圆锥角膜微型巩膜隐形眼镜模型的临床疗效预测。

IF 4.1 1区 医学 Q1 OPHTHALMOLOGY Eye and Vision Pub Date : 2022-10-06 DOI:10.1186/s40662-022-00310-5
Abdelkader Sidi Mohamed Hamida, García-Barchín Marta, Ruiz-Fortes Pedro, David P Piñero
{"title":"圆锥角膜微型巩膜隐形眼镜模型的临床疗效预测。","authors":"Abdelkader Sidi Mohamed Hamida,&nbsp;García-Barchín Marta,&nbsp;Ruiz-Fortes Pedro,&nbsp;David P Piñero","doi":"10.1186/s40662-022-00310-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate which factors are correlated with the visual improvement achieved with a specific model of scleral contact lens (SCL) in keratoconus (KC) eyes and to define a model to predict such improvement according to the pre-fitting data. In addition, the changes occurred with the fitting of a specific model of SCL during a period of 3 months in corneas with KC have been investigated.</p><p><strong>Methods: </strong>Longitudinal retrospective study including 30 eyes of 18 patients (age, 14-65 years) with KC fitted with the SCL ICD16.50 (Paragon Vision Sciences). Visual, refractive, corneal tomographic and ocular aberrometric changes were evaluated during a 3-month follow-up. Likewise, the characterization of the post-lens meniscus was performed by optical coherence tomography (OCT) with the measurement of central, nasal and temporal vaults.</p><p><strong>Results: </strong>The visual acuity increased significantly from a mean pre-fitting value with spectacles of 0.23 ± 0.07 logarithm of minimal angle of resolution (logMAR) to a mean value of 0.10 ± 0.04 logMAR after 1 month of SCL wear (P < 0.001). An improvement of 1 or more lines of visual acuity with the SCL occurred in 62.1% of the eyes. A significant decrease in central, nasal, and temporal vault was observed after 1 month of SCL wear (P ≤ 0.046). Likewise, there was a significant difference between nasal and temporal vaults during the first month of SCL use (P = 0.008). Furthermore, a significant reduction of ocular high order (P = 0.028) and primary coma root mean square (P = 0.018) was found with the SCL. A predicting linear equation of the change in visual acuity achievable with the SCL was obtained (P < 0.001, R<sup>2</sup> = 0.878) considering the pre-fitting spectacle corrected distance visual acuity, and the power and sagittal lens of SCL.</p><p><strong>Conclusions: </strong>The scleral contact lens evaluated provides an efficacious visual rehabilitation in KC due to the improvement of visual acuity and the correction of low and high-order ocular aberrations. This visual acuity improvement can be predicted from some pre-fitting variables.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2022-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536044/pdf/","citationCount":"0","resultStr":"{\"title\":\"Characterization and prediction of the clinical result with a specific model of mini-scleral contact lens in corneas with keratoconus.\",\"authors\":\"Abdelkader Sidi Mohamed Hamida,&nbsp;García-Barchín Marta,&nbsp;Ruiz-Fortes Pedro,&nbsp;David P Piñero\",\"doi\":\"10.1186/s40662-022-00310-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To investigate which factors are correlated with the visual improvement achieved with a specific model of scleral contact lens (SCL) in keratoconus (KC) eyes and to define a model to predict such improvement according to the pre-fitting data. In addition, the changes occurred with the fitting of a specific model of SCL during a period of 3 months in corneas with KC have been investigated.</p><p><strong>Methods: </strong>Longitudinal retrospective study including 30 eyes of 18 patients (age, 14-65 years) with KC fitted with the SCL ICD16.50 (Paragon Vision Sciences). Visual, refractive, corneal tomographic and ocular aberrometric changes were evaluated during a 3-month follow-up. Likewise, the characterization of the post-lens meniscus was performed by optical coherence tomography (OCT) with the measurement of central, nasal and temporal vaults.</p><p><strong>Results: </strong>The visual acuity increased significantly from a mean pre-fitting value with spectacles of 0.23 ± 0.07 logarithm of minimal angle of resolution (logMAR) to a mean value of 0.10 ± 0.04 logMAR after 1 month of SCL wear (P < 0.001). An improvement of 1 or more lines of visual acuity with the SCL occurred in 62.1% of the eyes. A significant decrease in central, nasal, and temporal vault was observed after 1 month of SCL wear (P ≤ 0.046). Likewise, there was a significant difference between nasal and temporal vaults during the first month of SCL use (P = 0.008). Furthermore, a significant reduction of ocular high order (P = 0.028) and primary coma root mean square (P = 0.018) was found with the SCL. A predicting linear equation of the change in visual acuity achievable with the SCL was obtained (P < 0.001, R<sup>2</sup> = 0.878) considering the pre-fitting spectacle corrected distance visual acuity, and the power and sagittal lens of SCL.</p><p><strong>Conclusions: </strong>The scleral contact lens evaluated provides an efficacious visual rehabilitation in KC due to the improvement of visual acuity and the correction of low and high-order ocular aberrations. This visual acuity improvement can be predicted from some pre-fitting variables.</p>\",\"PeriodicalId\":12194,\"journal\":{\"name\":\"Eye and Vision\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2022-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536044/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and Vision\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-022-00310-5\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-022-00310-5","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:探讨特定模型巩膜接触镜(SCL)对圆锥角膜(KC)眼视力改善的影响因素,并根据预拟合数据建立预测模型。此外,我们还研究了KC角膜在3个月的时间里,在特定的SCL模型的拟合下发生的变化。方法:对18例30眼,年龄14 ~ 65岁的KC患者进行纵向回顾性研究,该患者安装了SCL ICD16.50 (Paragon Vision Sciences)。在3个月的随访中评估视力、屈光、角膜层析成像和眼像差的变化。同样,通过光学相干断层扫描(OCT)测量中央、鼻和颞穹窿,对晶状体后半月板进行表征。结果:考虑到预配眼镜矫正距离视力、SCL的度数和矢状晶状体,配戴SCL 1个月后,视力从配戴前的平均0.23±0.07对数最小分辨角(logMAR)显著提高到0.10±0.04对数分辨角(logMAR) (P = 0.878)。结论:巩膜接触镜可改善KC患者的视力,矫正低阶和高阶眼像差,具有良好的视力康复效果。这种视力的改善可以通过一些预拟合变量来预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterization and prediction of the clinical result with a specific model of mini-scleral contact lens in corneas with keratoconus.

