CT透视下经皮肾肿块冷冻消融:对患者和介入医师的辐射剂量。

Jessica K Stewart, Christopher B Looney, Colin D Anderson-Evans, Greta I Toncheva, David R Sopko, Charles Y Kim, Terry T Yoshizumi, Rendon C Nelson
{"title":"CT透视下经皮肾肿块冷冻消融:对患者和介入医师的辐射剂量。","authors":"Jessica K Stewart,&nbsp;Christopher B Looney,&nbsp;Colin D Anderson-Evans,&nbsp;Greta I Toncheva,&nbsp;David R Sopko,&nbsp;Charles Y Kim,&nbsp;Terry T Yoshizumi,&nbsp;Rendon C Nelson","doi":"10.1007/s00261-015-0456-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Computed tomographic (CT) fluoroscopy-guided percutaneous cryoablation is an effective therapeutic method used to treat focal renal masses. The purpose of this study is to quantify the radiation dose to the patient and interventional radiologist during percutaneous cryoablation of renal masses using CT fluoroscopic guidance.</p><p><strong>Methods: </strong>Over a 1-year period, the CT fluoroscopy time during percutaneous cryoablation of renal masses was recorded in 41 patients. The level of complexity of each procedure was designated as simple, intermediate, or complex. Patient organ radiation doses were estimated using an anthropomorphic model. Dose to the interventional radiologist was estimated using ion chamber survey meters.</p><p><strong>Results: </strong>The average CT fluoroscopy time for technically simple cases was 47 s, 126 s for intermediate cases, and 264 s for complex cases. The relative risk of hematologic stomach and liver malignancy in patients undergoing this procedure was 1.003-1.074. The lifetime attributable risk of cancer ranged from 2 to 58, with the highest risk in younger patients for developing leukemia. The estimated radiation dose to the interventionalist without lead shielding was 390 mR (3.9 mGy) per year of cases.</p><p><strong>Conclusions: </strong>The radiation risk to the patient during CT fluoroscopy-guided percutaneous renal mass cryoablation is, as expected, related to procedure complexity. Quantification of patient organ radiation dose was estimated using an anthropomorphic model. This information, along with the associated relative risk of malignancy, may assist in evaluating risks of the procedure, particularly in younger patients. The radiation dose to the interventionist is low regardless of procedure complexity, but highlights the importance of lead shielding.</p>","PeriodicalId":7014,"journal":{"name":"Abdominal Imaging","volume":"40 7","pages":"2606-12"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00261-015-0456-2","citationCount":"7","resultStr":"{\"title\":\"Percutaneous cryoablation of renal masses under CT fluoroscopy: radiation doses to the patient and interventionalist.\",\"authors\":\"Jessica K Stewart,&nbsp;Christopher B Looney,&nbsp;Colin D Anderson-Evans,&nbsp;Greta I Toncheva,&nbsp;David R Sopko,&nbsp;Charles Y Kim,&nbsp;Terry T Yoshizumi,&nbsp;Rendon C Nelson\",\"doi\":\"10.1007/s00261-015-0456-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Computed tomographic (CT) fluoroscopy-guided percutaneous cryoablation is an effective therapeutic method used to treat focal renal masses. The purpose of this study is to quantify the radiation dose to the patient and interventional radiologist during percutaneous cryoablation of renal masses using CT fluoroscopic guidance.</p><p><strong>Methods: </strong>Over a 1-year period, the CT fluoroscopy time during percutaneous cryoablation of renal masses was recorded in 41 patients. The level of complexity of each procedure was designated as simple, intermediate, or complex. Patient organ radiation doses were estimated using an anthropomorphic model. Dose to the interventional radiologist was estimated using ion chamber survey meters.</p><p><strong>Results: </strong>The average CT fluoroscopy time for technically simple cases was 47 s, 126 s for intermediate cases, and 264 s for complex cases. The relative risk of hematologic stomach and liver malignancy in patients undergoing this procedure was 1.003-1.074. The lifetime attributable risk of cancer ranged from 2 to 58, with the highest risk in younger patients for developing leukemia. The estimated radiation dose to the interventionalist without lead shielding was 390 mR (3.9 mGy) per year of cases.</p><p><strong>Conclusions: </strong>The radiation risk to the patient during CT fluoroscopy-guided percutaneous renal mass cryoablation is, as expected, related to procedure complexity. Quantification of patient organ radiation dose was estimated using an anthropomorphic model. This information, along with the associated relative risk of malignancy, may assist in evaluating risks of the procedure, particularly in younger patients. The radiation dose to the interventionist is low regardless of procedure complexity, but highlights the importance of lead shielding.</p>\",\"PeriodicalId\":7014,\"journal\":{\"name\":\"Abdominal Imaging\",\"volume\":\"40 7\",\"pages\":\"2606-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s00261-015-0456-2\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Abdominal Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00261-015-0456-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Abdominal Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00261-015-0456-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

