人抗小鼠抗体对促甲状腺素体外分析的影响:6种促甲状腺素IRMA试剂盒的比较。

P Mikosch, H J Gallowitsch, E Kresnik, M Molnar, I Gomez, P Lind
{"title":"人抗小鼠抗体对促甲状腺素体外分析的影响:6种促甲状腺素IRMA试剂盒的比较。","authors":"P Mikosch,&nbsp;H J Gallowitsch,&nbsp;E Kresnik,&nbsp;M Molnar,&nbsp;I Gomez,&nbsp;P Lind","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the study was to evaluate the influence of human anti-mouse antibodies on the measurement of thyrotropin.</p><p><strong>Investigations: </strong>Samples from 11 patients with measureable human anti-mouse antibody titres (19 micrograms/l-3880 micrograms/l) after radioimmuno-scintigraphy were analysed with 6 different thyrotropin immuno-radiometric assay kits (IRMA). Each sample was analysed in the routine way (sample influenced by human anti-mouse antibodies), as well as after incubation with murine immunoglobulin to precipitate human anti-mouse antibodies (samples not influenced by human anti-mouse antibodies).</p><p><strong>Results: </strong>Two kits showed clear deviations of measured thyrotropin levels when the human anti-mouse antibody titres were higher than 1350 micrograms/l. A third kit was influenced to a lesser extent by human anti-mouse antibodies. Three of the 6 investigated thyrotropin IRMA kits produced thyrotropin values that were unaffected by the presence of elevated human anti-mouse antibodies. In comparison with former studies after immunotherapy, the thyrotropin deviations were marginal. However, differences were found between the commercially available thyrotropin assays. According to the results of this study only three out of the six investigated kits were unaffected by human anti-mouse antibodies.</p><p><strong>Conclusion: </strong>Since thyrotropin is one of the key quantities for the endocrinologist dealing with the thyroid gland, every laboratory should ensure high quality thyrotropin assays by critically analysing their method for human anti-mouse antibody.</p>","PeriodicalId":77119,"journal":{"name":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","volume":"35 11","pages":"881-3"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of human anti-mouse antibodies on thyrotropin in-vitro analysis: a comparison of 6 thyrotropin IRMA kits.\",\"authors\":\"P Mikosch,&nbsp;H J Gallowitsch,&nbsp;E Kresnik,&nbsp;M Molnar,&nbsp;I Gomez,&nbsp;P Lind\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of the study was to evaluate the influence of human anti-mouse antibodies on the measurement of thyrotropin.</p><p><strong>Investigations: </strong>Samples from 11 patients with measureable human anti-mouse antibody titres (19 micrograms/l-3880 micrograms/l) after radioimmuno-scintigraphy were analysed with 6 different thyrotropin immuno-radiometric assay kits (IRMA). Each sample was analysed in the routine way (sample influenced by human anti-mouse antibodies), as well as after incubation with murine immunoglobulin to precipitate human anti-mouse antibodies (samples not influenced by human anti-mouse antibodies).</p><p><strong>Results: </strong>Two kits showed clear deviations of measured thyrotropin levels when the human anti-mouse antibody titres were higher than 1350 micrograms/l. A third kit was influenced to a lesser extent by human anti-mouse antibodies. Three of the 6 investigated thyrotropin IRMA kits produced thyrotropin values that were unaffected by the presence of elevated human anti-mouse antibodies. In comparison with former studies after immunotherapy, the thyrotropin deviations were marginal. However, differences were found between the commercially available thyrotropin assays. According to the results of this study only three out of the six investigated kits were unaffected by human anti-mouse antibodies.</p><p><strong>Conclusion: </strong>Since thyrotropin is one of the key quantities for the endocrinologist dealing with the thyroid gland, every laboratory should ensure high quality thyrotropin assays by critically analysing their method for human anti-mouse antibody.</p>\",\"PeriodicalId\":77119,\"journal\":{\"name\":\"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies\",\"volume\":\"35 11\",\"pages\":\"881-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨人抗小鼠抗体对促甲状腺素测定的影响。研究:用6种不同的促甲状腺素免疫放射测定试剂盒(IRMA)分析11例放射免疫扫描后可测定人抗小鼠抗体滴度(19微克/l-3880微克/l)的患者样本。每个样品按常规方法分析(受人抗小鼠抗体影响的样品),以及用小鼠免疫球蛋白孵育后沉淀人抗小鼠抗体(未受人抗小鼠抗体影响的样品)。结果:当人抗小鼠抗体滴度高于1350微克/升时,两种试剂盒测定的促甲状腺素水平有明显偏差。第三种试剂盒受人抗小鼠抗体的影响程度较小。6种促甲状腺素IRMA试剂盒中有3种产生的促甲状腺素值不受人抗小鼠抗体升高的影响。与以前的研究相比,免疫治疗后的促甲状腺激素偏差是微乎其微的。然而,在市售的促甲状腺素测定法之间发现了差异。根据这项研究的结果,六个被调查的试剂盒中只有三个不受人类抗小鼠抗体的影响。结论:促甲状腺素是甲状腺内分泌科医师的关键检测指标之一,各实验室应严格分析人抗小鼠抗体检测方法,确保促甲状腺素检测的高质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of human anti-mouse antibodies on thyrotropin in-vitro analysis: a comparison of 6 thyrotropin IRMA kits.

Objective: The aim of the study was to evaluate the influence of human anti-mouse antibodies on the measurement of thyrotropin.

Investigations: Samples from 11 patients with measureable human anti-mouse antibody titres (19 micrograms/l-3880 micrograms/l) after radioimmuno-scintigraphy were analysed with 6 different thyrotropin immuno-radiometric assay kits (IRMA). Each sample was analysed in the routine way (sample influenced by human anti-mouse antibodies), as well as after incubation with murine immunoglobulin to precipitate human anti-mouse antibodies (samples not influenced by human anti-mouse antibodies).

Results: Two kits showed clear deviations of measured thyrotropin levels when the human anti-mouse antibody titres were higher than 1350 micrograms/l. A third kit was influenced to a lesser extent by human anti-mouse antibodies. Three of the 6 investigated thyrotropin IRMA kits produced thyrotropin values that were unaffected by the presence of elevated human anti-mouse antibodies. In comparison with former studies after immunotherapy, the thyrotropin deviations were marginal. However, differences were found between the commercially available thyrotropin assays. According to the results of this study only three out of the six investigated kits were unaffected by human anti-mouse antibodies.

Conclusion: Since thyrotropin is one of the key quantities for the endocrinologist dealing with the thyroid gland, every laboratory should ensure high quality thyrotropin assays by critically analysing their method for human anti-mouse antibody.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synthesis and Characterization of Fatty Acid Furfuryl Ester Mixtures: Biodiesel from Furfuryl Alcohol Determination of Agmatine Rate by Spectrofluorimetric Method in Alkaline Medium: Optimization and Application on Shrimp. Increased Oxidative/Nitrosative Stress in Common Metabolic Diseases in Gaziantep Region nvironmental Monitoring of NOX, Total Oxidants and the Implications for Photochemistry of Air Pollution over Ilorin Shed, Nigeria Short Communication
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1