种植支撑全轮廓氧化锆与金属陶瓷固定局部义齿的疲劳断裂强度。

Fariborz Vafaee, Farnaz Firouz, Masoumeh Khoshhal, Amirarsalan Hooshyarfard, Armaghan Shahbazi, Ghodratollah Roshanaei
{"title":"种植支撑全轮廓氧化锆与金属陶瓷固定局部义齿的疲劳断裂强度。","authors":"Fariborz Vafaee,&nbsp;Farnaz Firouz,&nbsp;Masoumeh Khoshhal,&nbsp;Amirarsalan Hooshyarfard,&nbsp;Armaghan Shahbazi,&nbsp;Ghodratollah Roshanaei","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Zirconia restorations have been suggested as a more durable and more appealing alternative to metal restorations. However, their mechanical properties may be negatively affected by fatigue due to superficial stresses or low temperature degradation. This study aimed to assess the fatigue fracture strength of three-unit implant-supported full contour zirconia and pre-sintered cobalt-chromium (Co-Cr) alloy posterior fixed partial dentures (FPDs).</p><p><strong>Materials and methods: </strong>In this in-vitro experimental study, 28 posterior three-unit implant-supported FPDs were fabricated of full contour zirconia and pre-sintered Co-Cr alloy, and were cemented on implant abutments. To simulate the oral environment, FPDs were subjected to 10,000 thermal cycles between 5-55°C for 30 seconds, and were then transferred to a chewing simulator (100,000 cycles, 50 N, 0.5 Hz). Afterwards, fatigue fracture strength was measured using a universal testing machine. Data were analyzed by Mann-Whitney U test.</p><p><strong>Results: </strong>The mean and standard deviation of fracture strength were 2108.6±440.1 N in full contour zirconia, and 3499.9±1106.5 N in pre-sintered Co-Cr alloy. According to Mann-Whitney U test, the difference in this respect was statistically significant between the two groups (P=0.007).</p><p><strong>Conclusions: </strong>Since the fracture strength values obtained in the two groups were significantly higher than the maximum mean masticatory load in the oral environment, both materials can be used for fabrication of posterior three-unit FPDs, depending on the esthetic demands of patients.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5694850/pdf/","citationCount":"0","resultStr":"{\"title\":\"Fatigue Fracture Strength of Implant-Supported Full Contour Zirconia and Metal Ceramic Fixed Partial Dentures.\",\"authors\":\"Fariborz Vafaee,&nbsp;Farnaz Firouz,&nbsp;Masoumeh Khoshhal,&nbsp;Amirarsalan Hooshyarfard,&nbsp;Armaghan Shahbazi,&nbsp;Ghodratollah Roshanaei\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Zirconia restorations have been suggested as a more durable and more appealing alternative to metal restorations. However, their mechanical properties may be negatively affected by fatigue due to superficial stresses or low temperature degradation. This study aimed to assess the fatigue fracture strength of three-unit implant-supported full contour zirconia and pre-sintered cobalt-chromium (Co-Cr) alloy posterior fixed partial dentures (FPDs).</p><p><strong>Materials and methods: </strong>In this in-vitro experimental study, 28 posterior three-unit implant-supported FPDs were fabricated of full contour zirconia and pre-sintered Co-Cr alloy, and were cemented on implant abutments. To simulate the oral environment, FPDs were subjected to 10,000 thermal cycles between 5-55°C for 30 seconds, and were then transferred to a chewing simulator (100,000 cycles, 50 N, 0.5 Hz). Afterwards, fatigue fracture strength was measured using a universal testing machine. Data were analyzed by Mann-Whitney U test.</p><p><strong>Results: </strong>The mean and standard deviation of fracture strength were 2108.6±440.1 N in full contour zirconia, and 3499.9±1106.5 N in pre-sintered Co-Cr alloy. According to Mann-Whitney U test, the difference in this respect was statistically significant between the two groups (P=0.007).</p><p><strong>Conclusions: </strong>Since the fracture strength values obtained in the two groups were significantly higher than the maximum mean masticatory load in the oral environment, both materials can be used for fabrication of posterior three-unit FPDs, depending on the esthetic demands of patients.</p>\",\"PeriodicalId\":30286,\"journal\":{\"name\":\"Journal of Dentistry of Tehran University of Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5694850/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dentistry of Tehran University of Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:氧化锆修复体被认为是一种比金属修复体更耐用、更有吸引力的替代品。然而,由于表面应力或低温退化,它们的机械性能可能受到疲劳的负面影响。本研究旨在评估三单元种植支撑全轮廓氧化锆和预烧结钴铬合金(Co-Cr)后牙固定局部义齿(fpd)的疲劳断裂强度。材料与方法:本实验采用全轮廓氧化锆和预烧结Co-Cr合金制备28个后路三单元种植体支撑fpd,并将其粘接在种植体基牙上。为了模拟口腔环境,fpd在5-55°C之间进行10,000次热循环,持续30秒,然后转移到咀嚼模拟器(100,000次循环,50 N, 0.5 Hz)。然后,使用万能试验机测量疲劳断裂强度。数据分析采用Mann-Whitney U检验。结果:全轮廓氧化锆的断裂强度均值和标准差为2108.6±440.1 N,预烧结Co-Cr合金的断裂强度均值和标准差为3499.9±1106.5 N。根据Mann-Whitney U检验,两组在这方面的差异有统计学意义(P=0.007)。结论:由于两组获得的断裂强度值均显著高于口腔环境下的最大平均咀嚼负荷,因此根据患者的审美需求,两种材料均可用于制作后置三单元fpd。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fatigue Fracture Strength of Implant-Supported Full Contour Zirconia and Metal Ceramic Fixed Partial Dentures.

