在“闪光”过程中的质量控制。

{"title":"在“闪光”过程中的质量控制。","authors":"","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This article has briefly discussed the three basic types of sterilization monitoring systems--mechanical, chemical, and biological. Mechanical indicators help tell you that the sterilizer is working. Chemical indicators provide you with immediate information in each \"flash\" load that the conditions necessary for steam sterilization were present. Biological indicators tell you that microorganisms were killed. For maximum assurance that the conditions necessary for steam sterilization are present and that non-sterile instruments are not inadvertently used, each \"flash\" sterilizer should be monitored daily with biological indicators and each \"flash\" load with chemical indicators. This quality control monitoring program should give the O.R. staff confidence that their \"flash\" sterilization process is working.</p>","PeriodicalId":79997,"journal":{"name":"Indicator (Minnesota Mining and Manfuacturing Company)","volume":"1 1","pages":"2p"},"PeriodicalIF":0.0000,"publicationDate":"1985-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quality control in the \\\"flash\\\" process.\",\"authors\":\"\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This article has briefly discussed the three basic types of sterilization monitoring systems--mechanical, chemical, and biological. Mechanical indicators help tell you that the sterilizer is working. Chemical indicators provide you with immediate information in each \\\"flash\\\" load that the conditions necessary for steam sterilization were present. Biological indicators tell you that microorganisms were killed. For maximum assurance that the conditions necessary for steam sterilization are present and that non-sterile instruments are not inadvertently used, each \\\"flash\\\" sterilizer should be monitored daily with biological indicators and each \\\"flash\\\" load with chemical indicators. This quality control monitoring program should give the O.R. staff confidence that their \\\"flash\\\" sterilization process is working.</p>\",\"PeriodicalId\":79997,\"journal\":{\"name\":\"Indicator (Minnesota Mining and Manfuacturing Company)\",\"volume\":\"1 1\",\"pages\":\"2p\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indicator (Minnesota Mining and Manfuacturing Company)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indicator (Minnesota Mining and Manfuacturing Company)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文简要讨论了三种基本类型的灭菌监测系统——机械、化学和生物。机械指示器帮助告诉你灭菌器正在工作。化学指标为您提供每个“闪蒸”负载的即时信息,表明蒸汽灭菌所需的条件已经存在。生物指标告诉你微生物被杀死了。为了最大限度地保证蒸汽灭菌所需的条件存在,并且不会无意中使用非无菌仪器,每个“闪蒸”灭菌器应每天用生物指标进行监测,每个“闪蒸”灭菌器应使用化学指标进行监测。这个质量控制监控程序应该给手术室的工作人员信心,他们的“闪蒸”灭菌过程是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quality control in the "flash" process.

This article has briefly discussed the three basic types of sterilization monitoring systems--mechanical, chemical, and biological. Mechanical indicators help tell you that the sterilizer is working. Chemical indicators provide you with immediate information in each "flash" load that the conditions necessary for steam sterilization were present. Biological indicators tell you that microorganisms were killed. For maximum assurance that the conditions necessary for steam sterilization are present and that non-sterile instruments are not inadvertently used, each "flash" sterilizer should be monitored daily with biological indicators and each "flash" load with chemical indicators. This quality control monitoring program should give the O.R. staff confidence that their "flash" sterilization process is working.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Aeration of EO-sterilized items. Value analysis. OSHA EO standard. Quality control in the "flash" process. Value analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1