M Akisada, K Hyodo, M Ando, A Maruhashi, K Konishi, F Toyofuku, K Nishimura, S Hasegawa, A Suwa, E Takenaka
{"title":"光子工厂同步辐射无创冠状动脉造影术:实验研究。","authors":"M Akisada, K Hyodo, M Ando, A Maruhashi, K Konishi, F Toyofuku, K Nishimura, S Hasegawa, A Suwa, E Takenaka","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Synchrotron radiation available at the Photon Factory, National Laboratory for High Energy Physics, provides a new X-ray source which is highly suitable for K-edge subtraction. This is due to its high intensity, its parallelism and its monochromaticity, available in a monochromator system. Experiments were performed using wiggler synchrotron radiation. Since the beam size is relatively-small for in-vivo imaging, a phantom coupled with a detector was moved horizontally using a scanning table. K-edge subtraction was successfully applied both to the coronary artery phantom filled with barium sulphate, and to rat angiography using iodine contrast material. The potential use and value of energy subtraction was successfully demonstrated.</p>","PeriodicalId":77734,"journal":{"name":"Journal of cardiography","volume":"16 3","pages":"527-34"},"PeriodicalIF":0.0000,"publicationDate":"1986-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synchrotron radiation at the Photon Factory for non-invasive coronary angiography: experimental studies.\",\"authors\":\"M Akisada, K Hyodo, M Ando, A Maruhashi, K Konishi, F Toyofuku, K Nishimura, S Hasegawa, A Suwa, E Takenaka\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Synchrotron radiation available at the Photon Factory, National Laboratory for High Energy Physics, provides a new X-ray source which is highly suitable for K-edge subtraction. This is due to its high intensity, its parallelism and its monochromaticity, available in a monochromator system. Experiments were performed using wiggler synchrotron radiation. Since the beam size is relatively-small for in-vivo imaging, a phantom coupled with a detector was moved horizontally using a scanning table. K-edge subtraction was successfully applied both to the coronary artery phantom filled with barium sulphate, and to rat angiography using iodine contrast material. The potential use and value of energy subtraction was successfully demonstrated.</p>\",\"PeriodicalId\":77734,\"journal\":{\"name\":\"Journal of cardiography\",\"volume\":\"16 3\",\"pages\":\"527-34\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cardiography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiography","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Synchrotron radiation at the Photon Factory for non-invasive coronary angiography: experimental studies.
Synchrotron radiation available at the Photon Factory, National Laboratory for High Energy Physics, provides a new X-ray source which is highly suitable for K-edge subtraction. This is due to its high intensity, its parallelism and its monochromaticity, available in a monochromator system. Experiments were performed using wiggler synchrotron radiation. Since the beam size is relatively-small for in-vivo imaging, a phantom coupled with a detector was moved horizontally using a scanning table. K-edge subtraction was successfully applied both to the coronary artery phantom filled with barium sulphate, and to rat angiography using iodine contrast material. The potential use and value of energy subtraction was successfully demonstrated.