Background: To investigate which factors are correlated with the visual improvement achieved with a specific model of scleral contact lens (SCL) in keratoconus (KC) eyes and to define a model to predict such improvement according to the pre-fitting data. In addition, the changes occurred with the fitting of a specific model of SCL during a period of 3 months in corneas with KC have been investigated.

Methods: Longitudinal retrospective study including 30 eyes of 18 patients (age, 14-65 years) with KC fitted with the SCL ICD16.50 (Paragon Vision Sciences). Visual, refractive, corneal tomographic and ocular aberrometric changes were evaluated during a 3-month follow-up. Likewise, the characterization of the post-lens meniscus was performed by optical coherence tomography (OCT) with the measurement of central, nasal and temporal vaults.

Results: The visual acuity increased significantly from a mean pre-fitting value with spectacles of 0.23 ± 0.07 logarithm of minimal angle of resolution (logMAR) to a mean value of 0.10 ± 0.04 logMAR after 1 month of SCL wear (P < 0.001). An improvement of 1 or more lines of visual acuity with the SCL occurred in 62.1% of the eyes. A significant decrease in central, nasal, and temporal vault was observed after 1 month of SCL wear (P ≤ 0.046). Likewise, there was a significant difference between nasal and temporal vaults during the first month of SCL use (P = 0.008). Furthermore, a significant reduction of ocular high order (P = 0.028) and primary coma root mean square (P = 0.018) was found with the SCL. A predicting linear equation of the change in visual acuity achievable with the SCL was obtained (P < 0.001, R2 = 0.878) considering the pre-fitting spectacle corrected distance visual acuity, and the power and sagittal lens of SCL.

Conclusions: The scleral contact lens evaluated provides an efficacious visual rehabilitation in KC due to the improvement of visual acuity and the correction of low and high-order ocular aberrations. This visual acuity improvement can be predicted from some pre-fitting variables.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Eye and Vision
Eye and Vision OPHTHALMOLOGY-
CiteScore
8.60
自引率
2.40%
发文量
89
审稿时长
15 weeks
期刊介绍: Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.
期刊最新文献
An L-type calcium channel blocker nimodipine exerts anti-fibrotic effects by attenuating TGF-β1 induced calcium response in an in vitro model of thyroid eye disease. Efficacy of orthokeratology lens with the modified small treatment zone on myopia progression and visual quality: a randomized clinical trial. Nominal and achieved stromal ablation depth after myopic transepithelial photorefractive keratectomy: implications for residual stromal thickness calculation. Quantitative analysis of peripapillary capillary volume using dense B-scan OCT angiography in normal and diabetic retina. Correction: Prognostic potentials of AI in ophthalmology: systemic disease forecasting via retinal imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1