氧债的“厌氧”成分与温盖特试验的比较。

B R Goslin, T E Graham
{"title":"氧债的“厌氧”成分与温盖特试验的比较。","authors":"B R Goslin,&nbsp;T E Graham","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study compared measurements which were considered traditionally to reflect alactacid and lactacid components of anaerobic metabolism. Subjects (men (N = 9) and women (N = 5)) on one occasion performed an exhaustive cycle ergometer ride at VO2 max and had peak lactate and O2 debt (fast and slow components) determined. On a second occasion, they performed a Wingate test. All data were normalized for body weight. Very few correlations were found between O2 debt or peak lactate and the peak power, mean power and power decrease of the Wingate test. In particular, both peak lactate and the fast O2 debt component had low, nonsignificant correlations with either peak or mean power. The study failed to support the traditional assumptions that both tests are quantifying the same anaerobic energy systems.</p>","PeriodicalId":75669,"journal":{"name":"Canadian journal of applied sport sciences. Journal canadien des sciences appliquees au sport","volume":"10 3","pages":"134-40"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of 'anaerobic' components of O2 debt and the Wingate test.\",\"authors\":\"B R Goslin,&nbsp;T E Graham\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study compared measurements which were considered traditionally to reflect alactacid and lactacid components of anaerobic metabolism. Subjects (men (N = 9) and women (N = 5)) on one occasion performed an exhaustive cycle ergometer ride at VO2 max and had peak lactate and O2 debt (fast and slow components) determined. On a second occasion, they performed a Wingate test. All data were normalized for body weight. Very few correlations were found between O2 debt or peak lactate and the peak power, mean power and power decrease of the Wingate test. In particular, both peak lactate and the fast O2 debt component had low, nonsignificant correlations with either peak or mean power. The study failed to support the traditional assumptions that both tests are quantifying the same anaerobic energy systems.</p>\",\"PeriodicalId\":75669,\"journal\":{\"name\":\"Canadian journal of applied sport sciences. Journal canadien des sciences appliquees au sport\",\"volume\":\"10 3\",\"pages\":\"134-40\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian journal of applied sport sciences. Journal canadien des sciences appliquees au sport\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian journal of applied sport sciences. Journal canadien des sciences appliquees au sport","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项研究比较了传统上被认为反映厌氧代谢的半乳酸和乳酸成分的测量。受试者(男性(N = 9)和女性(N = 5))有一次在最大摄氧量下进行了一次穷尽式的骑行,并测定了峰值乳酸和氧债(快速和慢速成分)。第二次,他们进行了温盖特测试。所有数据均按体重归一化。O2债务或乳酸峰值与Wingate检验的峰值功率、平均功率和功率下降之间的相关性很小。特别是,乳酸峰值和快氧债务成分与峰值或平均功率的相关性都很低,不显著。该研究未能支持传统的假设,即两种测试都是量化相同的厌氧能量系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A comparison of 'anaerobic' components of O2 debt and the Wingate test.

This study compared measurements which were considered traditionally to reflect alactacid and lactacid components of anaerobic metabolism. Subjects (men (N = 9) and women (N = 5)) on one occasion performed an exhaustive cycle ergometer ride at VO2 max and had peak lactate and O2 debt (fast and slow components) determined. On a second occasion, they performed a Wingate test. All data were normalized for body weight. Very few correlations were found between O2 debt or peak lactate and the peak power, mean power and power decrease of the Wingate test. In particular, both peak lactate and the fast O2 debt component had low, nonsignificant correlations with either peak or mean power. The study failed to support the traditional assumptions that both tests are quantifying the same anaerobic energy systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
STEROACUITY IN MONOCULARLY INDUCED ASTIMATISM IN EMMETROPES AND AMMETROPES: A COMPARATIVE CROSSSECTIONAL STUDY EPIDEMIOLOGY AND PHARMACOTHERAPY OF ROTAVIRUS AND IMPACT OF VACCINATION TO PREVENTION ITS MORTALITY PREDICTORS OF LATE PRESENTATION OF DIABETIC RETINOPATHY: A MISSED OPPORTUNITY FOR HEALTH SYSTEMS IN PAKISTAN EFFECTIVENESS OF TRADITIONAL TEACHING AUGMENTED WITH INTERACTIVE SESSIONS AS A NEW APPROACH IN BIOCHEMISTRY TEACHING TRANSMISSION OF SARS-CoV-2 CAN BE CONTROLLED BY ADOPTING STANDARD SAFETY PROCEDURES AND USING PERSONAL PROTECTIVE EQUIPMENT (PPE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1