{"title":"患者可以在急诊科准确地进行自己的快速艾滋病毒即时检测。","authors":"Samah Nour, Yu-Hsiang Hsieh, Richard E Rothman, Mary Jett-Goheen, Ophelia Langhorne, Lan Wu, Stephen Peterson, Charlotte A Gaydos","doi":"10.1097/POC.0b013e3182666eb7","DOIUrl":null,"url":null,"abstract":"OBJECTIVE The objective of this study was to evaluate the feasibility, acceptability, and accuracy of having emergency department (ED) patients perform a rapid, point-of-care (POC) self-test for HIV before routine HIV testing. METHODS Patients aged 18 to 65 years were recruited to perform a rapid POC HIV oral fluid at The Johns Hopkins ED in conjunction with the standard-of-care HIV POC test. Acceptability and ease of use were assessed by a questionnaire. RESULTS A total of 259 patients were approached for testing, and 249 (96.1%) consented to perform a self POC HIV test. Of patients performing a self-test, 100% had concordant results with those obtained by the health care worker. Four females (1.6%) were newly identified as HIV positive. Median participant age was 41 years, and 58% of patients were female; 83% were African American, and 16% were white. Overall, greater than 90% of patients reported trust of the test results, ease of testing, and willingness to test again. Approximately 35% of patients indicated they would pay up to a maximum price of $30 for testing. Overall, 46.9% of patients preferred self-testing, and 39.5% preferred health care professional testing. Regarding preferred location for testing, 51.0% preferred home self-testing, 39.5% preferred clinic/ED self-testing (P > 0.05), and 9.5% had no preference. CONCLUSIONS A significant proportion of patients offered POC testing in the ED agreed to perform a self-HIV test. Patients' results were concordant with those obtained by the health care worker; 1.6% were HIV positive. The majority of participants believed the veracity of their results. A greater number of patients preferred self-testing.","PeriodicalId":44085,"journal":{"name":"Point of Care","volume":"11 4","pages":"176-179"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/POC.0b013e3182666eb7","citationCount":"18","resultStr":"{\"title\":\"Patients Can Accurately Perform Their Own Rapid HIV Point-of-Care Test in the Emergency Department.\",\"authors\":\"Samah Nour, Yu-Hsiang Hsieh, Richard E Rothman, Mary Jett-Goheen, Ophelia Langhorne, Lan Wu, Stephen Peterson, Charlotte A Gaydos\",\"doi\":\"10.1097/POC.0b013e3182666eb7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE The objective of this study was to evaluate the feasibility, acceptability, and accuracy of having emergency department (ED) patients perform a rapid, point-of-care (POC) self-test for HIV before routine HIV testing. METHODS Patients aged 18 to 65 years were recruited to perform a rapid POC HIV oral fluid at The Johns Hopkins ED in conjunction with the standard-of-care HIV POC test. Acceptability and ease of use were assessed by a questionnaire. RESULTS A total of 259 patients were approached for testing, and 249 (96.1%) consented to perform a self POC HIV test. Of patients performing a self-test, 100% had concordant results with those obtained by the health care worker. Four females (1.6%) were newly identified as HIV positive. Median participant age was 41 years, and 58% of patients were female; 83% were African American, and 16% were white. Overall, greater than 90% of patients reported trust of the test results, ease of testing, and willingness to test again. Approximately 35% of patients indicated they would pay up to a maximum price of $30 for testing. Overall, 46.9% of patients preferred self-testing, and 39.5% preferred health care professional testing. Regarding preferred location for testing, 51.0% preferred home self-testing, 39.5% preferred clinic/ED self-testing (P > 0.05), and 9.5% had no preference. CONCLUSIONS A significant proportion of patients offered POC testing in the ED agreed to perform a self-HIV test. Patients' results were concordant with those obtained by the health care worker; 1.6% were HIV positive. The majority of participants believed the veracity of their results. A greater number of patients preferred self-testing.\",\"PeriodicalId\":44085,\"journal\":{\"name\":\"Point of Care\",\"volume\":\"11 4\",\"pages\":\"176-179\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/POC.0b013e3182666eb7\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Point of Care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/POC.0b013e3182666eb7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Nursing\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0b013e3182666eb7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Nursing","Score":null,"Total":0}
