Yukiko Mizutani, Norio Tada, Takahiko Masuda, Masaki Hata
{"title":"经导管同时介入治疗主动脉及二尖瓣缩窄。","authors":"Yukiko Mizutani, Norio Tada, Takahiko Masuda, Masaki Hata","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Coarctation of the aorta (CoA) is a relatively common congenital heart anomaly, and bicuspid aortic valve (BAV) is a common congenital heart disease that coexists with CoA. In larger children and adults with CoA, transcatheter intervention has gained acceptance, but for surgical high-risk patients with aortic stenosis, the use of transcatheter aortic valve implantation (TAVI) has been established. Recently, although favorable data have been reported for TAVI when treating BAV, simultaneous transcatheter intervention for CoA and BAV will prove to be a challenge because of the unique anatomy involved requires multiple procedural steps and also has problems of site access. Herein is reported a successful case of simultaneous thoracic endovascular repair (TEVAR) for CoA and transfemoral TAVI for congenital BAV dysfunction. A 62-year-old male with CoA and congenital BAV with severe aortic stenosis and aortic regurgitation had NYHA class IV heart failure symptoms. Because of the patient's extremely poor left ventricular function, the authors' heart team decided to perform simultaneous TEVAR for CoA and transfemoral TAVI. After deployment of a 32 mm stent graft, a 29 mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) was successfully deployed through the stent graft. This resulted in no significant pressure gradient within the aorta, and no aortic regurgitation. Video 1: Cineradiography showing delivery of the Edwards Commander delivery system through the stent graft. Video 2: Final aortography showing no residual aortic regurgitation.</p>","PeriodicalId":50184,"journal":{"name":"Journal of Heart Valve Disease","volume":"26 4","pages":"481-484"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Transcatheter Intervention for Coarctation of the Aorta and Bicuspid Aortic Valve.\",\"authors\":\"Yukiko Mizutani, Norio Tada, Takahiko Masuda, Masaki Hata\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Coarctation of the aorta (CoA) is a relatively common congenital heart anomaly, and bicuspid aortic valve (BAV) is a common congenital heart disease that coexists with CoA. In larger children and adults with CoA, transcatheter intervention has gained acceptance, but for surgical high-risk patients with aortic stenosis, the use of transcatheter aortic valve implantation (TAVI) has been established. Recently, although favorable data have been reported for TAVI when treating BAV, simultaneous transcatheter intervention for CoA and BAV will prove to be a challenge because of the unique anatomy involved requires multiple procedural steps and also has problems of site access. Herein is reported a successful case of simultaneous thoracic endovascular repair (TEVAR) for CoA and transfemoral TAVI for congenital BAV dysfunction. A 62-year-old male with CoA and congenital BAV with severe aortic stenosis and aortic regurgitation had NYHA class IV heart failure symptoms. Because of the patient's extremely poor left ventricular function, the authors' heart team decided to perform simultaneous TEVAR for CoA and transfemoral TAVI. After deployment of a 32 mm stent graft, a 29 mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) was successfully deployed through the stent graft. This resulted in no significant pressure gradient within the aorta, and no aortic regurgitation. Video 1: Cineradiography showing delivery of the Edwards Commander delivery system through the stent graft. Video 2: Final aortography showing no residual aortic regurgitation.</p>\",\"PeriodicalId\":50184,\"journal\":{\"name\":\"Journal of Heart Valve Disease\",\"volume\":\"26 4\",\"pages\":\"481-484\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Heart Valve Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart Valve Disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
主动脉缩窄(CoA)是一种较为常见的先天性心脏异常,双尖瓣主动脉瓣(BAV)是一种常见的与CoA并存的先天性心脏病。对于较大的CoA儿童和成人,经导管介入治疗已被接受,但对于手术高危的主动脉瓣狭窄患者,经导管主动脉瓣植入术(TAVI)已被确立。最近,尽管TAVI在治疗BAV时有良好的数据报道,但由于涉及独特的解剖结构,需要多个程序步骤,并且存在进入部位的问题,因此同时经导管介入CoA和BAV将被证明是一个挑战。本文报道一例成功的同时胸椎血管内修复术(TEVAR)治疗CoA和经股动脉TAVI治疗先天性BAV功能障碍。一例62岁男性CoA合并先天性BAV合并严重主动脉瓣狭窄和主动脉反流,出现NYHA IV级心力衰竭症状。由于患者左心室功能极差,作者的心脏团队决定同时对CoA和经股TAVI进行TEVAR。放置32mm支架后,通过支架成功放置29mm SAPIEN 3瓣膜(Edwards Lifesciences, Irvine, CA, USA)。这导致主动脉内没有明显的压力梯度,也没有主动脉反流。视频1:x线摄影显示Edwards Commander输送系统通过支架的输送。视频2:最终主动脉造影显示无残余主动脉反流。
Simultaneous Transcatheter Intervention for Coarctation of the Aorta and Bicuspid Aortic Valve.
Coarctation of the aorta (CoA) is a relatively common congenital heart anomaly, and bicuspid aortic valve (BAV) is a common congenital heart disease that coexists with CoA. In larger children and adults with CoA, transcatheter intervention has gained acceptance, but for surgical high-risk patients with aortic stenosis, the use of transcatheter aortic valve implantation (TAVI) has been established. Recently, although favorable data have been reported for TAVI when treating BAV, simultaneous transcatheter intervention for CoA and BAV will prove to be a challenge because of the unique anatomy involved requires multiple procedural steps and also has problems of site access. Herein is reported a successful case of simultaneous thoracic endovascular repair (TEVAR) for CoA and transfemoral TAVI for congenital BAV dysfunction. A 62-year-old male with CoA and congenital BAV with severe aortic stenosis and aortic regurgitation had NYHA class IV heart failure symptoms. Because of the patient's extremely poor left ventricular function, the authors' heart team decided to perform simultaneous TEVAR for CoA and transfemoral TAVI. After deployment of a 32 mm stent graft, a 29 mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) was successfully deployed through the stent graft. This resulted in no significant pressure gradient within the aorta, and no aortic regurgitation. Video 1: Cineradiography showing delivery of the Edwards Commander delivery system through the stent graft. Video 2: Final aortography showing no residual aortic regurgitation.
期刊介绍:
The Journal of Heart Valve Disease (ISSN 0966-8519) is the official journal of The Society for Heart Valve Disease. It is indexed/abstracted by Index Medicus, Medline, Medlar, PubMed, Science Citation Index, Scisearch, Research Alert, Biomedical Products, Current Contents/Clinical Medicine. It is issued bi-monthly in one indexed volume by ICR Publishers Ltd., Crispin House, 12A South Approach, Moor Park, Northwood HA6 2ET, United Kingdom. This paper meets the requirements of ANSI standard Z39.48-1992 (Permanence of Paper).