利用工程氧不敏感甘油3-磷酸氧化酶进行甘油三酯监测的交叉电极酶传感器的研制

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Sensors and Actuators Reports Pub Date : 2023-06-01 DOI:10.1016/j.snr.2023.100164
Inyoung Lee , Sheng Tong , Mika Hatada , Adrianna Masterson , Kentaro Hiraka , Junko Okuda-Shimazaki , Wakako Tsugawa , Gary Hughes , Koji Sode
{"title":"利用工程氧不敏感甘油3-磷酸氧化酶进行甘油三酯监测的交叉电极酶传感器的研制","authors":"Inyoung Lee ,&nbsp;Sheng Tong ,&nbsp;Mika Hatada ,&nbsp;Adrianna Masterson ,&nbsp;Kentaro Hiraka ,&nbsp;Junko Okuda-Shimazaki ,&nbsp;Wakako Tsugawa ,&nbsp;Gary Hughes ,&nbsp;Koji Sode","doi":"10.1016/j.snr.2023.100164","DOIUrl":null,"url":null,"abstract":"<div><p>Triglycerides (TG) are an important biomarker of various diseases including hyper-lipidemia. Current emergent requirements for TG sensing include the development of electrochemical sensors for easy, cost-effective, disposable and single use triglyceride sensors. We propose a TG sensor using an engineered glycerol 3-phosphate oxidase (GlpO) and electrochemical detection. In this study, we aimed to develop an electrochemical TG sensor based on engineering the oxidative half reaction of GlpO to be oxygen insensitive, with the employment of an interdigitated electrode (IDE). To construct an oxygen insensitive mutant GlpO, we constructed a double mutant, Met104Phe/Asp169Glu, which revealed an engineered GlpO exhibiting repressed oxidase activity, while its dye-mediated dehydrogenase activity enhanced. The electrochemical enzyme sensor was constructed for the measurement of TG based on engineered GlpO using disposable screen-printed carbon electrode (SPCE) or disposable IDE using Ru complex as the electron mediator. By using the disposable IDE sensor, a highly sensitive electrochemical sensor for Glp was achieved, with the sensitivity of 0.4 µA/mM. The improved sensitivity was 2.4 times higher than that of SPCE (0.17 µA/mM), with LOD of 0.022 mM. Furthermore, the dry sensor strip, where the double mutant GlpO and Ru complex were dropcasted and dried on the IDE, was prepared and the Glp concentration was successfully measured in the delipidized serum solution. Therefore, by the employment of the established pretreatment method for TG to release Glp, a highly sensitive, accurate, easy and rapid electrochemical measurement method for TG will be developed using constructed M104F/D169E mutant GlpO with the combination of IDE.</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"5 ","pages":"Article 100164"},"PeriodicalIF":6.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of interdigitated electrode based enzyme sensor for triglyceride monitoring using engineered oxygen insensitive glycerol 3-phosphate oxidase\",\"authors\":\"Inyoung Lee ,&nbsp;Sheng Tong ,&nbsp;Mika Hatada ,&nbsp;Adrianna Masterson ,&nbsp;Kentaro Hiraka ,&nbsp;Junko Okuda-Shimazaki ,&nbsp;Wakako Tsugawa ,&nbsp;Gary Hughes ,&nbsp;Koji Sode\",\"doi\":\"10.1016/j.snr.2023.100164\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Triglycerides (TG) are an important biomarker of various diseases including hyper-lipidemia. Current emergent requirements for TG sensing include the development of electrochemical sensors for easy, cost-effective, disposable and single use triglyceride sensors. We propose a TG sensor using an engineered glycerol 3-phosphate oxidase (GlpO) and electrochemical detection. In this study, we aimed to develop an electrochemical TG sensor based on engineering the oxidative half reaction of GlpO to be oxygen insensitive, with the employment of an interdigitated electrode (IDE). To construct an oxygen insensitive mutant GlpO, we constructed a double mutant, Met104Phe/Asp169Glu, which revealed an engineered GlpO exhibiting repressed oxidase activity, while its dye-mediated dehydrogenase activity enhanced. The electrochemical enzyme sensor was constructed for the measurement of TG based on engineered GlpO using disposable screen-printed carbon electrode (SPCE) or disposable IDE using Ru complex as the electron mediator. By using the disposable IDE sensor, a highly sensitive electrochemical sensor for Glp was achieved, with the sensitivity of 0.4 µA/mM. The improved sensitivity was 2.4 times higher than that of SPCE (0.17 µA/mM), with LOD of 0.022 mM. Furthermore, the dry sensor strip, where the double mutant GlpO and Ru complex were dropcasted and dried on the IDE, was prepared and the Glp concentration was successfully measured in the delipidized serum solution. Therefore, by the employment of the established pretreatment method for TG to release Glp, a highly sensitive, accurate, easy and rapid electrochemical measurement method for TG will be developed using constructed M104F/D169E mutant GlpO with the combination of IDE.</p></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":\"5 \",\"pages\":\"Article 100164\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053923000279\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053923000279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

