新墨西哥州阿尔伯克基室内住宅二氧化氮浓度。

M C Marbury, D P Harlos, J M Samet, J D Spengler
{"title":"新墨西哥州阿尔伯克基室内住宅二氧化氮浓度。","authors":"M C Marbury, D P Harlos, J M Samet, J D Spengler","doi":"10.1080/08940630.1988.10466388","DOIUrl":null,"url":null,"abstract":"In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to...","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"38 4","pages":"392-8"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1988.10466388","citationCount":"29","resultStr":"{\"title\":\"Indoor residential NO2 concentrations in Albuquerque, New Mexico.\",\"authors\":\"M C Marbury, D P Harlos, J M Samet, J D Spengler\",\"doi\":\"10.1080/08940630.1988.10466388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to...\",\"PeriodicalId\":77731,\"journal\":{\"name\":\"JAPCA\",\"volume\":\"38 4\",\"pages\":\"392-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/08940630.1988.10466388\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAPCA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08940630.1988.10466388\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1988.10466388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Indoor residential NO2 concentrations in Albuquerque, New Mexico.
In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The superfund remedial action decision process: a review of fifty records of decision. Indoor ozone exposures. Particulate and nicotine sampling in public facilities and offices. Air levels and mutagenicity of PM-10 in an indoor ice arena. Summary of the 1989 EPA/A&WMA International symposium: measurement of toxic and related air pollutants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1