小儿胸腔镜下超声探头检测肺实质内恶性肿瘤的前瞻性评价。

M B Smith, T E Lobe, K P Schropp, D A Rogers
{"title":"小儿胸腔镜下超声探头检测肺实质内恶性肿瘤的前瞻性评价。","authors":"M B Smith,&nbsp;T E Lobe,&nbsp;K P Schropp,&nbsp;D A Rogers","doi":"10.1089/lps.1996.6.233","DOIUrl":null,"url":null,"abstract":"<p><p>Thoracoscopy has been proposed as the procedure of choice for the evaluation of focal, suspected malignant pulmonary lesions in children. One drawback with this approach, however, is the concern that intraparenchymal lesions may go undetected. We prospectively evaluated the ability of an endoscopic ultrasonic probe to detect intraparenchymal nodules. The handheld probe contains a piezoelectric ultrasound emitter and receiver that operates at 7.5 MHz. The axial resolution of the probe is 1.1 cm. Two different probe tips were used. One is a forward viewing tip and the other is angled at 45 degrees relative to the axis of the probe shaft. Both probes image 90 degrees sectors. Twelve thoracoscopies on nine patients were performed using the ultrasound probe. Of seven patients with confirmed metastatic disease, six had thoracoscopy converted to open thoracotomy to assure that no lesion had been missed. The probe was able to accurately assess surrounding bronchovascular structures and the presence and location of previously placed surgical clips. Although deep structures were readily visualized with the probe, lesions within 1.5 cm of the surface of the lung were poorly visualized. No complications occurred. This ultrasound system allows for the distinction of dense lesions from the surrounding pulmonary parenchyma except for those lying near the surface of the lung, which are usually easy to see directly. Furthermore, the images define the broncho vascular structures adjacent to the lesion. This device may enhance thoracoscopy by facilitating the detection of, and ability to resect, pulmonary intraparenchymal lesions.</p>","PeriodicalId":77211,"journal":{"name":"Journal of laparoendoscopic surgery","volume":"6 4","pages":"233-7"},"PeriodicalIF":0.0000,"publicationDate":"1996-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/lps.1996.6.233","citationCount":"9","resultStr":"{\"title\":\"A prospective evaluation of an endoscopic ultrasonic probe to detect intraparenchymal malignancy at pediatric thoracoscopy.\",\"authors\":\"M B Smith,&nbsp;T E Lobe,&nbsp;K P Schropp,&nbsp;D A Rogers\",\"doi\":\"10.1089/lps.1996.6.233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Thoracoscopy has been proposed as the procedure of choice for the evaluation of focal, suspected malignant pulmonary lesions in children. One drawback with this approach, however, is the concern that intraparenchymal lesions may go undetected. We prospectively evaluated the ability of an endoscopic ultrasonic probe to detect intraparenchymal nodules. The handheld probe contains a piezoelectric ultrasound emitter and receiver that operates at 7.5 MHz. The axial resolution of the probe is 1.1 cm. Two different probe tips were used. One is a forward viewing tip and the other is angled at 45 degrees relative to the axis of the probe shaft. Both probes image 90 degrees sectors. Twelve thoracoscopies on nine patients were performed using the ultrasound probe. Of seven patients with confirmed metastatic disease, six had thoracoscopy converted to open thoracotomy to assure that no lesion had been missed. The probe was able to accurately assess surrounding bronchovascular structures and the presence and location of previously placed surgical clips. Although deep structures were readily visualized with the probe, lesions within 1.5 cm of the surface of the lung were poorly visualized. No complications occurred. This ultrasound system allows for the distinction of dense lesions from the surrounding pulmonary parenchyma except for those lying near the surface of the lung, which are usually easy to see directly. Furthermore, the images define the broncho vascular structures adjacent to the lesion. This device may enhance thoracoscopy by facilitating the detection of, and ability to resect, pulmonary intraparenchymal lesions.</p>\",\"PeriodicalId\":77211,\"journal\":{\"name\":\"Journal of laparoendoscopic surgery\",\"volume\":\"6 4\",\"pages\":\"233-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1089/lps.1996.6.233\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of laparoendoscopic surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/lps.1996.6.233\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of laparoendoscopic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/lps.1996.6.233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

胸腔镜已被建议作为评估局灶性、可疑的儿童恶性肺病变的首选程序。然而,这种方法的一个缺点是担心肺实质内病变可能未被发现。我们前瞻性地评估了内窥镜超声探头检测实质内结节的能力。手持式探头包含一个压电超声发射器和接收器,工作频率为7.5兆赫兹。探头轴向分辨率为1.1 cm。使用了两种不同的探针尖端。一个是前视尖端,另一个相对于探头轴的轴线成45度角。两个探头都能成像90度扇形。采用超声探头对9例患者进行了12次胸腔镜检查。在确诊为转移性疾病的7例患者中,有6例将胸腔镜转为开胸手术,以确保没有遗漏任何病变。该探针能够准确评估周围支气管血管结构以及先前放置的手术夹的存在和位置。虽然探针可以很容易地显示深部结构,但距离肺表面1.5 cm以内的病变却很难显示。无并发症发生。该超声系统可以区分周围肺实质的致密病变,除了那些靠近肺表面的病变,这些病变通常很容易直接看到。此外,图像明确了病变附近的支气管血管结构。该装置可以通过促进肺实质内病变的检测和切除能力来增强胸腔镜检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A prospective evaluation of an endoscopic ultrasonic probe to detect intraparenchymal malignancy at pediatric thoracoscopy.

Thoracoscopy has been proposed as the procedure of choice for the evaluation of focal, suspected malignant pulmonary lesions in children. One drawback with this approach, however, is the concern that intraparenchymal lesions may go undetected. We prospectively evaluated the ability of an endoscopic ultrasonic probe to detect intraparenchymal nodules. The handheld probe contains a piezoelectric ultrasound emitter and receiver that operates at 7.5 MHz. The axial resolution of the probe is 1.1 cm. Two different probe tips were used. One is a forward viewing tip and the other is angled at 45 degrees relative to the axis of the probe shaft. Both probes image 90 degrees sectors. Twelve thoracoscopies on nine patients were performed using the ultrasound probe. Of seven patients with confirmed metastatic disease, six had thoracoscopy converted to open thoracotomy to assure that no lesion had been missed. The probe was able to accurately assess surrounding bronchovascular structures and the presence and location of previously placed surgical clips. Although deep structures were readily visualized with the probe, lesions within 1.5 cm of the surface of the lung were poorly visualized. No complications occurred. This ultrasound system allows for the distinction of dense lesions from the surrounding pulmonary parenchyma except for those lying near the surface of the lung, which are usually easy to see directly. Furthermore, the images define the broncho vascular structures adjacent to the lesion. This device may enhance thoracoscopy by facilitating the detection of, and ability to resect, pulmonary intraparenchymal lesions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Laparoscopic Appendectomy The efficacy of epidural anesthesia for endoscopic preperitoneal herniorrhaphy: a prospective study. Results of a prospective multicenter trial evaluating the ePTFE peritoneal onlay laparoscopic inguinal hernioplasty. Laparoscopic treatment of nonparasitic cysts of spleen and liver. Morbidity and mortality of laparoscopic cholecystectomy in an institutional setup.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1