Deborah C. Rice
{"title":"猴子终生铅暴露对纯音检测的影响","authors":"Deborah C. Rice","doi":"10.1006/faat.1996.2268","DOIUrl":null,"url":null,"abstract":"<div><p>Increased detection thresholds for pure tones were observed in a large cohort of children exposed to lead environmentally while smaller studies in lead-exposed workers have reported conflicting results on assessments of auditory function. Pure tone detection thresholds were determined in a group of monkeys (<em>Macaca fascicularis</em>) dosed with 2 mg/kg/day of lead from birth through testing at 13 years of age. Blood lead concentrations were stable at about 30 μg/dl until monkeys were 10–11 years of age, at which time they increased to between 50 and 170 μg/dl. Five age- and rearing-matched monkeys served as controls. Detection thresholds were determined at six frequencies between 0.125 and 31.5 kHz. Earphones were fit over both ears, and thresholds were determined for each ear separately. The monkey signaled detection of the tone by breaking contact with a stainless steel bar. Three lead-exposed monkeys exhibited normal pure tone detection functions. Three monkeys had thresholds outside of the control range at some frequencies; there was a tendency for higher frequencies to be differentially more affected. These findings are consistent with reports of elevated pure tone thresholds in humans exposed to lead developmentally, although the effect is smaller than might have been predicted given the concurrent blood lead concentrations of these monkeys.</p></div>","PeriodicalId":100557,"journal":{"name":"Fundamental and Applied Toxicology","volume":"36 2","pages":"Pages 112-118"},"PeriodicalIF":0.0000,"publicationDate":"1997-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1006/faat.1996.2268","citationCount":"0","resultStr":"{\"title\":\"Effects of Lifetime Lead Exposure in Monkeys on Detection of Pure Tones\",\"authors\":\"Deborah C. Rice\",\"doi\":\"10.1006/faat.1996.2268\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Increased detection thresholds for pure tones were observed in a large cohort of children exposed to lead environmentally while smaller studies in lead-exposed workers have reported conflicting results on assessments of auditory function. Pure tone detection thresholds were determined in a group of monkeys (<em>Macaca fascicularis</em>) dosed with 2 mg/kg/day of lead from birth through testing at 13 years of age. Blood lead concentrations were stable at about 30 μg/dl until monkeys were 10–11 years of age, at which time they increased to between 50 and 170 μg/dl. Five age- and rearing-matched monkeys served as controls. Detection thresholds were determined at six frequencies between 0.125 and 31.5 kHz. Earphones were fit over both ears, and thresholds were determined for each ear separately. The monkey signaled detection of the tone by breaking contact with a stainless steel bar. Three lead-exposed monkeys exhibited normal pure tone detection functions. Three monkeys had thresholds outside of the control range at some frequencies; there was a tendency for higher frequencies to be differentially more affected. These findings are consistent with reports of elevated pure tone thresholds in humans exposed to lead developmentally, although the effect is smaller than might have been predicted given the concurrent blood lead concentrations of these monkeys.</p></div>\",\"PeriodicalId\":100557,\"journal\":{\"name\":\"Fundamental and Applied Toxicology\",\"volume\":\"36 2\",\"pages\":\"Pages 112-118\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1006/faat.1996.2268\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fundamental and Applied Toxicology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S027205909692268X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fundamental and Applied Toxicology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S027205909692268X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在大量接触铅环境的儿童中观察到纯音的检测阈值增加,而在接触铅的工人中进行的小型研究报告了听觉功能评估的相互矛盾的结果。对一组猕猴(Macaca fascularis)进行纯音检测阈值的测定,这些猕猴从出生开始每天摄入2mg /kg的铅,并在13岁时进行检测。在猴子10-11岁之前,血铅浓度稳定在30 μg/dl左右,然后上升到50 - 170 μg/dl。5只年龄和教养相匹配的猴子作为对照。检测阈值确定在0.125和31.5 kHz之间的六个频率。两只耳朵都戴上耳机,并分别为每只耳朵确定阈值。猴子通过断开与一根不锈钢棒的接触来发出检测到音调的信号。三只铅暴露的猴子表现出正常的纯音检测功能。三只猴子的阈值在某些频率上超出了控制范围;有一种趋势是,频率越高,受到的影响越大。这些发现与有关在发育过程中暴露于铅的人类纯音阈值升高的报告一致,尽管考虑到这些猴子的同期血铅浓度,其影响可能比预测的要小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of Lifetime Lead Exposure in Monkeys on Detection of Pure Tones

Increased detection thresholds for pure tones were observed in a large cohort of children exposed to lead environmentally while smaller studies in lead-exposed workers have reported conflicting results on assessments of auditory function. Pure tone detection thresholds were determined in a group of monkeys (Macaca fascicularis) dosed with 2 mg/kg/day of lead from birth through testing at 13 years of age. Blood lead concentrations were stable at about 30 μg/dl until monkeys were 10–11 years of age, at which time they increased to between 50 and 170 μg/dl. Five age- and rearing-matched monkeys served as controls. Detection thresholds were determined at six frequencies between 0.125 and 31.5 kHz. Earphones were fit over both ears, and thresholds were determined for each ear separately. The monkey signaled detection of the tone by breaking contact with a stainless steel bar. Three lead-exposed monkeys exhibited normal pure tone detection functions. Three monkeys had thresholds outside of the control range at some frequencies; there was a tendency for higher frequencies to be differentially more affected. These findings are consistent with reports of elevated pure tone thresholds in humans exposed to lead developmentally, although the effect is smaller than might have been predicted given the concurrent blood lead concentrations of these monkeys.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rat Olfactory Mucosa Displays a High Activity in Metabolizing Methyltert-butyl Ether and Other Gasoline Ethers Assessment of Respiratory Hypersensitivity in Guinea Pigs Sensitized to Toluene Diisocyanate: Improvements on Analysis of Respiratory Response Intratracheal Inhalation vs Intratracheal Instillation: Differences in Particle Effects Differences in Caffeine 3-Demethylation Activity among Inbred Mouse Strains: A Comparison of HepaticCyp1a2Gene Expression between Two Inbred Strains Ketoconazole Impairs Early Pregnancy and the Decidual Cell Response via Alterations in Ovarian Function
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1