用共价有机骨架和聚吡咯复合吸附剂在填充注射器中微萃取联合高效液相色谱/紫外分光光度法测定尿样中的阿片类药物

IF 4.1 Q1 CHEMISTRY, ANALYTICAL Talanta Open Pub Date : 2023-08-01 DOI:10.1016/j.talo.2023.100183
Fatemeh Zanganeh , Yadollah Yamini , Mohammad Mahdi Khataei , Mahboube Shirani
{"title":"用共价有机骨架和聚吡咯复合吸附剂在填充注射器中微萃取联合高效液相色谱/紫外分光光度法测定尿样中的阿片类药物","authors":"Fatemeh Zanganeh ,&nbsp;Yadollah Yamini ,&nbsp;Mohammad Mahdi Khataei ,&nbsp;Mahboube Shirani","doi":"10.1016/j.talo.2023.100183","DOIUrl":null,"url":null,"abstract":"<div><p>This study aimed to develop microextraction in a packed syringe (MEPS) method for the determination of the three opiates in urine samples. Covalent organic framework-polypyrrole- cetyltrimethylammonium bromide <strong>(</strong>COF-PPy-CTAB) nanocomposite, as an appropriate and highly efficient adsorbent, was synthesized and applied to the MEPS process. The analytes were separated and extracted on the solid phase surface of the adsorbent through π stacking, hydrophobic, and host-guest interaction and then eluted by a desorbing solvent. After synthesizing the composite and using it in the syringe as a substrate for analyte adsorption, the parameters affecting the extraction of the analytes were optimized and the calibration curve was obtained according to the optimum conditions. The results were linear in the concentration range of 0.5–1000 μg L <sup>−</sup> <sup>1</sup> with a coefficient of determination greater than 0.9945. The limits of detection and quantification were obtained in the range of (0.1–1.0) and (0.5–5.0) μg L<sup>‒1</sup>, respectively. The precision of the work was obtained for a syringe in a day and between days and also syringe to syringe in the range of 4.4–6.1%, 6.5–8.1%, and 7.8–10.1%, respectively. The preconcentration factors of 17, 20, and 16 were obtained for codeine, papaverine, and naltrexone, respectively. Relative recoveries of the drugs from urine samples were in acceptable range of 94.4–100.6% for codeine, 99.3–103.1% for papaverine and 95.0–98.9% for naltrexone.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"7 ","pages":"Article 100183"},"PeriodicalIF":4.1000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Determination of opiates in urine samples using a composite of covalent organic framework and polypyrrole as a sorbent for microextraction in a packed syringe combined with HPLC/UV\",\"authors\":\"Fatemeh Zanganeh ,&nbsp;Yadollah Yamini ,&nbsp;Mohammad Mahdi Khataei ,&nbsp;Mahboube Shirani\",\"doi\":\"10.1016/j.talo.2023.100183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study aimed to develop microextraction in a packed syringe (MEPS) method for the determination of the three opiates in urine samples. Covalent organic framework-polypyrrole- cetyltrimethylammonium bromide <strong>(</strong>COF-PPy-CTAB) nanocomposite, as an appropriate and highly efficient adsorbent, was synthesized and applied to the MEPS process. The analytes were separated and extracted on the solid phase surface of the adsorbent through π stacking, hydrophobic, and host-guest interaction and then eluted by a desorbing solvent. After synthesizing the composite and using it in the syringe as a substrate for analyte adsorption, the parameters affecting the extraction of the analytes were optimized and the calibration curve was obtained according to the optimum conditions. The results were linear in the concentration range of 0.5–1000 μg L <sup>−</sup> <sup>1</sup> with a coefficient of determination greater than 0.9945. The limits of detection and quantification were obtained in the range of (0.1–1.0) and (0.5–5.0) μg L<sup>‒1</sup>, respectively. The precision of the work was obtained for a syringe in a day and between days and also syringe to syringe in the range of 4.4–6.1%, 6.5–8.1%, and 7.8–10.1%, respectively. The preconcentration factors of 17, 20, and 16 were obtained for codeine, papaverine, and naltrexone, respectively. Relative recoveries of the drugs from urine samples were in acceptable range of 94.4–100.6% for codeine, 99.3–103.1% for papaverine and 95.0–98.9% for naltrexone.</p></div>\",\"PeriodicalId\":436,\"journal\":{\"name\":\"Talanta Open\",\"volume\":\"7 \",\"pages\":\"Article 100183\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666831923000048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831923000048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 3

摘要

本研究旨在建立在包装注射器(MEPS)中微萃取测定尿液样品中三种阿片类药物的方法。合成了共价有机骨架-聚吡咯-十六烷基三甲基溴化铵(cof - py - ctab)纳米复合材料,作为一种合适的高效吸附剂,并应用于MEPS工艺。分析物通过π堆积、疏水和主客体相互作用在吸附剂的固相表面分离和提取,然后用解吸溶剂洗脱。合成该复合材料,在注射器中作为分析物吸附底物,对影响分析物提取的参数进行优化,并根据最佳条件获得校准曲线。结果在0.5 ~ 1000 μg L−1浓度范围内呈线性关系,测定系数大于0.9945。检测限和定量限分别在(0.1 ~ 1.0)和(0.5 ~ 5.0)μ L-1范围内。在一天内、天之间以及注射器与注射器之间的工作精度分别为4.4-6.1%、6.5-8.1%和7.8-10.1%。可待因、罂粟碱和纳曲酮的预富集因子分别为17、20和16。尿液样品中可待因的相对回收率为94.4 ~ 100.6%,罂粟碱的相对回收率为99.3 ~ 103.1%,纳曲酮的相对回收率为95.0 ~ 98.9%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of opiates in urine samples using a composite of covalent organic framework and polypyrrole as a sorbent for microextraction in a packed syringe combined with HPLC/UV

This study aimed to develop microextraction in a packed syringe (MEPS) method for the determination of the three opiates in urine samples. Covalent organic framework-polypyrrole- cetyltrimethylammonium bromide (COF-PPy-CTAB) nanocomposite, as an appropriate and highly efficient adsorbent, was synthesized and applied to the MEPS process. The analytes were separated and extracted on the solid phase surface of the adsorbent through π stacking, hydrophobic, and host-guest interaction and then eluted by a desorbing solvent. After synthesizing the composite and using it in the syringe as a substrate for analyte adsorption, the parameters affecting the extraction of the analytes were optimized and the calibration curve was obtained according to the optimum conditions. The results were linear in the concentration range of 0.5–1000 μg L  1 with a coefficient of determination greater than 0.9945. The limits of detection and quantification were obtained in the range of (0.1–1.0) and (0.5–5.0) μg L‒1, respectively. The precision of the work was obtained for a syringe in a day and between days and also syringe to syringe in the range of 4.4–6.1%, 6.5–8.1%, and 7.8–10.1%, respectively. The preconcentration factors of 17, 20, and 16 were obtained for codeine, papaverine, and naltrexone, respectively. Relative recoveries of the drugs from urine samples were in acceptable range of 94.4–100.6% for codeine, 99.3–103.1% for papaverine and 95.0–98.9% for naltrexone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil Development of engineered Zn-MOF/g-C3N4 based photoelectrochemical system for real-time sensors and removal of naproxen in wastewater Development of nanomaterial-supported molecularly imprinted polymer/receptor-like sensor for the detection of rosuvastatin from binary mixtures Trace-level quantification of NDMA in levosulpuride active pharmaceutical ingredient and tablet formulation Using UFLC-MS/MS Enhancing isomer specificity in mass spectrometry by combining silver ion adduction and ion mobility
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1