Objectives: Zirconia restorations have been suggested as a more durable and more appealing alternative to metal restorations. However, their mechanical properties may be negatively affected by fatigue due to superficial stresses or low temperature degradation. This study aimed to assess the fatigue fracture strength of three-unit implant-supported full contour zirconia and pre-sintered cobalt-chromium (Co-Cr) alloy posterior fixed partial dentures (FPDs).

Materials and methods: In this in-vitro experimental study, 28 posterior three-unit implant-supported FPDs were fabricated of full contour zirconia and pre-sintered Co-Cr alloy, and were cemented on implant abutments. To simulate the oral environment, FPDs were subjected to 10,000 thermal cycles between 5-55°C for 30 seconds, and were then transferred to a chewing simulator (100,000 cycles, 50 N, 0.5 Hz). Afterwards, fatigue fracture strength was measured using a universal testing machine. Data were analyzed by Mann-Whitney U test.

Results: The mean and standard deviation of fracture strength were 2108.6±440.1 N in full contour zirconia, and 3499.9±1106.5 N in pre-sintered Co-Cr alloy. According to Mann-Whitney U test, the difference in this respect was statistically significant between the two groups (P=0.007).

Conclusions: Since the fracture strength values obtained in the two groups were significantly higher than the maximum mean masticatory load in the oral environment, both materials can be used for fabrication of posterior three-unit FPDs, depending on the esthetic demands of patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
期刊最新文献
Polymerization Shrinkage of Five Bulk-Fill Composite Resins in Comparison with a Conventional Composite Resin. Effect of Storage Time of a Ceramic Primer on Microshear Bond Strength to Zirconia. Evaluation of the Effect of MTAD on Expression of Enterococcus faecalis Virulence Factors Considering the Role of Different Obturating Materials. Extraskeletal Ewing Sarcoma: Report of an Extremely Rare Case in Temporal Region. Evaluation of the Prevalence of Temporomandibular Joint Involvement in Rheumatoid Arthritis Using Research Diagnostic Criteria for Temporomandibular Disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1