{"title":"修饰Bi2O3NPs-AgNPs-ErGO作为首个电化学纳米传感器用于药物剂型和人血清样品中奈拉宾的灵敏测定","authors":"Md. Zahirul Kabir , Cem Erkmen , Sevinc Kurbanoglu , Gözde Aydogdu Tig , Bengi Uslu","doi":"10.1016/j.jelechem.2023.117651","DOIUrl":null,"url":null,"abstract":"<div><p>In view of the unquestionable necessity for rapid and accurate analysis of drug molecules to monitor patient overdose, numerous nanosensor-based technologies have been developed in addition to quality control of pharmaceutical manufacture and drug administration. In this regard, sensitive detection of a potent anticancer agent, nelarabine (NEL) was examined at the bare and modified glassy carbon electrode (GCE) with the help of differential pulse (DP) and cyclic voltammetry (CV) techniques. A unique and highly effective nanosensor was developed using a combination of bismuth (III) oxide nanoparticles (Bi<sub>2</sub>O<sub>3</sub>NPs), silver nanoparticles (AgNPs), and electrochemically reduced graphene oxide (ErGO) onto the GCE surface. The modified Bi<sub>2</sub>O<sub>3</sub>NPs-AgNPs-ErGO/GCE was characterized by scanning electron microscopy (SEM), CV, and electrochemical impedance spectroscopy (EIS) investigations. Influences of various parameters <em>viz.</em>, loading of Bi<sub>2</sub>O<sub>3</sub>NPs, AgNPs, and GO on the modified GCE, electrolyte pH (PBS 7.0), accumulation potential (–0.2 V), and time (60 s), and scan rate (50 mV s<sup>−1</sup>) were optimized for NEL response. An enhancement in the current responses toward the oxidation of NEL was observed with the Bi<sub>2</sub>O<sub>3</sub>NPs-AgNPs-ErGO/GCE compared to that noticed with bare GCE. The modified GCE affirmed high sensitivity, low limit of detection (LOD), excellent reproducibility, repeatability, and storage stability that clearly indicated the effective accuracy of the developed nanosensor. The linear behavior in the concentration range was found to be 0.02–1.0 µM, with LOD values of 0.003 nM in PBS 7.0 and 0.065 nM in serum samples. The electrochemical mechanism of NEL at the bare and modified GCEs were revealed as diffusion-controlled and adsorption-controlled mechanism processes, respectively. The linear calibration curves at both the bare and modified GCEs were noticed for increasing NEL concentrations, as constructed from the DPV measurements. Applications of the Bi<sub>2</sub>O<sub>3</sub>NPs-AgNPs-ErGO/GCE for NEL detection in pharmaceutical dosage form and human serum sample showed well-accepted recovery results of 98–99 %. The effect of interfering agents was checked on the selectivity of the developed method, and the modified electrode was found to be selective toward NEL in the presence of these interfering agents.</p></div>","PeriodicalId":50545,"journal":{"name":"Journal of Electroanalytical Chemistry","volume":"944 ","pages":"Article 117651"},"PeriodicalIF":4.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Decoration of Bi2O3NPs-AgNPs-ErGO as a first electrochemical nanosensor for sensitive determination of nelarabine in pharmaceutical dosage form and human serum samples\",\"authors\":\"Md. Zahirul Kabir , Cem Erkmen , Sevinc Kurbanoglu , Gözde Aydogdu Tig , Bengi Uslu\",\"doi\":\"10.1016/j.jelechem.2023.117651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In view of the unquestionable necessity for rapid and accurate analysis of drug molecules to monitor patient overdose, numerous nanosensor-based technologies have been developed in addition to quality control of pharmaceutical manufacture and drug administration. In this regard, sensitive detection of a potent anticancer agent, nelarabine (NEL) was examined at the bare and modified glassy carbon electrode (GCE) with the help of differential pulse (DP) and cyclic voltammetry (CV) techniques. A unique and highly effective nanosensor was developed using a combination of bismuth (III) oxide nanoparticles (Bi<sub>2</sub>O<sub>3</sub>NPs), silver nanoparticles (AgNPs), and electrochemically reduced graphene oxide (ErGO) onto the GCE surface. The modified Bi<sub>2</sub>O<sub>3</sub>NPs-AgNPs-ErGO/GCE was characterized by scanning electron microscopy (SEM), CV, and electrochemical impedance spectroscopy (EIS) investigations. Influences of various parameters <em>viz.