基于三维有限元法的II类修复体不同腔面边缘的比较分析

IF 2.1 4区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal for Numerical Methods in Biomedical Engineering Pub Date : 2025-04-16 DOI:10.1002/cnm.70041
Zuzanna Apel, Behzad Vafaeian, Joanna Zarzecka, Jenna Wuzinski, Derek B. Apel
{"title":"基于三维有限元法的II类修复体不同腔面边缘的比较分析","authors":"Zuzanna Apel,&nbsp;Behzad Vafaeian,&nbsp;Joanna Zarzecka,&nbsp;Jenna Wuzinski,&nbsp;Derek B. Apel","doi":"10.1002/cnm.70041","DOIUrl":null,"url":null,"abstract":"<p>The primary aim of these analyses was to evaluate the mechanical characteristics of the restored proximal surface of the lower first molar by comparing four different preparation designs: (a) slot preparation, (b) slot preparation with bevel, (c) slot preparation with bevel and rounded proximal box corners (RPBC), and (d) slot preparation with bevel, rounded proximal box corners, and gingival bevel (GB). The finite element method was utilized to assess various load scenarios applied to slot and bevelled restorations prepared using adhesive restorative materials. The numerical analysis revealed higher tensile stresses by up to 15 MPa when normal traction was applied at the interface between enamel and slot preparations than at the interface between enamel and bevelled preparations. However, the beveled restorations showed increased shear stresses in their thin beveled regions. The results imply a risk of separation for slot restorations. Conversely, incorporating a bevel (with or without RPBC and GB) significantly decreased normal stresses on the restoration edge and shifted it predominantly to compressive stresses. Thus, bevelled restorations may be less prone to debonding at their edges under occlusal loads. However, they may still be susceptible to shear debonding when locally loaded on their thin-beveled regions.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"41 4","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.70041","citationCount":"0","resultStr":"{\"title\":\"Comparative Analysis of Various Cavosurface Margins in Class II Restorations Using 3D Finite Element Method\",\"authors\":\"Zuzanna Apel,&nbsp;Behzad Vafaeian,&nbsp;Joanna Zarzecka,&nbsp;Jenna Wuzinski,&nbsp;Derek B. Apel\",\"doi\":\"10.1002/cnm.70041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The primary aim of these analyses was to evaluate the mechanical characteristics of the restored proximal surface of the lower first molar by comparing four different preparation designs: (a) slot preparation, (b) slot preparation with bevel, (c) slot preparation with bevel and rounded proximal box corners (RPBC), and (d) slot preparation with bevel, rounded proximal box corners, and gingival bevel (GB). The finite element method was utilized to assess various load scenarios applied to slot and bevelled restorations prepared using adhesive restorative materials. The numerical analysis revealed higher tensile stresses by up to 15 MPa when normal traction was applied at the interface between enamel and slot preparations than at the interface between enamel and bevelled preparations. However, the beveled restorations showed increased shear stresses in their thin beveled regions. The results imply a risk of separation for slot restorations. Conversely, incorporating a bevel (with or without RPBC and GB) significantly decreased normal stresses on the restoration edge and shifted it predominantly to compressive stresses. Thus, bevelled restorations may be less prone to debonding at their edges under occlusal loads. However, they may still be susceptible to shear debonding when locally loaded on their thin-beveled regions.</p>\",\"PeriodicalId\":50349,\"journal\":{\"name\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"volume\":\"41 4\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.70041\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70041\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70041","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

这些分析的主要目的是通过比较四种不同的准备设计来评估修复的下第一磨牙近端表面的力学特性:(a)槽准备,(b)带斜角的槽准备,(c)带斜角和圆形近端盒角的槽准备(RPBC),以及(d)带斜角、圆形近端盒角和牙龈斜角的槽准备(GB)。采用有限元方法对粘接修复材料制备的槽形和斜面修复体的各种载荷情况进行了评估。数值分析表明,在牙釉质与槽状牙釉质交界面处施加常规牵引时,牙釉质与坡面牙釉质交界面处的拉伸应力比在牙釉质与坡面牙釉质交界面处施加常规牵引时高15 MPa。然而,斜面修复体在其薄斜面区域显示出增加的剪应力。结果表明槽形修复存在分离的风险。相反,结合斜面(带或不带RPBC和GB)显着降低了恢复边缘的正常应力,并将其主要转移到压应力。因此,斜面修复体在咬合负荷下可能不太容易在其边缘脱落。然而,当局部加载在薄斜面区域时,它们可能仍然容易发生剪切脱粘。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative Analysis of Various Cavosurface Margins in Class II Restorations Using 3D Finite Element Method

The primary aim of these analyses was to evaluate the mechanical characteristics of the restored proximal surface of the lower first molar by comparing four different preparation designs: (a) slot preparation, (b) slot preparation with bevel, (c) slot preparation with bevel and rounded proximal box corners (RPBC), and (d) slot preparation with bevel, rounded proximal box corners, and gingival bevel (GB). The finite element method was utilized to assess various load scenarios applied to slot and bevelled restorations prepared using adhesive restorative materials. The numerical analysis revealed higher tensile stresses by up to 15 MPa when normal traction was applied at the interface between enamel and slot preparations than at the interface between enamel and bevelled preparations. However, the beveled restorations showed increased shear stresses in their thin beveled regions. The results imply a risk of separation for slot restorations. Conversely, incorporating a bevel (with or without RPBC and GB) significantly decreased normal stresses on the restoration edge and shifted it predominantly to compressive stresses. Thus, bevelled restorations may be less prone to debonding at their edges under occlusal loads. However, they may still be susceptible to shear debonding when locally loaded on their thin-beveled regions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
期刊最新文献
Direct Numerical Simulations of Inhalation in a 23-Generation Lung Model Modeling Perforator Occlusion After Flow Diversion A Closed-Loop Cardiovascular Model of the Supine-To-Stand Manoeuvre: Implications for Falls Biofidelic Simulations of the Ross Procedure: Arterial Growth and Remodeling in an Anatomical Context A Comprehensive Numerical Simulation on the Safety and Efficacy of Circular-Versus Trapezoidal-Shaped Intravascular Drug-Eluting Stents
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1