Rui Sun, Yanping Wang, Jie Zhang, Tijian Deng, Qiru Yi, Bei Yu, Mei Huang, Gang Li, Xiaoming Jiang
{"title":"微扫描同步辐射大视场高分辨率x射线成像技术。","authors":"Rui Sun, Yanping Wang, Jie Zhang, Tijian Deng, Qiru Yi, Bei Yu, Mei Huang, Gang Li, Xiaoming Jiang","doi":"10.1107/S1600577522007652","DOIUrl":null,"url":null,"abstract":"<p><p>In synchrotron radiation X-ray imaging, the imaging field of view and spatial resolution are mutually restricted, which makes it impossible to have both a large field of view and high resolution when carrying out experiments. Constructing an oversampled image through the micro-scanning method and using the deconvolution algorithm to eliminate the point spread function introduced by pixel overlap can increase the resolution under a fixed imaging field of view, thereby improving the ratio of the field of view to the spatial resolution. In this paper, numerical simulation and synchrotron radiation experiments are carried out with a different number of micro-scanning steps. In numerical simulation experiments only affected by the image pixel size, as the number of micro-scanning steps increases, the ability of the oversampled image with deconvolution to improve the resolution is stronger. The achievable resolution of the oversampled image with deconvolution is basically the same as that of the sample image. In the synchrotron radiation experiments, the resolution of the oversampled image with deconvolution in the 2 × 2 mode is significantly improved. However, as the number of micro-scanning steps increases, the resolution improvement is limited, or even no longer improved. Finally, by analyzing the results of numerical simulation and synchrotron radiation experiments, three factors (four other factors affecting the resolution besides the camera resolution, translational accuracy of micro-scanning, and the signal-to-noise ratio of projections) affecting the micro-scanning method are proposed and verified by experiments.</p>","PeriodicalId":17114,"journal":{"name":"Journal of Synchrotron Radiation","volume":"29 Pt 5","pages":"1241-1250"},"PeriodicalIF":2.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455207/pdf/","citationCount":"1","resultStr":"{\"title\":\"Synchrotron radiation X-ray imaging with large field of view and high resolution using micro-scanning method.\",\"authors\":\"Rui Sun, Yanping Wang, Jie Zhang, Tijian Deng, Qiru Yi, Bei Yu, Mei Huang, Gang Li, Xiaoming Jiang\",\"doi\":\"10.1107/S1600577522007652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In synchrotron radiation X-ray imaging, the imaging field of view and spatial resolution are mutually restricted, which makes it impossible to have both a large field of view and high resolution when carrying out experiments. Constructing an oversampled image through the micro-scanning method and using the deconvolution algorithm to eliminate the point spread function introduced by pixel overlap can increase the resolution under a fixed imaging field of view, thereby improving the ratio of the field of view to the spatial resolution. In this paper, numerical simulation and synchrotron radiation experiments are carried out with a different number of micro-scanning steps. In numerical simulation experiments only affected by the image pixel size, as the number of micro-scanning steps increases, the ability of the oversampled image with deconvolution to improve the resolution is stronger. The achievable resolution of the oversampled image with deconvolution is basically the same as that of the sample image. In the synchrotron radiation experiments, the resolution of the oversampled image with deconvolution in the 2 × 2 mode is significantly improved. However, as the number of micro-scanning steps increases, the resolution improvement is limited, or even no longer improved. Finally, by analyzing the results of numerical simulation and synchrotron radiation experiments, three factors (four other factors affecting the resolution besides the camera resolution, translational accuracy of micro-scanning, and the signal-to-noise ratio of projections) affecting the micro-scanning method are proposed and verified by experiments.</p>\",\"PeriodicalId\":17114,\"journal\":{\"name\":\"Journal of Synchrotron Radiation\",\"volume\":\"29 Pt 5\",\"pages\":\"1241-1250\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455207/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Synchrotron Radiation\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1107/S1600577522007652\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/8/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Synchrotron Radiation","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1107/S1600577522007652","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Synchrotron radiation X-ray imaging with large field of view and high resolution using micro-scanning method.
In synchrotron radiation X-ray imaging, the imaging field of view and spatial resolution are mutually restricted, which makes it impossible to have both a large field of view and high resolution when carrying out experiments. Constructing an oversampled image through the micro-scanning method and using the deconvolution algorithm to eliminate the point spread function introduced by pixel overlap can increase the resolution under a fixed imaging field of view, thereby improving the ratio of the field of view to the spatial resolution. In this paper, numerical simulation and synchrotron radiation experiments are carried out with a different number of micro-scanning steps. In numerical simulation experiments only affected by the image pixel size, as the number of micro-scanning steps increases, the ability of the oversampled image with deconvolution to improve the resolution is stronger. The achievable resolution of the oversampled image with deconvolution is basically the same as that of the sample image. In the synchrotron radiation experiments, the resolution of the oversampled image with deconvolution in the 2 × 2 mode is significantly improved. However, as the number of micro-scanning steps increases, the resolution improvement is limited, or even no longer improved. Finally, by analyzing the results of numerical simulation and synchrotron radiation experiments, three factors (four other factors affecting the resolution besides the camera resolution, translational accuracy of micro-scanning, and the signal-to-noise ratio of projections) affecting the micro-scanning method are proposed and verified by experiments.
期刊介绍:
Synchrotron radiation research is rapidly expanding with many new sources of radiation being created globally. Synchrotron radiation plays a leading role in pure science and in emerging technologies. The Journal of Synchrotron Radiation provides comprehensive coverage of the entire field of synchrotron radiation and free-electron laser research including instrumentation, theory, computing and scientific applications in areas such as biology, nanoscience and materials science. Rapid publication ensures an up-to-date information resource for scientists and engineers in the field.