引用次数: 18

摘要

目的:本研究的目的是评估急诊科(ED)患者在常规HIV检测前进行快速、即时(POC)自我检测HIV的可行性、可接受性和准确性。方法:招募年龄在18至65岁之间的患者,在约翰霍普金斯急诊科进行快速POC HIV口服液检测,并结合标准护理HIV POC检测。通过问卷评估可接受性和易用性。结果:共接触259例患者进行检测,其中249例(96.1%)同意进行自我POC HIV检测。在进行自我测试的患者中,100%的结果与卫生保健工作者获得的结果一致。4名女性(1.6%)新近被确定为艾滋病毒阳性。参与者的中位年龄为41岁,58%的患者为女性;83%是非洲裔美国人,16%是白人。总体而言,超过90%的患者报告了对检测结果的信任,检测的便利性和再次检测的意愿。大约35%的患者表示,他们愿意为检测支付最高30美元的费用。总体而言,46.9%的患者倾向于自我检测,39.5%的患者倾向于卫生保健专业人员检测。在选择检测地点方面,51.0%的人倾向于家庭自检,39.5%的人倾向于诊所/急诊科自检(P > 0.05), 9.5%的人没有选择。结论:在急诊科接受POC检测的患者中,有相当大比例的人同意进行自我hiv检测。患者的结果与卫生保健工作者的结果一致;1.6%为HIV阳性。大多数参与者相信他们的结果是真实的。更多的患者倾向于自我检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Patients Can Accurately Perform Their Own Rapid HIV Point-of-Care Test in the Emergency Department.
OBJECTIVE The objective of this study was to evaluate the feasibility, acceptability, and accuracy of having emergency department (ED) patients perform a rapid, point-of-care (POC) self-test for HIV before routine HIV testing. METHODS Patients aged 18 to 65 years were recruited to perform a rapid POC HIV oral fluid at The Johns Hopkins ED in conjunction with the standard-of-care HIV POC test. Acceptability and ease of use were assessed by a questionnaire. RESULTS A total of 259 patients were approached for testing, and 249 (96.1%) consented to perform a self POC HIV test. Of patients performing a self-test, 100% had concordant results with those obtained by the health care worker. Four females (1.6%) were newly identified as HIV positive. Median participant age was 41 years, and 58% of patients were female; 83% were African American, and 16% were white. Overall, greater than 90% of patients reported trust of the test results, ease of testing, and willingness to test again. Approximately 35% of patients indicated they would pay up to a maximum price of $30 for testing. Overall, 46.9% of patients preferred self-testing, and 39.5% preferred health care professional testing. Regarding preferred location for testing, 51.0% preferred home self-testing, 39.5% preferred clinic/ED self-testing (P > 0.05), and 9.5% had no preference. CONCLUSIONS A significant proportion of patients offered POC testing in the ED agreed to perform a self-HIV test. Patients' results were concordant with those obtained by the health care worker; 1.6% were HIV positive. The majority of participants believed the veracity of their results. A greater number of patients preferred self-testing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Point of Care
Point of Care MEDICAL LABORATORY TECHNOLOGY-
自引率
0.00%
发文量
0
期刊介绍: Point of Care: The Journal of Near-Patient Testing & Technology is a vital resource for directors and managers of large and small hospital pathology labs, blood centers, home health-care agencies, doctors" offices, and other healthcare facilities. Each issue brings you peer-reviewed original research articles, along with concepts, technologies and trends, covering topics that include: Test accuracy Turnaround time Data management Quality control Regulatory compliance Cost-effectiveness of testing
期刊最新文献
Patient Preferences for Point-of-Care Testing: Survey Validation and Results. Overcoming Challenges with the Adoption of Point-of-Care Testing: From Technology Push and Clinical Needs to Value Propositions. Toward Improving Accessibility of Point-of-Care Diagnostic Services for Maternal and Child Health in Low- and Middle-Income Countries. Point-of-Care Diagnosis of Acute Myocardial Infarction in Central Vietnam: International Exchange, Needs Assessment, and Spatial Care Paths. Healthcare worker feedback on a prototype smartphone-based point-of-care test platform for use in episodic care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1