{"title":"1型糖尿病患者传感器增强泵治疗(Minimed 640G系统)联合远程医疗随访的长期疗效:一项现实生活研究","authors":"Léonie Makuété Notemi ,&nbsp;Lamia Amoura ,&nbsp;Fatéma Fall Mostaine ,&nbsp;Laurent Meyer ,&nbsp;Dominique Paris ,&nbsp;Samy Talha ,&nbsp;Julien Pottecher ,&nbsp;Laurence Kessler","doi":"10.1016/j.jcte.2022.100306","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Evaluate the efficacy of a new modality of insulin therapy associating both the sensor-augmented pump therapy with predictive low-glucose management (SAP-PLGM) and a telemedicine follow-up in patients with Type 1 diabetes (T1D) in a real-life setting.</p></div><div><h3>Methods</h3><p>T1D adults under Minimed 640G system with a telemedicine follow-up for glucose management were included in a retrospective study. The primary endpoint was HbA1c while continuous glucose monitoring parameters (CGM) and treatment compliance were the secondary endpoints. These parameters were analyzed according to the therapeutic indication, HbA1c ≥ 8 % (Group<!--> <!-->A) or severe hypoglycemic events (Group<!--> <!-->B) and in patients switched to SAP-PLGM therapy.</p></div><div><h3>Results</h3><p>62<!--> <!-->patients were analyzed with a 28 ± 12 months of follow-up. In Group<!--> <!-->A, HbA1c decreased from 8.3 ± 0.4 % to 7.7 ± 0.7 % (<em>p</em> &lt; 0.05) and to 7.9 ± 0.3 % (<em>p</em> &lt; 0.05) after 2 and 3 years, respectively. In patients switched to SAP-PLGM therapy, HbA1c decreased from 7.7 ± 0.7 % to 7.2 ± 0.8 % (<em>p</em> &lt; 0.05) at 2 years. After 6 months, the time-below-range (&lt;70 mg/dL) decreased from 2.1 % [0.6–4] to 1.1 % [0.3–2.6] (<em>p</em> &lt; 0.05). Severe hypoglycemic events decreased from 1.62 to 0.5<!--> <!-->events/patient/year in Group<!--> <!-->B (p &lt; 0.05). At 3 years, treatment compliance was 92 % [70–97] in the total population.</p></div><div><h3>Conclusions</h3><p>Long-term real-life treatment with the SAP-PLGM therapy combined with telemedicine was associated with improved glycemic control in T1D, along with high treatment compliance.</p></div>","PeriodicalId":46328,"journal":{"name":"Journal of Clinical and Translational Endocrinology","volume":"30 ","pages":"Article 100306"},"PeriodicalIF":3.3000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/02/d9/main.PMC9550647.pdf","citationCount":"0","resultStr":"{\"title\":\"Long-term efficacy of sensor-augmented pump therapy (Minimed 640G system) combined with a telemedicine follow-up in patients with type 1 diabetes: A real life study\",\"authors\":\"Léonie Makuété Notemi ,&nbsp;Lamia Amoura ,&nbsp;Fatéma Fall Mostaine ,&nbsp;Laurent Meyer ,&nbsp;Dominique Paris ,&nbsp;Samy Talha ,&nbsp;Julien Pottecher ,&nbsp;Laurence Kessler\",\"doi\":\"10.1016/j.jcte.2022.100306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>Evaluate the efficacy of a new modality of insulin therapy associating both the sensor-augmented pump therapy with predictive low-glucose management (SAP-PLGM) and a telemedicine follow-up in patients with Type 1 diabetes (T1D) in a real-life setting.</p></div><div><h3>Methods</h3><p>T1D adults under Minimed 640G system with a telemedicine follow-up for glucose management were included in a retrospective study. The primary endpoint was HbA1c while continuous glucose monitoring parameters (CGM) and treatment compliance were the secondary endpoints. These parameters were analyzed according to the therapeutic indication, HbA1c ≥ 8 % (Group<!--> <!-->A) or severe hypoglycemic events (Group<!--> <!-->B) and in patients switched to SAP-PLGM therapy.</p></div><div><h3>Results</h3><p>62<!--> <!-->patients were analyzed with a 28 ± 12 months of follow-up. In Group<!--> <!-->A, HbA1c decreased from 8.3 ± 0.4 % to 7.7 ± 0.7 % (<em>p</em> &lt; 0.05) and to 7.9 ± 0.3 % (<em>p</em> &lt; 0.05) after 2 and 3 years, respectively. In patients switched to SAP-PLGM therapy, HbA1c decreased from 7.7 ± 0.7 % to 7.2 ± 0.8 % (<em>p</em> &lt; 0.05) at 2 years. After 6 months, the time-below-range (&lt;70 mg/dL) decreased from 2.1 % [0.6–4] to 1.1 % [0.3–2.6] (<em>p</em> &lt; 0.05). Severe hypoglycemic events decreased from 1.62 to 0.5<!--> <!-->events/patient/year in Group<!--> <!-->B (p &lt; 0.05). At 3 years, treatment compliance was 92 % [70–97] in the total population.</p></div><div><h3>Conclusions</h3><p>Long-term real-life treatment with the SAP-PLGM therapy combined with telemedicine was associated with improved glycemic control in T1D, along with high treatment compliance.</p></div>\",\"PeriodicalId\":46328,\"journal\":{\"name\":\"Journal of Clinical and Translational Endocrinology\",\"volume\":\"30 \",\"pages\":\"Article 100306\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/02/d9/main.PMC9550647.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Translational Endocrinology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S221462372200014X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/10/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Translational Endocrinology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221462372200014X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

