{"title":"高血压患者拔牙过程中血压及脉搏变化的评价。","authors":"M Gungormus, M C Buyukkurt","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this investigation was to evaluate the changes in blood pressure and the pulse rate of hypertensive patients having dental extraction under a local anesthetic containing a vasopressor. The study included 64 patients (42 female and 22 male), 38 to 78 years of age. Twenty-six of the patients were normotensive, 38 were hypertensive patients. The hypertensive patients were identified as those patients who had histories of medically diagnosed high blood pressure and baseline recordings of blood pressures higher than 140/90 mm Hg. Articain HCl with 0.012 mg epinephrine hydrochloride, was used as the local anesthetic for all patients and one tooth was extracted from each patient. Blood pressure and pulse rate measurements were recorded immediately prior to anesthesia, just before extraction and 5 minutes after extraction. The data were analyzed by a two-way ANOVA with repeated measures. Analysis of the data indicated no statistically significant changes in the systolic and diastolic blood pressures and pulse rate for all interval measurements in both normotensive and hypertensive patients (P > 0.05). In this study, it was determined that there were no significant changes in the blood pressures and the pulse rate of hypertensive patients during surgical procedure, and one cartridge local anesthetic with articain HCl containing 0.012 mg pinephrine may be used safely in hypertensive patients with blood pressure equal or smaller than 154/99 mm Hg.</p>","PeriodicalId":6945,"journal":{"name":"Acta medica Austriaca","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The evaluation of the changes in blood pressure and pulse rate of hypertensive patients during tooth extraction.\",\"authors\":\"M Gungormus, M C Buyukkurt\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this investigation was to evaluate the changes in blood pressure and the pulse rate of hypertensive patients having dental extraction under a local anesthetic containing a vasopressor. The study included 64 patients (42 female and 22 male), 38 to 78 years of age. Twenty-six of the patients were normotensive, 38 were hypertensive patients. The hypertensive patients were identified as those patients who had histories of medically diagnosed high blood pressure and baseline recordings of blood pressures higher than 140/90 mm Hg. Articain HCl with 0.012 mg epinephrine hydrochloride, was used as the local anesthetic for all patients and one tooth was extracted from each patient. Blood pressure and pulse rate measurements were recorded immediately prior to anesthesia, just before extraction and 5 minutes after extraction. The data were analyzed by a two-way ANOVA with repeated measures. Analysis of the data indicated no statistically significant changes in the systolic and diastolic blood pressures and pulse rate for all interval measurements in both normotensive and hypertensive patients (P > 0.05). In this study, it was determined that there were no significant changes in the blood pressures and the pulse rate of hypertensive patients during surgical procedure, and one cartridge local anesthetic with articain HCl containing 0.012 mg pinephrine may be used safely in hypertensive patients with blood pressure equal or smaller than 154/99 mm Hg.</p>\",\"PeriodicalId\":6945,\"journal\":{\"name\":\"Acta medica Austriaca\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta medica Austriaca\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta medica Austriaca","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究的目的是评估在含血管加压剂的局部麻醉下拔牙的高血压患者血压和脉搏率的变化。研究纳入64例患者(女性42例,男性22例),年龄38 ~ 78岁。正常血压26例,高血压38例。高血压患者是指有医学诊断的高血压病史和血压基线记录高于140/90 mm Hg的患者。所有患者局部麻醉均采用盐酸Articain HCl加0.012 mg盐酸肾上腺素,每例患者拔牙1颗。在麻醉前、拔牙前和拔牙后5分钟分别记录血压和脉搏测量。数据采用重复测量的双向方差分析。数据分析显示,正常血压和高血压患者的收缩压、舒张压和脉搏率在所有间隔测量中均无统计学意义变化(P > 0.05)。本研究确定高血压患者在手术过程中血压和脉搏率无明显变化,对于血压等于或小于154/99 mm Hg的高血压患者,可安全使用含0.012 mg肾上腺素的盐酸关节剂一盒局麻药。
The evaluation of the changes in blood pressure and pulse rate of hypertensive patients during tooth extraction.
The purpose of this investigation was to evaluate the changes in blood pressure and the pulse rate of hypertensive patients having dental extraction under a local anesthetic containing a vasopressor. The study included 64 patients (42 female and 22 male), 38 to 78 years of age. Twenty-six of the patients were normotensive, 38 were hypertensive patients. The hypertensive patients were identified as those patients who had histories of medically diagnosed high blood pressure and baseline recordings of blood pressures higher than 140/90 mm Hg. Articain HCl with 0.012 mg epinephrine hydrochloride, was used as the local anesthetic for all patients and one tooth was extracted from each patient. Blood pressure and pulse rate measurements were recorded immediately prior to anesthesia, just before extraction and 5 minutes after extraction. The data were analyzed by a two-way ANOVA with repeated measures. Analysis of the data indicated no statistically significant changes in the systolic and diastolic blood pressures and pulse rate for all interval measurements in both normotensive and hypertensive patients (P > 0.05). In this study, it was determined that there were no significant changes in the blood pressures and the pulse rate of hypertensive patients during surgical procedure, and one cartridge local anesthetic with articain HCl containing 0.012 mg pinephrine may be used safely in hypertensive patients with blood pressure equal or smaller than 154/99 mm Hg.