甘油三酯(TG)是包括高脂血症在内的多种疾病的重要生物标志物。目前对TG传感的迫切需求包括开发电化学传感器,以实现简单、经济、一次性和一次性的甘油三酯传感器。我们提出了一种使用工程甘油3-磷酸氧化酶(GlpO)和电化学检测的TG传感器。在这项研究中,我们的目标是开发一种电化学热重传感器,该传感器基于对GlpO氧化半反应进行工程改造,使其对氧不敏感,并采用交叉指状电极(IDE)。为了构建一个氧不敏感突变体GlpO,我们构建了一个双突变体Met104Phe/Asp169Glu,该突变体显示出氧化酶活性被抑制,而染料介导的脱氢酶活性增强。采用一次性丝网印刷碳电极(SPCE)或一次性IDE (Ru配合物)作为电子介质,构建了基于工程GlpO的电化学酶传感器来测量TG。利用一次性IDE传感器,实现了高灵敏度的Glp电化学传感器,灵敏度为0.4µa /mM。改进后的灵敏度是SPCE的2.4倍(0.17µA/mM), LOD为0.022 mM。此外,制备了将双突变GlpO和Ru配合物滴注在IDE上干燥的干燥传感器条,并成功地在脱水血清溶液中测量了Glp浓度。因此,利用已建立的TG前处理方法释放Glp,将构建的M104F/D169E突变体GlpO与IDE相结合,开发一种高灵敏、准确、简便、快速的TG电化学测量方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of interdigitated electrode based enzyme sensor for triglyceride monitoring using engineered oxygen insensitive glycerol 3-phosphate oxidase

Triglycerides (TG) are an important biomarker of various diseases including hyper-lipidemia. Current emergent requirements for TG sensing include the development of electrochemical sensors for easy, cost-effective, disposable and single use triglyceride sensors. We propose a TG sensor using an engineered glycerol 3-phosphate oxidase (GlpO) and electrochemical detection. In this study, we aimed to develop an electrochemical TG sensor based on engineering the oxidative half reaction of GlpO to be oxygen insensitive, with the employment of an interdigitated electrode (IDE). To construct an oxygen insensitive mutant GlpO, we constructed a double mutant, Met104Phe/Asp169Glu, which revealed an engineered GlpO exhibiting repressed oxidase activity, while its dye-mediated dehydrogenase activity enhanced. The electrochemical enzyme sensor was constructed for the measurement of TG based on engineered GlpO using disposable screen-printed carbon electrode (SPCE) or disposable IDE using Ru complex as the electron mediator. By using the disposable IDE sensor, a highly sensitive electrochemical sensor for Glp was achieved, with the sensitivity of 0.4 µA/mM. The improved sensitivity was 2.4 times higher than that of SPCE (0.17 µA/mM), with LOD of 0.022 mM. Furthermore, the dry sensor strip, where the double mutant GlpO and Ru complex were dropcasted and dried on the IDE, was prepared and the Glp concentration was successfully measured in the delipidized serum solution. Therefore, by the employment of the established pretreatment method for TG to release Glp, a highly sensitive, accurate, easy and rapid electrochemical measurement method for TG will be developed using constructed M104F/D169E mutant GlpO with the combination of IDE.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
期刊最新文献
A highly sensitive microfluidic biosensor for rapid and accurate detection of Salmonella in raw chicken products Enhancing nitrous oxide chemiresistive sensing performance by reducing ionic Oxygen species adsorption in Gold functionalized Tungsten Trioxide nanofibers Critical review of hydrogen cyanide (HCN) sensors and their applications 1D supramolecular assembly-induced emission and colorimetry toward precise onsite mercury(II) detection Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1