即刻加载两个(固定在2上)与四个(固定在4上)种植体,采用无瓣技术支持下颌交叉弓固定假体:一项为期3年的随机对照试验结果。

Q1 Dentistry European Journal of Oral Implantology Pub Date : 2017-01-01
Gioacchino Cannizzaro, Pietro Felice, Enrico Gherlone, Carlo Barausse, Vittorio Ferri, Michele Leone, Anna Trullenque-Eriksson, Marco Esposito
{"title":"即刻加载两个(固定在2上)与四个(固定在4上)种植体,采用无瓣技术支持下颌交叉弓固定假体:一项为期3年的随机对照试验结果。","authors":"Gioacchino Cannizzaro,&nbsp;Pietro Felice,&nbsp;Enrico Gherlone,&nbsp;Carlo Barausse,&nbsp;Vittorio Ferri,&nbsp;Michele Leone,&nbsp;Anna Trullenque-Eriksson,&nbsp;Marco Esposito","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the outcome of two vs four implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.</p><p><strong>Materials and methods: </strong>A total of 60 patients from two different centres were randomised: 30 to the fixed-on-2 group and 30 to the fixed-on-4 group according to a parallel group design. To be immediately loaded implants had to be inserted with a minimum torque of 40 Newton/cm (Ncm). Outcome measures were prosthesis and implant failures, complications, and marginal bone level changes.</p><p><strong>Results: </strong>Flaps were raised in 18 patients. Two implants in two patients did not reach the planned insertion torque and were replaced immediately by larger diameter ones. Three years after loading, two patients dropped out from the fixed-on-2 group and one from the fixed-on-4 group. No implant failure or prosthetic failure occurred. A total of 12 fixed-on-2 patients were affected by one complication each vs 13 fixed-on-4 patients. There were no statistically significant differences for complications between groups (difference in proportion = -0.03; 95% CI -29 to 0.22; P [Fisher's exact test] =1.000). There were no statistically significant differences for marginal peri-implant bone loss between the two groups (mean difference = 0.14; CI 95% -0.17 to 0.45; P [ANCOVA] = 0.356), with both groups losing marginal bone in a statistically significant way (1.70 mm for fixed-on-2 implants and 1.56 mm for fixed-on-4 implants). There were statistically significant differences between the two centres, with more bone being lost for the Bologna centre (2.18 vs 1.13 mm; P (ANCOVA) < 0.001).</p><p><strong>Conclusions: </strong>Up to 3 years after loading, these preliminary results suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only two dental implants. Longer follow-ups (about 10 years) are needed to properly evaluate this therapeutic option. Conflict of interest statement: This study was completely self-financed and no funding from the implant manufacturers has been sought or obtained, not even in the form of free materials.</p>","PeriodicalId":49259,"journal":{"name":"European Journal of Oral Implantology","volume":"10 2","pages":"133-145"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Immediate loading of two (fixed-on-2) vs four (fixed-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: 3-year results from a pilot randomised controlled trial.\",\"authors\":\"Gioacchino Cannizzaro,&nbsp;Pietro Felice,&nbsp;Enrico Gherlone,&nbsp;Carlo Barausse,&nbsp;Vittorio Ferri,&nbsp;Michele Leone,&nbsp;Anna Trullenque-Eriksson,&nbsp;Marco Esposito\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the outcome of two vs four implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.</p><p><strong>Materials and methods: </strong>A total of 60 patients from two different centres were randomised: 30 to the fixed-on-2 group and 30 to the fixed-on-4 group according to a parallel group design. To be immediately loaded implants had to be inserted with a minimum torque of 40 Newton/cm (Ncm). Outcome measures were prosthesis and implant failures, complications, and marginal bone level changes.</p><p><strong>Results: </strong>Flaps were raised in 18 patients. Two implants in two patients did not reach the planned insertion torque and were replaced immediately by larger diameter ones. Three years after loading, two patients dropped out from the fixed-on-2 group and one from the fixed-on-4 group. No implant failure or prosthetic failure occurred. A total of 12 fixed-on-2 patients were affected by one complication each vs 13 fixed-on-4 patients. There were no statistically significant differences for complications between groups (difference in proportion = -0.03; 95% CI -29 to 0.22; P [Fisher's exact test] =1.000). There were no statistically significant differences for marginal peri-implant bone loss between the two groups (mean difference = 0.14; CI 95% -0.17 to 0.45; P [ANCOVA] = 0.356), with both groups losing marginal bone in a statistically significant way (1.70 mm for fixed-on-2 implants and 1.56 mm for fixed-on-4 implants). There were statistically significant differences between the two centres, with more bone being lost for the Bologna centre (2.18 vs 1.13 mm; P (ANCOVA) < 0.001).</p><p><strong>Conclusions: </strong>Up to 3 years after loading, these preliminary results suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only two dental implants. Longer follow-ups (about 10 years) are needed to properly evaluate this therapeutic option. Conflict of interest statement: This study was completely self-financed and no funding from the implant manufacturers has been sought or obtained, not even in the form of free materials.</p>\",\"PeriodicalId\":49259,\"journal\":{\"name\":\"European Journal of Oral Implantology\",\"volume\":\"10 2\",\"pages\":\"133-145\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Oral Implantology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Implantology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价在全无牙下颌骨无瓣放置2个种植体和4个种植体并立即使用金属-树脂螺钉保留的交叉弓修复体的效果。材料和方法:根据平行组设计,来自两个不同中心的60例患者被随机分组:30例为固定-2组,30例为固定-4组。要立即加载植入物,必须以最小扭矩40牛顿/厘米(Ncm)插入植入物。结果测量假体和种植体失败、并发症和边缘骨水平变化。结果:18例皮瓣成活。两名患者的两个植入物没有达到计划的插入扭矩,并立即更换了更大直径的植入物。加载三年后,两名患者从固定-2组退出,一名从固定-4组退出。无种植体失效或假体失效。共有12例固定on-2患者出现1个并发症,而固定on-4患者出现13个并发症。两组间并发症发生率差异无统计学意义(比例差异= -0.03;95% CI -29至0.22;P[费雪精确检验]=1.000)。两组种植体周缘骨丢失差异无统计学意义(平均差异= 0.14;CI 95% -0.17 ~ 0.45;P [ANCOVA] = 0.356),两组边缘骨丢失均有统计学意义(固定-2种植体1.70 mm,固定-4种植体1.56 mm)。两个中心之间有统计学上的显著差异,博洛尼亚中心的骨丢失更多(2.18 vs 1.13 mm;P (ANCOVA)结论:加载后3年,这些初步结果表明立即加载的下颌交叉弓固定假体可以仅由两个种植体支撑。需要更长的随访(约10年)来正确评估这种治疗选择。利益冲突声明:本研究完全自筹资金,没有从种植体制造商那里寻求或获得资金,甚至没有以免费材料的形式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Immediate loading of two (fixed-on-2) vs four (fixed-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: 3-year results from a pilot randomised controlled trial.

