Alice Wang, Asvin M Ganapathi, Andrew Wang, G Chad Hughes
{"title":"改良罗斯手术与假体移植物包裹不能防止自体移植物失败。","authors":"Alice Wang, Asvin M Ganapathi, Andrew Wang, G Chad Hughes","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The modified Ross procedure, which involves replacement of the aortic valve with a pulmonary autograft root supported within a Dacron tube graft, was developed with the goal of preventing late autograft dilatation and associated aortic insufficiency. The case is reported of an adult patient who had a bicuspid aortic valve (BAV), underwent a modified Ross procedure, and developed severe aortic insufficiency within one year and subsequently required reoperation for aortic valve replacement. While advances have been made to increase the success of the Ross procedure via modifications to prevent aortic root dilatation, no modifications have yet been devised to improve the ability of the pulmonary valve to withstand systemic aortic pressures. The Ross procedure has significant advantages for children, but the risks and benefits should be carefully considered in adults, especially in those with BAV.</p>","PeriodicalId":50184,"journal":{"name":"Journal of Heart Valve Disease","volume":"26 6","pages":"735-737"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure.\",\"authors\":\"Alice Wang, Asvin M Ganapathi, Andrew Wang, G Chad Hughes\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The modified Ross procedure, which involves replacement of the aortic valve with a pulmonary autograft root supported within a Dacron tube graft, was developed with the goal of preventing late autograft dilatation and associated aortic insufficiency. The case is reported of an adult patient who had a bicuspid aortic valve (BAV), underwent a modified Ross procedure, and developed severe aortic insufficiency within one year and subsequently required reoperation for aortic valve replacement. While advances have been made to increase the success of the Ross procedure via modifications to prevent aortic root dilatation, no modifications have yet been devised to improve the ability of the pulmonary valve to withstand systemic aortic pressures. The Ross procedure has significant advantages for children, but the risks and benefits should be carefully considered in adults, especially in those with BAV.</p>\",\"PeriodicalId\":50184,\"journal\":{\"name\":\"Journal of Heart Valve Disease\",\"volume\":\"26 6\",\"pages\":\"735-737\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Heart Valve Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart Valve Disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure.
The modified Ross procedure, which involves replacement of the aortic valve with a pulmonary autograft root supported within a Dacron tube graft, was developed with the goal of preventing late autograft dilatation and associated aortic insufficiency. The case is reported of an adult patient who had a bicuspid aortic valve (BAV), underwent a modified Ross procedure, and developed severe aortic insufficiency within one year and subsequently required reoperation for aortic valve replacement. While advances have been made to increase the success of the Ross procedure via modifications to prevent aortic root dilatation, no modifications have yet been devised to improve the ability of the pulmonary valve to withstand systemic aortic pressures. The Ross procedure has significant advantages for children, but the risks and benefits should be carefully considered in adults, especially in those with BAV.
期刊介绍:
The Journal of Heart Valve Disease (ISSN 0966-8519) is the official journal of The Society for Heart Valve Disease. It is indexed/abstracted by Index Medicus, Medline, Medlar, PubMed, Science Citation Index, Scisearch, Research Alert, Biomedical Products, Current Contents/Clinical Medicine. It is issued bi-monthly in one indexed volume by ICR Publishers Ltd., Crispin House, 12A South Approach, Moor Park, Northwood HA6 2ET, United Kingdom. This paper meets the requirements of ANSI standard Z39.48-1992 (Permanence of Paper).