敦和意大利罗马的天气数据,通过IESVE软件获得典型4层住宅楼每小时的变冷负荷。结果表明,柔性两级和单级热泵系统的季节性能系数(SCOP)分别比两级和单级热泵基准系统高2.33%和2.55%。此外,热泵在伦敦较温和的天气比在罗马表现出更好的效果。本研究中新提出的系统显示出比其他四种热泵系统总体更高的SCOP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation on the peak shaving potential of a new flexible two-stage heat pump for cooling
This work introduces a new configuration of a flexible two-stage heat pump system (Co. 1) for cooling applications and compared it with the second configuration common in literature (Co. 2). This new system is investigated in comparison with other four systems under identical operating conditions: a baseline two-stage heat pump a baseline single-stage heat pump, and a flexible single-stage heat pump and a second configuration of the flexible two-stage heat pump. A control strategy is developed to regulate four operational modes — normal operation, charging, discharging, and standby, —depending on the cooling load, hour of the day, and status of the storage tanks. The weather data of London, UK, and Rome, Italy have been used to acquire the variable hourly cooling loads of a typical 4-story residential block via IESVE software. The results show that the flexible two-stage system and flexible single-stage systems achieve seasonal coefficients of performance (SCOP) 2.33 % and 2.55 % higher than the two baseline systems of two-stage and single-stage heat pumps, respectively. Furthermore, the heat pump demonstrates enhanced results in milder weather in London than in Rome. The newly proposed system in this study shows an overall higher SCOP than the other four compared heat pump systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Renewable Energy
Renewable Energy 工程技术-能源与燃料
CiteScore
18.40
自引率
9.20%
发文量
1955
审稿时长
6.6 months
期刊介绍: Renewable Energy journal is dedicated to advancing knowledge and disseminating insights on various topics and technologies within renewable energy systems and components. Our mission is to support researchers, engineers, economists, manufacturers, NGOs, associations, and societies in staying updated on new developments in their respective fields and applying alternative energy solutions to current practices. As an international, multidisciplinary journal in renewable energy engineering and research, we strive to be a premier peer-reviewed platform and a trusted source of original research and reviews in the field of renewable energy. Join us in our endeavor to drive innovation and progress in sustainable energy solutions.
期刊最新文献
Structural and filling ratio optimization of flexible separate heat pipe developed for tracking PV/T systems Coordinated control approach for hydrogen vehicle gas supply and thermal management subsystems based on hybrid control framework Simultaneous hydrodeoxygenation-isomerization of biolipids to branched alkanes catalyzed by MoS2/SAPO-11 Barrier factors in residential photovoltaic system adoption: A conjoint experiment from an administrative burden perspective pH-driven shifts in acidogenic pathways modulate biohydrogen production: Experimental and in silico insights from continuous cultures of degenerated Clostridium acetobutylicum strain
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1