{"title":"细胞外囊泡的流式细胞术:潜力、缺陷和前景","authors":"John P. Nolan","doi":"10.1002/0471142956.cy1314s73","DOIUrl":null,"url":null,"abstract":"<p>Evidence suggests that extracellular vesicles (EVs) can play roles in physiology and pathology, providing impetus to explore their use as diagnostic and therapeutic targets. However, EVs are also small, heterogeneous, and difficult to measure, and so this potential has not yet been realized. The development of improved approaches to EV detection and characterization will be critical to further understanding their roles in physiology and disease. Flow cytometry has been a popular tool for measuring cell-derived EVs, but has often been used in an uncritical manner in which fundamental principles and limitations of the instrument are ignored. Recent efforts to standardize procedures and document the effects of different methodologies have helped to address this shortcoming, but much work remains. In this paper, I address some of the instrument, reagent, and analysis considerations relevant to measurement of individual EVs in flow, with the aim of clarifying a path to quantitative and standardized measurement of these interesting and potentially important biological nanoparticles. © 2015 by John Wiley &amp; Sons, Inc.</p>","PeriodicalId":11020,"journal":{"name":"Current Protocols in Cytometry","volume":"73 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/0471142956.cy1314s73","citationCount":"90","resultStr":"{\"title\":\"Flow Cytometry of Extracellular Vesicles: Potential, Pitfalls, and Prospects\",\"authors\":\"John P. Nolan\",\"doi\":\"10.1002/0471142956.cy1314s73\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Evidence suggests that extracellular vesicles (EVs) can play roles in physiology and pathology, providing impetus to explore their use as diagnostic and therapeutic targets. However, EVs are also small, heterogeneous, and difficult to measure, and so this potential has not yet been realized. The development of improved approaches to EV detection and characterization will be critical to further understanding their roles in physiology and disease. Flow cytometry has been a popular tool for measuring cell-derived EVs, but has often been used in an uncritical manner in which fundamental principles and limitations of the instrument are ignored. Recent efforts to standardize procedures and document the effects of different methodologies have helped to address this shortcoming, but much work remains. In this paper, I address some of the instrument, reagent, and analysis considerations relevant to measurement of individual EVs in flow, with the aim of clarifying a path to quantitative and standardized measurement of these interesting and potentially important biological nanoparticles. © 2015 by John Wiley &amp; Sons, Inc.</p>\",\"PeriodicalId\":11020,\"journal\":{\"name\":\"Current Protocols in Cytometry\",\"volume\":\"73 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/0471142956.cy1314s73\",\"citationCount\":\"90\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Protocols in Cytometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/0471142956.cy1314s73\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Protocols in Cytometry","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/0471142956.cy1314s73","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 90

摘要

有证据表明,细胞外囊泡(EVs)可以在生理和病理中发挥作用,为探索其作为诊断和治疗靶点提供了动力。然而,电动汽车体积小、异构、难以测量,因此这种潜力尚未实现。改进EV检测和表征方法的发展对于进一步了解其在生理和疾病中的作用至关重要。流式细胞术一直是一种流行的工具,用于测量细胞源性ev,但经常被用于不加批判的方式,其中忽略了仪器的基本原理和局限性。最近标准化程序和记录不同方法的效果的努力有助于解决这一缺点,但仍有许多工作要做。在本文中,我讨论了一些仪器、试剂和分析方面的问题,这些问题与测量流动中的单个ev有关,目的是阐明对这些有趣的、潜在重要的生物纳米颗粒进行定量和标准化测量的途径。©2015 by John Wiley &儿子,Inc。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Flow Cytometry of Extracellular Vesicles: Potential, Pitfalls, and Prospects

Evidence suggests that extracellular vesicles (EVs) can play roles in physiology and pathology, providing impetus to explore their use as diagnostic and therapeutic targets. However, EVs are also small, heterogeneous, and difficult to measure, and so this potential has not yet been realized. The development of improved approaches to EV detection and characterization will be critical to further understanding their roles in physiology and disease. Flow cytometry has been a popular tool for measuring cell-derived EVs, but has often been used in an uncritical manner in which fundamental principles and limitations of the instrument are ignored. Recent efforts to standardize procedures and document the effects of different methodologies have helped to address this shortcoming, but much work remains. In this paper, I address some of the instrument, reagent, and analysis considerations relevant to measurement of individual EVs in flow, with the aim of clarifying a path to quantitative and standardized measurement of these interesting and potentially important biological nanoparticles. © 2015 by John Wiley & Sons, Inc.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Protocols in Cytometry
Current Protocols in Cytometry Health Professions-Medical Laboratory Technology
自引率
0.00%
发文量
0
期刊介绍: Published in affiliation with the International Society for Advancement of Cytometry, Current Protocols in Cytometry is a "best practices" collection that distills and organizes the absolute latest techniques from the top cytometry labs and specialists worldwide. It is the most complete set of peer-reviewed protocols for flow and image cytometry available.
期刊最新文献
Issue Information Detection and Sorting of Extracellular Vesicles and Viruses Using nanoFACS Live Imaging of the Lung Small Particle Fluorescence and Light Scatter Calibration Using FCMPASS Software. Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1