Purpose: To evaluate the outcome of two vs four implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.

Materials and methods: A total of 60 patients from two different centres were randomised: 30 to the fixed-on-2 group and 30 to the fixed-on-4 group according to a parallel group design. To be immediately loaded implants had to be inserted with a minimum torque of 40 Newton/cm (Ncm). Outcome measures were prosthesis and implant failures, complications, and marginal bone level changes.

Results: Flaps were raised in 18 patients. Two implants in two patients did not reach the planned insertion torque and were replaced immediately by larger diameter ones. Three years after loading, two patients dropped out from the fixed-on-2 group and one from the fixed-on-4 group. No implant failure or prosthetic failure occurred. A total of 12 fixed-on-2 patients were affected by one complication each vs 13 fixed-on-4 patients. There were no statistically significant differences for complications between groups (difference in proportion = -0.03; 95% CI -29 to 0.22; P [Fisher's exact test] =1.000). There were no statistically significant differences for marginal peri-implant bone loss between the two groups (mean difference = 0.14; CI 95% -0.17 to 0.45; P [ANCOVA] = 0.356), with both groups losing marginal bone in a statistically significant way (1.70 mm for fixed-on-2 implants and 1.56 mm for fixed-on-4 implants). There were statistically significant differences between the two centres, with more bone being lost for the Bologna centre (2.18 vs 1.13 mm; P (ANCOVA) < 0.001).

Conclusions: Up to 3 years after loading, these preliminary results suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only two dental implants. Longer follow-ups (about 10 years) are needed to properly evaluate this therapeutic option. Conflict of interest statement: This study was completely self-financed and no funding from the implant manufacturers has been sought or obtained, not even in the form of free materials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Oral Implantology
European Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.35
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Immediate loading of fixed prostheses in fully edentulous jaws - 1-year follow-up from a single-cohort retrospective study. Research in focus. Dental implants with internal versus external connections: 1-year post-loading results from a pragmatic multicenter randomised controlled trial. Research in focus. Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1