</em>, loading of Bi<sub>2</sub>O<sub>3</sub>NPs, AgNPs, and GO on the modified GCE, electrolyte pH (PBS 7.0), accumulation potential (–0.2 V), and time (60 s), and scan rate (50 mV s<sup>−1</sup>) were optimized for NEL response. An enhancement in the current responses toward the oxidation of NEL was observed with the Bi<sub>2</sub>O<sub>3</sub>NPs-AgNPs-ErGO/GCE compared to that noticed with bare GCE. The modified GCE affirmed high sensitivity, low limit of detection (LOD), excellent reproducibility, repeatability, and storage stability that clearly indicated the effective accuracy of the developed nanosensor. The linear behavior in the concentration range was found to be 0.02–1.0 µM, with LOD values of 0.003 nM in PBS 7.0 and 0.065 nM in serum samples. The electrochemical mechanism of NEL at the bare and modified GCEs were revealed as diffusion-controlled and adsorption-controlled mechanism processes, respectively. The linear calibration curves at both the bare and modified GCEs were noticed for increasing NEL concentrations, as constructed from the DPV measurements. Applications of the Bi<sub>2</sub>O<sub>3</sub>NPs-AgNPs-ErGO/GCE for NEL detection in pharmaceutical dosage form and human serum sample showed well-accepted recovery results of 98–99 %. The effect of interfering agents was checked on the selectivity of the developed method, and the modified electrode was found to be selective toward NEL in the presence of these interfering agents.</p></div>\",\"PeriodicalId\":50545,\"journal\":{\"name\":\"Journal of Electroanalytical Chemistry\",\"volume\":\"944 \",\"pages\":\"Article 117651\"},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electroanalytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1572665723005118\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Chemical Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electroanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1572665723005118","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Chemical Engineering","Score":null,"Total":0}
Decoration of Bi2O3NPs-AgNPs-ErGO as a first electrochemical nanosensor for sensitive determination of nelarabine in pharmaceutical dosage form and human serum samples
In view of the unquestionable necessity for rapid and accurate analysis of drug molecules to monitor patient overdose, numerous nanosensor-based technologies have been developed in addition to quality control of pharmaceutical manufacture and drug administration. In this regard, sensitive detection of a potent anticancer agent, nelarabine (NEL) was examined at the bare and modified glassy carbon electrode (GCE) with the help of differential pulse (DP) and cyclic voltammetry (CV) techniques. A unique and highly effective nanosensor was developed using a combination of bismuth (III) oxide nanoparticles (Bi2O3NPs), silver nanoparticles (AgNPs), and electrochemically reduced graphene oxide (ErGO) onto the GCE surface. The modified Bi2O3NPs-AgNPs-ErGO/GCE was characterized by scanning electron microscopy (SEM), CV, and electrochemical impedance spectroscopy (EIS) investigations. Influences of various parameters viz., loading of Bi2O3NPs, AgNPs, and GO on the modified GCE, electrolyte pH (PBS 7.0), accumulation potential (–0.2 V), and time (60 s), and scan rate (50 mV s−1) were optimized for NEL response. An enhancement in the current responses toward the oxidation of NEL was observed with the Bi2O3NPs-AgNPs-ErGO/GCE compared to that noticed with bare GCE. The modified GCE affirmed high sensitivity, low limit of detection (LOD), excellent reproducibility, repeatability, and storage stability that clearly indicated the effective accuracy of the developed nanosensor. The linear behavior in the concentration range was found to be 0.02–1.0 µM, with LOD values of 0.003 nM in PBS 7.0 and 0.065 nM in serum samples. The electrochemical mechanism of NEL at the bare and modified GCEs were revealed as diffusion-controlled and adsorption-controlled mechanism processes, respectively. The linear calibration curves at both the bare and modified GCEs were noticed for increasing NEL concentrations, as constructed from the DPV measurements. Applications of the Bi2O3NPs-AgNPs-ErGO/GCE for NEL detection in pharmaceutical dosage form and human serum sample showed well-accepted recovery results of 98–99 %. The effect of interfering agents was checked on the selectivity of the developed method, and the modified electrode was found to be selective toward NEL in the presence of these interfering agents.
期刊介绍:
The Journal of Electroanalytical Chemistry is the foremost international journal devoted to the interdisciplinary subject of electrochemistry in all its aspects, theoretical as well as applied.
Electrochemistry is a wide ranging area that is in a state of continuous evolution. Rather than compiling a long list of topics covered by the Journal, the editors would like to draw particular attention to the key issues of novelty, topicality and quality. Papers should present new and interesting electrochemical science in a way that is accessible to the reader. The presentation and discussion should be at a level that is consistent with the international status of the Journal. Reports describing the application of well-established techniques to problems that are essentially technical will not be accepted. Similarly, papers that report observations but fail to provide adequate interpretation will be rejected by the Editors. Papers dealing with technical electrochemistry should be submitted to other specialist journals unless the authors can show that their work provides substantially new insights into electrochemical processes.