{"title":"呼吸器适合因素的性能,而出汗。","authors":"D M Caretti,&nbsp;P D Gardner","doi":"10.1080/00028899908984425","DOIUrl":null,"url":null,"abstract":"<p><p>The extent to which sweat accumulation inside respirators affects respirator fit has not been quantified. This study represents an attempt to measure facial sweating and to quantify its effects on fit factors of negative pressure, full-facepiece respirators. Respirator fit factor (FF) data were obtained while 14 subjects completed 30 minutes of treadmill walking at an intensity of 75% of age-predicted maximal heart rate in an aerosol test chamber under ambient environmental conditions. Subject facial and whole body sweat production were also measured. Statistical analysis of the treadmill FF results showed that respirator fit was significantly (p < 0.05) degraded after 14 minutes of exercise. Sweat accumulation inside the respirator facepiece averaged 30.9 +/- 15.5 g. However, no significant correlation of subject facial sweat production with overall FF values measured during exercise was found. The results of this study indicate that respirator FFs degrade significantly over time under moderate exercise and environmental conditions and suggest that facial sweat accumulation alone does not account for the reduced FF levels.</p>","PeriodicalId":7930,"journal":{"name":"American Industrial Hygiene Association journal","volume":"60 1","pages":"84-8"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00028899908984425","citationCount":"7","resultStr":"{\"title\":\"Respirator fit factor performance while sweating.\",\"authors\":\"D M Caretti,&nbsp;P D Gardner\",\"doi\":\"10.1080/00028899908984425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The extent to which sweat accumulation inside respirators affects respirator fit has not been quantified. This study represents an attempt to measure facial sweating and to quantify its effects on fit factors of negative pressure, full-facepiece respirators. Respirator fit factor (FF) data were obtained while 14 subjects completed 30 minutes of treadmill walking at an intensity of 75% of age-predicted maximal heart rate in an aerosol test chamber under ambient environmental conditions. Subject facial and whole body sweat production were also measured. Statistical analysis of the treadmill FF results showed that respirator fit was significantly (p < 0.05) degraded after 14 minutes of exercise. Sweat accumulation inside the respirator facepiece averaged 30.9 +/- 15.5 g. However, no significant correlation of subject facial sweat production with overall FF values measured during exercise was found. The results of this study indicate that respirator FFs degrade significantly over time under moderate exercise and environmental conditions and suggest that facial sweat accumulation alone does not account for the reduced FF levels.</p>\",\"PeriodicalId\":7930,\"journal\":{\"name\":\"American Industrial Hygiene Association journal\",\"volume\":\"60 1\",\"pages\":\"84-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00028899908984425\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Industrial Hygiene Association journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00028899908984425\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Industrial Hygiene Association journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00028899908984425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

口罩内积汗对口罩适配的影响程度尚未量化。本研究尝试测量面部出汗,并量化其对负压全面罩式呼吸器适配因子的影响。在环境条件下,14名受试者在气溶胶测试室内以年龄预测最大心率的75%的强度完成30分钟的跑步机步行,获得呼吸器适配因子(FF)数据。受试者面部和全身出汗量也被测量。对跑步机FF结果的统计分析显示,运动14分钟后,呼吸器配合度显著降低(p < 0.05)。口罩内积汗量平均为30.9±15.5 g。然而,没有发现受试者面部出汗量与运动期间测量的总体FF值有显著相关性。本研究结果表明,在适度运动和环境条件下,随着时间的推移,呼吸器的FF会显著降低,并表明面部汗液的累积本身并不能解释FF水平降低的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Respirator fit factor performance while sweating.

The extent to which sweat accumulation inside respirators affects respirator fit has not been quantified. This study represents an attempt to measure facial sweating and to quantify its effects on fit factors of negative pressure, full-facepiece respirators. Respirator fit factor (FF) data were obtained while 14 subjects completed 30 minutes of treadmill walking at an intensity of 75% of age-predicted maximal heart rate in an aerosol test chamber under ambient environmental conditions. Subject facial and whole body sweat production were also measured. Statistical analysis of the treadmill FF results showed that respirator fit was significantly (p < 0.05) degraded after 14 minutes of exercise. Sweat accumulation inside the respirator facepiece averaged 30.9 +/- 15.5 g. However, no significant correlation of subject facial sweat production with overall FF values measured during exercise was found. The results of this study indicate that respirator FFs degrade significantly over time under moderate exercise and environmental conditions and suggest that facial sweat accumulation alone does not account for the reduced FF levels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of leakage from a metal machining center using tracer gas methods: a case study. Assessment of magnetic field exposures for a mortality study at a uranium enrichment plant. An assessment of occupational noise exposures in four construction trades. Prediction of rectal temperature by the Questemp II personal heat strain monitor under low and moderate heat stress. The effects of keyswitch stiffness on typing force, finger electromyography, and subjective discomfort.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1