即刻加载3个(固定-3)与4个(固定-4)种植体支持交叉弓固定假体:1年多中心随机对照试验结果

Q1 Dentistry European Journal of Oral Implantology Pub Date : 2018-01-01
Gioacchino Cannizzaro, Marco Cavallari, Matteo Lazzarini, Giuseppe Purello D'ambrosio, Gianluigi Scialpi, Salvatore Audino, Eugenio Velasco-Ortega, Daniela Rita Ippolito, Marco Esposito
{"title":"即刻加载3个(固定-3)与4个(固定-4)种植体支持交叉弓固定假体:1年多中心随机对照试验结果","authors":"Gioacchino Cannizzaro,&nbsp;Marco Cavallari,&nbsp;Matteo Lazzarini,&nbsp;Giuseppe Purello D'ambrosio,&nbsp;Gianluigi Scialpi,&nbsp;Salvatore Audino,&nbsp;Eugenio Velasco-Ortega,&nbsp;Daniela Rita Ippolito,&nbsp;Marco Esposito","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the outcome of three (fixed-on-3 = Fo3) vs four (fixed-on-4 = Fo4) implants immediately restored with metal-resin screw-retained cross-arch prostheses in fully edentulous jaws.</p><p><strong>Materials and methods: </strong>Forty-eight edentulous or to be rendered edentulous patients were randomised in six centres (eight patients per centre) to the Fo3 group (24 patients: 12 maxillae and 12 mandibles) and to the Fo4 group (24 patients: 12 maxillae and 12 mandibles) according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone level changes evaluated up to 1 year post-loading.</p><p><strong>Results: </strong>One maxillary prosthesis per group was delayed loaded because implants could not be placed with a torque of at least 40 Ncm. Ten patients in the Fo3 group and four in the Fo4 group had implants placed flapless. One year after loading no drop out occurred. One patient of the Fo3 group lost three implants vs three patients of the Fo4 group who lost four implants, the difference being no statistically significant (risk difference = -0.08; 95% CI: -0.27 to 0.10; Fisher's exact test P = 0.609). One mandibular Fo3 and one maxillary Fo4 prosthesis failed. Six Fo3 patients were affected by complications vs three Fo4 patients (risk difference = 0.12; 95% CI: -0.10 to 0.34; Fisher's exact test; P = 0.461). Both groups lost marginal bone in a statistically significant way (0.22 ± 0.20 mm for Fo3 patients and 0.40 ± 0.21 mm for Fo4 patients), with Fo3 group showing less marginal peri-implant bone loss than Fo4 group (estimate of the difference = -0.18 (standard error: 0.06) mm; 95% CI: -0.30 to -0.06; P = 0.005). There were no differences in clinical outcomes between the six operators.</p><p><strong>Conclusions: </strong>These preliminary results suggest that immediately loaded cross-arch prostheses of both jaws can be supported by only three dental implants at least up to 1 year post-loading, though longer follow-ups are definitively needed.</p>","PeriodicalId":49259,"journal":{"name":"European Journal of Oral Implantology","volume":"11 3","pages":"323-333"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Immediate loading of three (fixed-on-3) vs four (fixed-on-4) implants supporting cross-arch fixed prostheses: 1-year results from a multicentre randomised controlled trial.\",\"authors\":\"Gioacchino Cannizzaro,&nbsp;Marco Cavallari,&nbsp;Matteo Lazzarini,&nbsp;Giuseppe Purello D'ambrosio,&nbsp;Gianluigi Scialpi,&nbsp;Salvatore Audino,&nbsp;Eugenio Velasco-Ortega,&nbsp;Daniela Rita Ippolito,&nbsp;Marco Esposito\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the outcome of three (fixed-on-3 = Fo3) vs four (fixed-on-4 = Fo4) implants immediately restored with metal-resin screw-retained cross-arch prostheses in fully edentulous jaws.</p><p><strong>Materials and methods: </strong>Forty-eight edentulous or to be rendered edentulous patients were randomised in six centres (eight patients per centre) to the Fo3 group (24 patients: 12 maxillae and 12 mandibles) and to the Fo4 group (24 patients: 12 maxillae and 12 mandibles) according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone level changes evaluated up to 1 year post-loading.</p><p><strong>Results: </strong>One maxillary prosthesis per group was delayed loaded because implants could not be placed with a torque of at least 40 Ncm. Ten patients in the Fo3 group and four in the Fo4 group had implants placed flapless. One year after loading no drop out occurred. One patient of the Fo3 group lost three implants vs three patients of the Fo4 group who lost four implants, the difference being no statistically significant (risk difference = -0.08; 95% CI: -0.27 to 0.10; Fisher's exact test P = 0.609). One mandibular Fo3 and one maxillary Fo4 prosthesis failed. Six Fo3 patients were affected by complications vs three Fo4 patients (risk difference = 0.12; 95% CI: -0.10 to 0.34; Fisher's exact test; P = 0.461). Both groups lost marginal bone in a statistically significant way (0.22 ± 0.20 mm for Fo3 patients and 0.40 ± 0.21 mm for Fo4 patients), with Fo3 group showing less marginal peri-implant bone loss than Fo4 group (estimate of the difference = -0.18 (standard error: 0.06) mm; 95% CI: -0.30 to -0.06; P = 0.005). There were no differences in clinical outcomes between the six operators.</p><p><strong>Conclusions: </strong>These preliminary results suggest that immediately loaded cross-arch prostheses of both jaws can be supported by only three dental implants at least up to 1 year post-loading, though longer follow-ups are definitively needed.</p>\",\"PeriodicalId\":49259,\"journal\":{\"name\":\"European Journal of Oral Implantology\",\"volume\":\"11 3\",\"pages\":\"323-333\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Oral Implantology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Implantology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价全无牙颌即刻使用金属-树脂螺钉保留交叉弓修复体修复3(固定-3 = Fo3)与4(固定-4 = Fo4)种植体的效果。材料与方法:48例无牙或待修复无牙患者按平行组设计随机分为6个中心(每个中心8例患者),Fo3组(24例患者:12个上颌和12个下颌骨)和Fo4组(24例患者:12个上颌和12个下颌骨)。为了立即加载,植入物必须以最小40 Ncm的扭矩插入。结果测量假体和种植体失败,并发症和种植体周围边缘骨水平变化评估至加载后1年。结果:由于种植体不能以至少40 Ncm的扭矩放置,每组有1个上颌假体延迟加载。Fo3组10例,Fo4组4例无瓣种植体。加载一年后,没有出现退学现象。Fo3组1例患者丢失3个种植体,Fo4组3例患者丢失4个种植体,差异无统计学意义(风险差= -0.08;95% CI: -0.27 ~ 0.10;费雪精确检验P = 0.609)。1个下颌Fo3假体和1个上颌Fo4假体失败。6例Fo3患者发生并发症,3例Fo4患者发生并发症(风险差异= 0.12;95% CI: -0.10 ~ 0.34;费雪精确检验;P = 0.461)。两组边缘骨损失均有统计学意义(Fo3组为0.22±0.20 mm, Fo4组为0.40±0.21 mm), Fo3组种植体周围边缘骨损失小于Fo4组(差异估计= -0.18(标准误差:0.06)mm;95% CI: -0.30 ~ -0.06;P = 0.005)。6位手术者的临床结果无差异。结论:这些初步结果表明,即刻加载的双颌交叉弓修复体在加载后至少1年内可以仅由三颗种植体支撑,但肯定需要更长时间的随访。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Immediate loading of three (fixed-on-3) vs four (fixed-on-4) implants supporting cross-arch fixed prostheses: 1-year results from a multicentre randomised controlled trial.

