唾液样品中镁的微流控纸基分析装置的研制

IF 4.1 Q1 CHEMISTRY, ANALYTICAL Talanta Open Pub Date : 2022-12-01 DOI:10.1016/j.talo.2022.100135
Juliana I.S. Aguiar, Mafalda T.S. Silva, Helena A.G. Ferreira, Elisabete C.B. Pinto, Marta W. Vasconcelos, António O.S.S. Rangel, Raquel B.R. Mesquita
{"title":"唾液样品中镁的微流控纸基分析装置的研制","authors":"Juliana I.S. Aguiar,&nbsp;Mafalda T.S. Silva,&nbsp;Helena A.G. Ferreira,&nbsp;Elisabete C.B. Pinto,&nbsp;Marta W. Vasconcelos,&nbsp;António O.S.S. Rangel,&nbsp;Raquel B.R. Mesquita","doi":"10.1016/j.talo.2022.100135","DOIUrl":null,"url":null,"abstract":"<div><p>In this work, a microfluidic paper-based analytical device (μPAD) was developed for magnesium determination in saliva samples. The idea was to develop a fast and simple method for biological magnesium quantification targeting saliva as an easy to collect and non-invasive alternative to blood or urine samples. The μPAD approach was chosen due to its advantages, namely ideally suited to conduct on-location determinations, and not requiring trained operators or specialized laboratory equipment. The developed μPAD was based on the colorimetric reaction between eriochrome cyanine and magnesium to form an intense orange/reddish colour product. The colour intensity was determined by image processing after digital scanning, made within 10 to 90 min after sample loading. Under optimal conditions, the dynamic concentration range was 82–247 μM, with detection and quantification limits of 62 μM and 81 μM, respectively. The device is stable for up to 3 months when stored in vacuum or in a modified nitrogen atmosphere. An accuracy assessment was made by comparing the results obtained using the developed μPAD with those from atomic absorption spectrometry (AAS). The relative difference between the two sets of results was below 5%.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"6 ","pages":"Article 100135"},"PeriodicalIF":4.1000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Development of a microfluidic paper-based analytical device for magnesium determination in saliva samples\",\"authors\":\"Juliana I.S. Aguiar,&nbsp;Mafalda T.S. Silva,&nbsp;Helena A.G. Ferreira,&nbsp;Elisabete C.B. Pinto,&nbsp;Marta W. Vasconcelos,&nbsp;António O.S.S. Rangel,&nbsp;Raquel B.R. Mesquita\",\"doi\":\"10.1016/j.talo.2022.100135\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this work, a microfluidic paper-based analytical device (μPAD) was developed for magnesium determination in saliva samples. The idea was to develop a fast and simple method for biological magnesium quantification targeting saliva as an easy to collect and non-invasive alternative to blood or urine samples. The μPAD approach was chosen due to its advantages, namely ideally suited to conduct on-location determinations, and not requiring trained operators or specialized laboratory equipment. The developed μPAD was based on the colorimetric reaction between eriochrome cyanine and magnesium to form an intense orange/reddish colour product. The colour intensity was determined by image processing after digital scanning, made within 10 to 90 min after sample loading. Under optimal conditions, the dynamic concentration range was 82–247 μM, with detection and quantification limits of 62 μM and 81 μM, respectively. The device is stable for up to 3 months when stored in vacuum or in a modified nitrogen atmosphere. An accuracy assessment was made by comparing the results obtained using the developed μPAD with those from atomic absorption spectrometry (AAS). The relative difference between the two sets of results was below 5%.</p></div>\",\"PeriodicalId\":436,\"journal\":{\"name\":\"Talanta Open\",\"volume\":\"6 \",\"pages\":\"Article 100135\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666831922000522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831922000522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 4

摘要

本文建立了一种用于唾液样品中镁含量测定的微流控纸基分析装置(μPAD)。他们的想法是开发一种快速简单的生物镁定量方法,以唾液为目标,作为血液或尿液样本的一种易于收集和非侵入性的替代方法。选择μPAD方法是因为其优点,即非常适合进行现场测定,并且不需要训练有素的操作人员或专门的实验室设备。所研制的μPAD是基于铬菁与镁的比色反应,生成浓桔红色的产物。颜色强度由数字扫描后的图像处理确定,在样品加载后10至90分钟内完成。在最佳条件下,动态浓度范围为82 ~ 247 μM,检测限为62 μM,定量限为81 μM。该装置在真空或改性氮气气氛中储存时可稳定长达3个月。将所建立的μPAD测定结果与原子吸收光谱法(AAS)测定结果进行了准确性评价。两组结果的相对差异小于5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of a microfluidic paper-based analytical device for magnesium determination in saliva samples

In this work, a microfluidic paper-based analytical device (μPAD) was developed for magnesium determination in saliva samples. The idea was to develop a fast and simple method for biological magnesium quantification targeting saliva as an easy to collect and non-invasive alternative to blood or urine samples. The μPAD approach was chosen due to its advantages, namely ideally suited to conduct on-location determinations, and not requiring trained operators or specialized laboratory equipment. The developed μPAD was based on the colorimetric reaction between eriochrome cyanine and magnesium to form an intense orange/reddish colour product. The colour intensity was determined by image processing after digital scanning, made within 10 to 90 min after sample loading. Under optimal conditions, the dynamic concentration range was 82–247 μM, with detection and quantification limits of 62 μM and 81 μM, respectively. The device is stable for up to 3 months when stored in vacuum or in a modified nitrogen atmosphere. An accuracy assessment was made by comparing the results obtained using the developed μPAD with those from atomic absorption spectrometry (AAS). The relative difference between the two sets of results was below 5%.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil Development of engineered Zn-MOF/g-C3N4 based photoelectrochemical system for real-time sensors and removal of naproxen in wastewater Development of nanomaterial-supported molecularly imprinted polymer/receptor-like sensor for the detection of rosuvastatin from binary mixtures Trace-level quantification of NDMA in levosulpuride active pharmaceutical ingredient and tablet formulation Using UFLC-MS/MS Enhancing isomer specificity in mass spectrometry by combining silver ion adduction and ion mobility
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1