目的:CT透视引导下经皮冷冻消融治疗局灶性肾肿块是一种有效的治疗方法。本研究的目的是量化在CT透视引导下经皮肾肿块冷冻消融过程中对患者和介入放射科医生的辐射剂量。方法:记录41例经皮肾肿块冷冻消融术中CT透视时间。每个程序的复杂程度被指定为简单、中级或复杂。使用拟人模型估计患者器官辐射剂量。使用离子室测量仪估计介入放射科医生的剂量。结果:单纯病例CT透视平均时间为47 s,中度病例平均时间为126 s,复杂病例平均时间为264 s。接受该手术的患者发生胃和肝脏血液学恶性肿瘤的相对危险度为1.003-1.074。终生癌症归因风险从2到58不等,年轻患者患白血病的风险最高。在没有铅屏蔽的情况下,对介入医师的估计辐射剂量为每年390 mR (3.9 mGy)。结论:CT透视引导下经皮肾肿块冷冻消融对患者的辐射风险与手术复杂性有关。使用拟人模型估计患者器官辐射剂量的量化。这些信息,以及相关的恶性肿瘤的相对风险,可能有助于评估手术的风险,特别是在年轻患者中。无论手术的复杂程度如何,介入医生的辐射剂量都很低,但这突出了铅屏蔽的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Percutaneous cryoablation of renal masses under CT fluoroscopy: radiation doses to the patient and interventionalist.

Purpose: Computed tomographic (CT) fluoroscopy-guided percutaneous cryoablation is an effective therapeutic method used to treat focal renal masses. The purpose of this study is to quantify the radiation dose to the patient and interventional radiologist during percutaneous cryoablation of renal masses using CT fluoroscopic guidance.

Methods: Over a 1-year period, the CT fluoroscopy time during percutaneous cryoablation of renal masses was recorded in 41 patients. The level of complexity of each procedure was designated as simple, intermediate, or complex. Patient organ radiation doses were estimated using an anthropomorphic model. Dose to the interventional radiologist was estimated using ion chamber survey meters.

Results: The average CT fluoroscopy time for technically simple cases was 47 s, 126 s for intermediate cases, and 264 s for complex cases. The relative risk of hematologic stomach and liver malignancy in patients undergoing this procedure was 1.003-1.074. The lifetime attributable risk of cancer ranged from 2 to 58, with the highest risk in younger patients for developing leukemia. The estimated radiation dose to the interventionalist without lead shielding was 390 mR (3.9 mGy) per year of cases.

Conclusions: The radiation risk to the patient during CT fluoroscopy-guided percutaneous renal mass cryoablation is, as expected, related to procedure complexity. Quantification of patient organ radiation dose was estimated using an anthropomorphic model. This information, along with the associated relative risk of malignancy, may assist in evaluating risks of the procedure, particularly in younger patients. The radiation dose to the interventionist is low regardless of procedure complexity, but highlights the importance of lead shielding.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Abdominal Imaging
Abdominal Imaging 医学-核医学
自引率
0.00%
发文量
334
审稿时长
2 months
期刊最新文献
Magnetic resonance imaging of rectal cancer: staging and restaging evaluation. The wall-echo-shadow (WES) sign. Lowering radiation dose during dedicated colorectal cancer MDCT: comparison of low tube voltage and sinogram-affirmed iterative reconstruction at 80 kVp versus blended dual-energy images in a population of patients with low body mass index. Female perineal diseases: spectrum of imaging findings. Effect of radiologists' experience with an adaptive statistical iterative reconstruction algorithm on detection of hypervascular liver lesions and perception of image quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1