Purpose: To evaluate the outcome of three (fixed-on-3 = Fo3) vs four (fixed-on-4 = Fo4) implants immediately restored with metal-resin screw-retained cross-arch prostheses in fully edentulous jaws.

Materials and methods: Forty-eight edentulous or to be rendered edentulous patients were randomised in six centres (eight patients per centre) to the Fo3 group (24 patients: 12 maxillae and 12 mandibles) and to the Fo4 group (24 patients: 12 maxillae and 12 mandibles) according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone level changes evaluated up to 1 year post-loading.

Results: One maxillary prosthesis per group was delayed loaded because implants could not be placed with a torque of at least 40 Ncm. Ten patients in the Fo3 group and four in the Fo4 group had implants placed flapless. One year after loading no drop out occurred. One patient of the Fo3 group lost three implants vs three patients of the Fo4 group who lost four implants, the difference being no statistically significant (risk difference = -0.08; 95% CI: -0.27 to 0.10; Fisher's exact test P = 0.609). One mandibular Fo3 and one maxillary Fo4 prosthesis failed. Six Fo3 patients were affected by complications vs three Fo4 patients (risk difference = 0.12; 95% CI: -0.10 to 0.34; Fisher's exact test; P = 0.461). Both groups lost marginal bone in a statistically significant way (0.22 ± 0.20 mm for Fo3 patients and 0.40 ± 0.21 mm for Fo4 patients), with Fo3 group showing less marginal peri-implant bone loss than Fo4 group (estimate of the difference = -0.18 (standard error: 0.06) mm; 95% CI: -0.30 to -0.06; P = 0.005). There were no differences in clinical outcomes between the six operators.

Conclusions: These preliminary results suggest that immediately loaded cross-arch prostheses of both jaws can be supported by only three dental implants at least up to 1 year post-loading, though longer follow-ups are definitively needed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Oral Implantology
European Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.35
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Immediate loading of fixed prostheses in fully edentulous jaws - 1-year follow-up from a single-cohort retrospective study. Research in focus. Dental implants with internal versus external connections: 1-year post-loading results from a pragmatic multicenter randomised controlled trial. Research in focus. Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1