目的评估一种新的胰岛素治疗模式,将传感器增强泵治疗与预测低血糖管理(SAP-PLGM)和远程医疗随访相结合,在现实生活中治疗1型糖尿病(T1D)患者。方法回顾性研究采用minimem640g系统并进行远程医疗随访的成人血糖管理。主要终点是HbA1c,而连续血糖监测参数(CGM)和治疗依从性是次要终点。根据治疗指征,HbA1c≥8% (A组)或严重低血糖事件(B组)以及切换到SAP-PLGM治疗的患者,对这些参数进行分析。结果对62例患者进行分析,随访28±12个月。在A组中,糖化血红蛋白下降从8.3±0.4%到7.7±0.7% (p & lt;0.05)和7.9±0.3% (p <2、3年后分别为0.05)。在改用SAP-PLGM治疗的患者中,HbA1c从7.7±0.7%降至7.2±0.8% (p <0.05)。6个月后,低于时限(70 mg/dL)从2.1%[0.6-4]降至1.1% [0.3-2.6](p <0.05)。B组严重低血糖事件从1.62例/例/年降至0.5例/例/年(p <0.05)。3年时,治疗依从性为92%[70-97]。结论SAP-PLGM联合远程医疗的长期现实治疗可改善T1D患者的血糖控制,且治疗依从性高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Long-term efficacy of sensor-augmented pump therapy (Minimed 640G system) combined with a telemedicine follow-up in patients with type 1 diabetes: A real life study

Objective

Evaluate the efficacy of a new modality of insulin therapy associating both the sensor-augmented pump therapy with predictive low-glucose management (SAP-PLGM) and a telemedicine follow-up in patients with Type 1 diabetes (T1D) in a real-life setting.

Methods

T1D adults under Minimed 640G system with a telemedicine follow-up for glucose management were included in a retrospective study. The primary endpoint was HbA1c while continuous glucose monitoring parameters (CGM) and treatment compliance were the secondary endpoints. These parameters were analyzed according to the therapeutic indication, HbA1c ≥ 8 % (Group A) or severe hypoglycemic events (Group B) and in patients switched to SAP-PLGM therapy.

Results

62 patients were analyzed with a 28 ± 12 months of follow-up. In Group A, HbA1c decreased from 8.3 ± 0.4 % to 7.7 ± 0.7 % (p < 0.05) and to 7.9 ± 0.3 % (p < 0.05) after 2 and 3 years, respectively. In patients switched to SAP-PLGM therapy, HbA1c decreased from 7.7 ± 0.7 % to 7.2 ± 0.8 % (p < 0.05) at 2 years. After 6 months, the time-below-range (<70 mg/dL) decreased from 2.1 % [0.6–4] to 1.1 % [0.3–2.6] (p < 0.05). Severe hypoglycemic events decreased from 1.62 to 0.5 events/patient/year in Group B (p < 0.05). At 3 years, treatment compliance was 92 % [70–97] in the total population.

Conclusions

Long-term real-life treatment with the SAP-PLGM therapy combined with telemedicine was associated with improved glycemic control in T1D, along with high treatment compliance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
0.00%
发文量
24
审稿时长
16 weeks
期刊最新文献
Utilization and clinical characteristics of patients with type 2 diabetes and chronic kidney disease prescribed finerenone in the United States Changes in uric acid metabolism and associated plasma proteomics during sex hormone therapy Lipid metabolic dysregulation in diabetic kidney disease: mechanisms, cellular impact, and therapeutic strategies A functional medicine approach to diabetes control and quality of life: an open-label randomized pilot study Effect of temperature and preservative selection on C-peptide degradation in randomly voided urine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1